Patient dosimetry and a novel approach to establishing Diagnostic Reference Levels in dental radiology

被引:10
|
作者
Walker, Christopher [1 ]
van der Putten, Wit [1 ,2 ]
机构
[1] St Lukes Hosp, Dept Phys, Dublin 6, Ireland
[2] Natl Univ Ireland, Sch Phys, Galway, Ireland
来源
关键词
Diagnostic Reference Levels; Dental X-ray units; Quality Assurance; Monte-Carlo; Intra-Oral; Pan-oral tomograph;
D O I
10.1016/j.ejmp.2010.12.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Diagnostic Reference Levels provide a method of ensuring that patient doses in medical procedures are kept at acceptable levels. Their application in dentistry can provide an indication of current dose levels and can assist in potentially significant dose reduction in Ireland given the number of patients screened annually. This study involved retrospective analyses of entrance surface dose and dose-width-product measurements obtained in Irish Dental Practices for both Intra-Oral and Panoramic units respectively, followed by comparisons with Monte-Carlo generated computer models of these procedures. Analysis was performed on data from 33 Intra-Oral units for an Adult Mandibular Molar entrance surface dose, 198 readings for a proposed mGy/mAs reference level and 50 Panoramic machines for a dose-width product investigation. The third quartile value of the entrance surface dose for a standard Adult Mandibular Molar Intra-Oral radiograph is (2.40 +/- 0.92)mGy, compared to a computer-modelled value of 2.60 mGy. The third quartile mGy/mAs value for Intra-Oral procedures is (1.03 +/- 0.38)mGy/mAs, compared to a computer-modelled value of 0.75 mGy/mAs. The third quartile dose width product for an Adult Panoramic radiograph is (59.89 +/- 20.97)mGymm, compared to a computer-modeled value of 62.40 mGymm. It is proposed to introduce Diagnostic Reference Levels of 2.4 mGy for an Adult Mandibular Molar Intra-Oral radiograph and 60 mGymm for an Adult Panoramic radiograph. The use of a new reference quantity in Intra-Oral radiology is also suggested. This has a value of 1 mGy/mAs and may be introduced alongside established procedures. These levels can be taken as guides to acceptable doses, but it should be noted that further reductions are practical under ALARA principles. (C) 2010 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 50 条
  • [1] Patient dosimetry audit for establishing local diagnostic reference levels for nuclear medicine CT
    Gardner, Matthew
    Katsidzira, Ngonidzashe M.
    Ross, Erin
    Larkin, Elizabeth A.
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1071):
  • [2] Patient dosimetry in diagnostic and interventional radiology: A practical approach using trigger levels
    Faulkner, K
    Ortiz-Lopez, P
    Vano, E
    RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) : 166 - 168
  • [3] An approach to diagnostic radiology dosimetry
    Donald McLean
    Australasian Physical & Engineering Sciences in Medicine, 2014, 37 : 615 - 618
  • [4] An approach to diagnostic radiology dosimetry
    McLean, Donald
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2014, 37 (04) : 615 - 618
  • [5] Patient dosimetry in paediatric diagnostic radiology
    Borisova, R.
    Ingilizova, Ch.
    Vassileva, J.
    RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 155 - 159
  • [6] THE REFERENCE MAN IN DIAGNOSTIC-RADIOLOGY DOSIMETRY
    LINDSKOUG, BA
    BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (773): : 431 - 437
  • [7] REFERENCE MAN IN DIAGNOSTIC-RADIOLOGY DOSIMETRY
    LINDSKOUG, BA
    RADIATION PROTECTION DOSIMETRY, 1992, 43 (1-4) : 111 - 114
  • [8] Approaches to establishing reference levels in interventional radiology
    Vañó, E
    Gonzalez, L
    RADIATION PROTECTION DOSIMETRY, 2001, 94 (1-2) : 109 - 112
  • [9] Approaches to establishing reference levels in interventional radiology
    Vañó, E
    Gonzalez, L
    DOSE AND IMAGE QUALITY IN DIGITAL IMAGING AND INTERVENTIONAL RADIOLOGY (DIMOND), 2001, : 109 - 112
  • [10] Patient Dose Measurements for Establishing Guidance Levels for Medical Exposures in Diagnostic Radiology
    Duhaini, I.
    Assafiri, Y.
    El-Nachef, L.
    MEDICAL PHYSICS, 2008, 35 (06)