Patient dosimetry and a novel approach to establishing Diagnostic Reference Levels in dental radiology

被引:10
|
作者
Walker, Christopher [1 ]
van der Putten, Wit [1 ,2 ]
机构
[1] St Lukes Hosp, Dept Phys, Dublin 6, Ireland
[2] Natl Univ Ireland, Sch Phys, Galway, Ireland
来源
关键词
Diagnostic Reference Levels; Dental X-ray units; Quality Assurance; Monte-Carlo; Intra-Oral; Pan-oral tomograph;
D O I
10.1016/j.ejmp.2010.12.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Diagnostic Reference Levels provide a method of ensuring that patient doses in medical procedures are kept at acceptable levels. Their application in dentistry can provide an indication of current dose levels and can assist in potentially significant dose reduction in Ireland given the number of patients screened annually. This study involved retrospective analyses of entrance surface dose and dose-width-product measurements obtained in Irish Dental Practices for both Intra-Oral and Panoramic units respectively, followed by comparisons with Monte-Carlo generated computer models of these procedures. Analysis was performed on data from 33 Intra-Oral units for an Adult Mandibular Molar entrance surface dose, 198 readings for a proposed mGy/mAs reference level and 50 Panoramic machines for a dose-width product investigation. The third quartile value of the entrance surface dose for a standard Adult Mandibular Molar Intra-Oral radiograph is (2.40 +/- 0.92)mGy, compared to a computer-modelled value of 2.60 mGy. The third quartile mGy/mAs value for Intra-Oral procedures is (1.03 +/- 0.38)mGy/mAs, compared to a computer-modelled value of 0.75 mGy/mAs. The third quartile dose width product for an Adult Panoramic radiograph is (59.89 +/- 20.97)mGymm, compared to a computer-modeled value of 62.40 mGymm. It is proposed to introduce Diagnostic Reference Levels of 2.4 mGy for an Adult Mandibular Molar Intra-Oral radiograph and 60 mGymm for an Adult Panoramic radiograph. The use of a new reference quantity in Intra-Oral radiology is also suggested. This has a value of 1 mGy/mAs and may be introduced alongside established procedures. These levels can be taken as guides to acceptable doses, but it should be noted that further reductions are practical under ALARA principles. (C) 2010 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 50 条
  • [41] Diagnostic reference levels in intraoral dental radiography in Korea
    Kim, Eun-Kyung
    Han, Won-Jeong
    Choi, Jin-Woo
    Jung, Yun-Hoa
    Yoon, Suk-Ja
    Lee, Jae-Seo
    IMAGING SCIENCE IN DENTISTRY, 2012, 42 (04) : 237 - 242
  • [42] Establishment of diagnostic reference levels for dental intraoral radiography
    Manousaridis, G.
    Koukorava, C.
    Hourdakis, C. J.
    Kamenopoulou, V.
    Yakoumakis, E.
    Tsiklakis, K.
    RADIATION PROTECTION DOSIMETRY, 2013, 156 (04) : 455 - 457
  • [43] Dose area product measurement for diagnostic reference levels and analysis of patient dose in dental radiography
    Han, Suchul
    Lee, Boram
    Shin, Gwisoon
    Choi, Jonghak
    Kim, Jungmin
    Park, Changseo
    Park, Hyok
    Lee, Kisung
    Kim, Youhyun
    RADIATION PROTECTION DOSIMETRY, 2012, 150 (04) : 523 - 531
  • [44] AN INSTRUMENT TO PERFORM AUTOMATED QUALITY ASSURANCE AND PATIENT DOSIMETRY IN DIAGNOSTIC-RADIOLOGY
    CHAPPLE, CL
    FAULKNER, K
    RADIATION PROTECTION DOSIMETRY, 1992, 43 (1-4) : 193 - 195
  • [45] Patient dosimetry in diagnostic radiology and dose measurement I practice - A pilot survey
    Ciraj, O
    Kosutic, D
    Markovic, S
    APPLIED PHYSICS IN SERBIA-APS, 2002, : 317 - 320
  • [46] Patient radiation doses and reference levels in pediatric interventional radiology
    Geryes, Bouchra Habib
    Bak, Adeline
    Lachaux, Julie
    Ozanne, Augustin
    Boddaert, Nathalie
    Brunelle, Francis
    Naggara, Olivier
    Saliou, Guillaume
    EUROPEAN RADIOLOGY, 2017, 27 (09) : 3983 - 3990
  • [47] Patient radiation doses and reference levels in pediatric interventional radiology
    Bouchra Habib Geryes
    Adeline Bak
    Julie Lachaux
    Augustin Ozanne
    Nathalie Boddaert
    Francis Brunelle
    Olivier Naggara
    Guillaume Saliou
    European Radiology, 2017, 27 : 3983 - 3990
  • [48] Diagnostic reference levels and complexity indices in interventional radiology: a national programme
    Ruiz-Cruces, R.
    Vano, E.
    Carrera-Magarino, F.
    Moreno-Rodriguez, F.
    Soler-Cantos, M. M.
    Canis-Lopez, M.
    Hernandez-Armas, J.
    Diaz-Romero, F. J.
    Rosales-Espizua, F.
    Fernandez-Soto, J. M.
    Sanchez-Casanueva, R.
    Martin-Palanca, A.
    Perez-Martinez, M.
    Gil-Agudo, A.
    Zarca-Diaz, M. A.
    Parra-Osorio, V.
    Munoz Ruiz-Canela, J. J.
    Moreno-Sanchez, T.
    Lopez-Medina, A.
    Moreno-Saiz, C.
    Galan-Montenegro, P.
    Gallego-Beuter, J. J.
    Gonzalez-de-Garay, M.
    Zapata-Jimenez, J. C.
    Pastor-Vega, J. M.
    Canete, S.
    EUROPEAN RADIOLOGY, 2016, 26 (12) : 4268 - 4276
  • [49] Image properly: Diagnostic reference levels and optimization in oral and maxillofacial radiology
    Geist, James R.
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2022, 133 (04): : 359 - 361
  • [50] Diagnostic reference levels and complexity indices in interventional radiology: a national programme
    R. Ruiz-Cruces
    E. Vano
    F. Carrera-Magariño
    F. Moreno-Rodriguez
    M. M. Soler-Cantos
    M. Canis-Lopez
    J. Hernández-Armas
    F. J. Diaz-Romero
    F. Rosales-Espizua
    J. M. Fernandez-Soto
    R. Sanchez-Casanueva
    A. Martin-Palanca
    M. Perez-Martinez
    A. Gil-Agudo
    M. A. Zarca-Diaz
    V. Parra-Osorio
    J. J. Muñoz Ruiz-Canela
    T. Moreno-Sanchez
    A. Lopez-Medina
    C. Moreno-Saiz
    P. Galan-Montenegro
    J. J. Gallego-Beuter
    M. Gonzalez-de-Garay
    J. C. Zapata-Jimenez
    J. M. Pastor-Vega
    S. Cañete
    European Radiology, 2016, 26 : 4268 - 4276