A novel tool for in vivo dosimetry in diagnostic and interventional radiology using plastic scintillation detectors

被引:5
|
作者
Boivin, J. [1 ,2 ,3 ]
Beddar, S. [4 ]
Guillemette, M. [2 ,3 ,5 ]
Beaulieu, L. [1 ,2 ,3 ]
机构
[1] CHU Quebec, Dept Radiooncol & Axe Oncol, Ctr Rech, Quebec City, PQ, Canada
[2] Univ Laval, Dept Phys Genie Phys & Opt, Quebec City, PQ, Canada
[3] Univ Laval, Ctr Rech Canc, Quebec City, PQ, Canada
[4] Univ Texas MD Anderson Canc Ctr, Houston, TX 77030 USA
[5] Inst Univ Cardiol & Pneumol Quebec, Quebec City, PQ, Canada
关键词
PSD; plastic scintillation detector; dosimetry; photodetector; interventional radiology;
D O I
10.1007/978-3-319-19387-8_167
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A plastic scintillation detector (PSD) has been developed and optimized to measure dose rate in real-time for low energy beams. The PSD is composed of a scintillating fiber coupled to a clear optical fiber transmitting the scintillator's light to a photodetector. A spectrometer was used to characterize the scintillator's spectrum under low and high energy exposures. Seven photodetectors were then evaluated to identify their operating range and potential applications. They comprise a photomultiplier tube (PMT), an avalanche photodiode, two passive diodes of which, and a set of three CCD cameras. The scintillator was exposed to low energy potential beams (120 kVp, 180 kVp, and 220 kVp) of an orthovoltage unit. The source-to-detector distance was varied to explore a broad dose rate range likely to be used in radiology and superficial treatment. Every detector could measure dose rate down to 10 mGy/s while keeping a relative standard deviation below 2 %. The CCD cameras were the less sensitive devices, but they allow multiple fibers to be read simultaneously. Among the photodetectors, the PMT was found to be the most sensitive detector with a relative standard deviation of less than 1 % at the lowest dose rate available. The PMT was then included in the PSD design for an in vivo study in interventional radiology where low dose rate sensitivity is essential. The PSD was located inside a plastic water phantom to measure skin and depth dose from 1 mm down to 24 cm. There was less than a 2 % difference between the PSD measured dose rate and the ion chamber reading located at the same depth. These results indicate that a broad range of photodetectors can be used in the PSD design, but low dose rate measurements require very sensitive devices such as a PMT.
引用
收藏
页码:680 / 684
页数:5
相关论文
共 50 条
  • [41] Individual monitoring of medical staff working in interventional radiology in Switzerland using double dosimetry
    Damet, J.
    Bailat, C.
    Bize, P.
    Buchillier, Th.
    Tosic, M.
    Verdun, F. R.
    Baechler, S.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1839 - 1842
  • [42] Patient dosimetry and a novel approach to establishing Diagnostic Reference Levels in dental radiology
    Walker, Christopher
    van der Putten, Wit
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (01): : 7 - 12
  • [43] In Vivo Skin Dosimetry Using the Exradin W1 Plastic Scintillation Detector for Passively Scattered Proton Beam Therapy
    Alsanea, F.
    Wootton, L.
    Kudchadker, R.
    Usama, M.
    Beddar, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3446 - 3446
  • [44] Real-Time In-Vivo Dosimetry Using Plastic Scintillation Detector (PSD) Device While Treating Prostate with EBRT
    Baig, T.
    Muenkel, J.
    Xu, K.
    Xu, Z.
    Podder, T.
    Ellis, R.
    MEDICAL PHYSICS, 2019, 46 (06) : E203 - E203
  • [45] Simulation of the precision limits of plastic scintillation detectors using optimal component selection
    Lacroix, Frederic
    Beaulieu, Luc
    Archambault, Louis
    Beddar, A. Sam
    MEDICAL PHYSICS, 2010, 37 (02) : 412 - 418
  • [46] In vivo endorectal dosimetry of prostate tomotherapy using dual MOSkin detectors
    Alnaghy, Sarah J.
    Deshpande, Shrikant
    Cutajar, Dean L.
    Berk, Kemal
    Metcalfe, Peter
    Rosenfeld, Anatoly B.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 107 - 117
  • [47] A Novel Electromagnetic-Tracked Scintillation Dosimeter for Accurate in Vivo Dosimetry in HDR Brachytherapy
    Tho, D.
    Beaulieu, L.
    MEDICAL PHYSICS, 2018, 45 (06) : E172 - E172
  • [48] A Novel Electromagnetic-Tracked Scintillation Dosimeter for Accurate In Vivo Dosimetry in HDR Brachytherapy
    Tho, D.
    Beaulieu, L.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [49] TEMPERATURE-RELATED EFFECTS IN RADON DOSIMETRY USING PLASTIC TRACK DETECTORS
    HASHEMINEZHAD, SR
    PEAK, LS
    BAKICH, AM
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1992, 20 (04): : 575 - 581
  • [50] WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .2. PROPERTIES AND MEASUREMENTS
    BEDDAR, AS
    MACKIE, TR
    ATTIX, FH
    PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10): : 1901 - 1913