Patient dosimetry and a novel approach to establishing Diagnostic Reference Levels in dental radiology

被引:10
|
作者
Walker, Christopher [1 ]
van der Putten, Wit [1 ,2 ]
机构
[1] St Lukes Hosp, Dept Phys, Dublin 6, Ireland
[2] Natl Univ Ireland, Sch Phys, Galway, Ireland
来源
关键词
Diagnostic Reference Levels; Dental X-ray units; Quality Assurance; Monte-Carlo; Intra-Oral; Pan-oral tomograph;
D O I
10.1016/j.ejmp.2010.12.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Diagnostic Reference Levels provide a method of ensuring that patient doses in medical procedures are kept at acceptable levels. Their application in dentistry can provide an indication of current dose levels and can assist in potentially significant dose reduction in Ireland given the number of patients screened annually. This study involved retrospective analyses of entrance surface dose and dose-width-product measurements obtained in Irish Dental Practices for both Intra-Oral and Panoramic units respectively, followed by comparisons with Monte-Carlo generated computer models of these procedures. Analysis was performed on data from 33 Intra-Oral units for an Adult Mandibular Molar entrance surface dose, 198 readings for a proposed mGy/mAs reference level and 50 Panoramic machines for a dose-width product investigation. The third quartile value of the entrance surface dose for a standard Adult Mandibular Molar Intra-Oral radiograph is (2.40 +/- 0.92)mGy, compared to a computer-modelled value of 2.60 mGy. The third quartile mGy/mAs value for Intra-Oral procedures is (1.03 +/- 0.38)mGy/mAs, compared to a computer-modelled value of 0.75 mGy/mAs. The third quartile dose width product for an Adult Panoramic radiograph is (59.89 +/- 20.97)mGymm, compared to a computer-modeled value of 62.40 mGymm. It is proposed to introduce Diagnostic Reference Levels of 2.4 mGy for an Adult Mandibular Molar Intra-Oral radiograph and 60 mGymm for an Adult Panoramic radiograph. The use of a new reference quantity in Intra-Oral radiology is also suggested. This has a value of 1 mGy/mAs and may be introduced alongside established procedures. These levels can be taken as guides to acceptable doses, but it should be noted that further reductions are practical under ALARA principles. (C) 2010 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 50 条
  • [31] Patient dosimetry in diagnostic radiology - some practical considerations in an NHS Region
    Harrison, R.M.
    Faulkner, K.
    Davies, M.L.
    Chapple, C.L.
    Robson, K.J.
    Broadhead, D.A.
    Journal of Radiological Protection, 1995, 15 (03)
  • [32] Evaluation of physical performance of a scintillation dosemeter for patient dosimetry in diagnostic radiology
    De Sousa, MC
    Aubert, B
    Ricard, M
    BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (876): : 1297 - 1305
  • [33] A STUDY IN EUROPE OF PATIENT DOSIMETRY IN DIAGNOSTIC RADIOLOGY: PROTOCOL DEVELOPMENT AND FINDINGS
    Gfirtner, H.
    Kaplanis, P. A.
    Moores, B. M.
    Schneider, P.
    Vassileva, J.
    RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) : 380 - 387
  • [34] Overview of patient dosimetry in diagnostic radiology in the USA for the past 50 years
    Huda, Walter
    Nickoloff, Edward L.
    Boone, John M.
    MEDICAL PHYSICS, 2008, 35 (12) : 5713 - 5728
  • [35] An Approach to Establishing Diagnostic Reference Levels in Interventional Pediatric Cardiology from Different Regions of Brazil
    Asfora, Viviane K.
    Freitas, Marcelo B.
    Medeiros, Regina B.
    Schelin, Hugo R.
    Yagui, Akemi
    Oliveira, Marcus V. L.
    Leite, Luiz M. S. A.
    Lopez, Guillermo A.
    Roberto, Maryanna R. S.
    Gagetti, Fabio L.
    Souza, Pablo H. O.
    Vargas, Bruna
    Denyak, Valeriy V.
    Khoury, Helen J.
    CHILDREN-BASEL, 2024, 11 (02):
  • [36] ERPET training course: establishment of reference levels in diagnostic radiology
    Corbett, RH
    Faulkner, K
    Fong, R
    BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (876): : 1243 - 1245
  • [37] Establishment of Diagnostic Reference Levels in Portuguese Interventional Radiology departments
    Pimenta, Andrea
    Azevedo, Luis
    Ramos, Isabel
    Santos, Joana
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 173
  • [38] Nordic guidance levels for patient doses in diagnostic radiology
    Saxebol, G
    Olerud, HM
    Hjardemaal, O
    Leitz, W
    Servomaa, A
    Walderhaug, T
    RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 99 - 101
  • [39] OPTIMIZATION OF RADIATION DOSE IN CT IMAGING: ESTABLISHING THE INSTITUTIONAL DIAGNOSTIC REFERENCE LEVELS AND PATIENT DOSE AUDITING
    Razali, Mohd Amir Syahmi Mat
    Ahmad, Muhamad Zabidi
    Shuaib, Ibrahim Lutfi
    Osman, Noor Diyana
    RADIATION PROTECTION DOSIMETRY, 2020, 188 (02) : 213 - 221
  • [40] Diagnostic reference levels at intraoral and dental panoramic examinations
    Hodolli, G.
    Kadiri, S.
    Nafezi, G.
    Bahtijari, M.
    Syla, N.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2019, 17 (01): : 147 - 150