A novel tool for in vivo dosimetry in diagnostic and interventional radiology using plastic scintillation detectors

被引:5
|
作者
Boivin, J. [1 ,2 ,3 ]
Beddar, S. [4 ]
Guillemette, M. [2 ,3 ,5 ]
Beaulieu, L. [1 ,2 ,3 ]
机构
[1] CHU Quebec, Dept Radiooncol & Axe Oncol, Ctr Rech, Quebec City, PQ, Canada
[2] Univ Laval, Dept Phys Genie Phys & Opt, Quebec City, PQ, Canada
[3] Univ Laval, Ctr Rech Canc, Quebec City, PQ, Canada
[4] Univ Texas MD Anderson Canc Ctr, Houston, TX 77030 USA
[5] Inst Univ Cardiol & Pneumol Quebec, Quebec City, PQ, Canada
关键词
PSD; plastic scintillation detector; dosimetry; photodetector; interventional radiology;
D O I
10.1007/978-3-319-19387-8_167
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A plastic scintillation detector (PSD) has been developed and optimized to measure dose rate in real-time for low energy beams. The PSD is composed of a scintillating fiber coupled to a clear optical fiber transmitting the scintillator's light to a photodetector. A spectrometer was used to characterize the scintillator's spectrum under low and high energy exposures. Seven photodetectors were then evaluated to identify their operating range and potential applications. They comprise a photomultiplier tube (PMT), an avalanche photodiode, two passive diodes of which, and a set of three CCD cameras. The scintillator was exposed to low energy potential beams (120 kVp, 180 kVp, and 220 kVp) of an orthovoltage unit. The source-to-detector distance was varied to explore a broad dose rate range likely to be used in radiology and superficial treatment. Every detector could measure dose rate down to 10 mGy/s while keeping a relative standard deviation below 2 %. The CCD cameras were the less sensitive devices, but they allow multiple fibers to be read simultaneously. Among the photodetectors, the PMT was found to be the most sensitive detector with a relative standard deviation of less than 1 % at the lowest dose rate available. The PMT was then included in the PSD design for an in vivo study in interventional radiology where low dose rate sensitivity is essential. The PSD was located inside a plastic water phantom to measure skin and depth dose from 1 mm down to 24 cm. There was less than a 2 % difference between the PSD measured dose rate and the ion chamber reading located at the same depth. These results indicate that a broad range of photodetectors can be used in the PSD design, but low dose rate measurements require very sensitive devices such as a PMT.
引用
收藏
页码:680 / 684
页数:5
相关论文
共 50 条
  • [21] HZE dosimetry in space using plastic track detectors
    Kopp, J
    Beaujean, R
    Reitz, G
    Enge, W
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 573 - 578
  • [22] HZE dosimetry in space using plastic track detectors
    Institut für Experimentelle und Angewandte Physik, Universität Kiel, Olshausenstr.40/60, 24118 Kiel, Germany
    不详
    Radiat. Meas., 1 (573-578):
  • [23] RADON DOSIMETRY USING PLASTIC NUCLEAR TRACK DETECTORS
    FRANK, AL
    BENTON, EV
    NUCLEAR TRACK DETECTION, 1977, 1 (3-4): : 149 - 179
  • [24] A simple calibration routine for small inorganic scintillation detectors for in vivo dosimetry during brachytherapy
    Georgi, Peter D.
    Jorgensen, Erik B.
    Heidotting, Marjolein
    Tanderup, Kari
    Kertzscher, Gustavo
    Johansen, Jacob G.
    BRACHYTHERAPY, 2024, 23 (05) : 514 - 522
  • [25] Alpha/beta pulse shape discrimination in plastic scintillation using commercial scintillation detectors
    Bagan, H.
    Tarancon, A.
    Rauret, G.
    Garcia, J. F.
    ANALYTICA CHIMICA ACTA, 2010, 670 (1-2) : 11 - 17
  • [26] In-Vivo Dosimetry Using Aluminum Oxide Detectors
    Danzer, J.
    Harris, C.
    Usynin, A.
    Ramsey, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [27] Technical Note: Removing the stem effect when performing Ir-192 HDR brachytherapy in vivo dosimetry using plastic scintillation detectors: A relevant and necessary step
    Therriault-Proulx, Francois
    Beddar, Sam
    Briere, Tina M.
    Archambault, Louis
    Beaulieu, Luc
    MEDICAL PHYSICS, 2011, 38 (04) : 2176 - 2179
  • [28] PSD (plastic scintillation detector) in vivo dosimetry in post-operative endometrial brachytherapy
    Herreros, A.
    Melo, J.
    Moutinho, L.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1606 - S1607
  • [29] The ICRU (International Commission on Radiation Units and Measurements): Its contribution to dosimetry in diagnostic and interventional radiology
    Wambersie, A
    Zoetelief, J
    Menzel, HG
    Paretzke, H
    RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) : 7 - 12
  • [30] A feasibility study of novel plastic scintillation dosimetry with pulse-counting mode
    Ishikawa, M.
    Bengua, G.
    Sutherland, K. L.
    Hiratsuka, J.
    Katoh, N.
    Shimizu, S.
    Aoyama, H.
    Fujita, K.
    Yamazaki, R.
    Horita, K.
    Shirato, H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (07): : 2079 - 2092