A novel tool for in vivo dosimetry in diagnostic and interventional radiology using plastic scintillation detectors

被引:5
|
作者
Boivin, J. [1 ,2 ,3 ]
Beddar, S. [4 ]
Guillemette, M. [2 ,3 ,5 ]
Beaulieu, L. [1 ,2 ,3 ]
机构
[1] CHU Quebec, Dept Radiooncol & Axe Oncol, Ctr Rech, Quebec City, PQ, Canada
[2] Univ Laval, Dept Phys Genie Phys & Opt, Quebec City, PQ, Canada
[3] Univ Laval, Ctr Rech Canc, Quebec City, PQ, Canada
[4] Univ Texas MD Anderson Canc Ctr, Houston, TX 77030 USA
[5] Inst Univ Cardiol & Pneumol Quebec, Quebec City, PQ, Canada
关键词
PSD; plastic scintillation detector; dosimetry; photodetector; interventional radiology;
D O I
10.1007/978-3-319-19387-8_167
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A plastic scintillation detector (PSD) has been developed and optimized to measure dose rate in real-time for low energy beams. The PSD is composed of a scintillating fiber coupled to a clear optical fiber transmitting the scintillator's light to a photodetector. A spectrometer was used to characterize the scintillator's spectrum under low and high energy exposures. Seven photodetectors were then evaluated to identify their operating range and potential applications. They comprise a photomultiplier tube (PMT), an avalanche photodiode, two passive diodes of which, and a set of three CCD cameras. The scintillator was exposed to low energy potential beams (120 kVp, 180 kVp, and 220 kVp) of an orthovoltage unit. The source-to-detector distance was varied to explore a broad dose rate range likely to be used in radiology and superficial treatment. Every detector could measure dose rate down to 10 mGy/s while keeping a relative standard deviation below 2 %. The CCD cameras were the less sensitive devices, but they allow multiple fibers to be read simultaneously. Among the photodetectors, the PMT was found to be the most sensitive detector with a relative standard deviation of less than 1 % at the lowest dose rate available. The PMT was then included in the PSD design for an in vivo study in interventional radiology where low dose rate sensitivity is essential. The PSD was located inside a plastic water phantom to measure skin and depth dose from 1 mm down to 24 cm. There was less than a 2 % difference between the PSD measured dose rate and the ion chamber reading located at the same depth. These results indicate that a broad range of photodetectors can be used in the PSD design, but low dose rate measurements require very sensitive devices such as a PMT.
引用
收藏
页码:680 / 684
页数:5
相关论文
共 50 条
  • [11] Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range
    Lessard, Francois
    Archambault, Louis
    Plamondon, Mathieu
    Despres, Philippe
    Therriault-Proulx, Francois
    Beddar, Sam
    Beaulieu, Luc
    MEDICAL PHYSICS, 2012, 39 (09) : 5308 - 5316
  • [12] Evaluation of physical performance of a scintillation dosemeter for patient dosimetry in diagnostic radiology
    De Sousa, MC
    Aubert, B
    Ricard, M
    BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (876): : 1297 - 1305
  • [13] Plastic Scintillation Detector Calibration Procedure for Brachytherapy in Vivo Dosimetry
    Herreros, A.
    Perez-Calatayud, J.
    Ballester, F.
    MEDICAL PHYSICS, 2020, 47 (06) : E473 - E473
  • [14] Patient dosimetry in interventional radiology using slow films
    Vano, E
    Guibelalde, E
    Fernandez, JM
    Gonzalez, L
    Ten, JI
    BRITISH JOURNAL OF RADIOLOGY, 1997, 70 : 195 - 200
  • [15] Experience With Patient Dosimetry and Quality Control Online for Diagnostic and Interventional Radiology Using DICOM Services
    Vano, Eliseo
    Ten, Jose I.
    Fernandez-Soto, Jose M.
    Sanchez-Casanueva, Roberto M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (04) : 783 - 790
  • [16] Intrinsic energy dependent response of inorganic scintillation detectors for in vivo dosimetry
    Georgi, P.
    Tedgren, A. Carlsson
    Persson, L.
    Johansen, J. Graversen
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S228 - S229
  • [17] A phantom study of an in vivo dosimetry system using plastic scintillation detectors for real-time verification of 192Ir HDR brachytherapy
    Therriault-Proulx, Francois
    Briere, Tina M.
    Mourtada, Firas
    Aubin, Sylviane
    Beddar, Sam
    Beaulieu, Luc
    MEDICAL PHYSICS, 2011, 38 (05) : 2542 - 2551
  • [18] In Phantom Full-Implant Validation of Plastic Scintillation Detectors for in Vivo Dosimetry During Low Dose Rate Brachytherapy
    Therriault-Proulx, F.
    Beaulieu, L.
    Bruno, T.
    Beddar, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3463 - 3463
  • [19] A high sensitivity plastic scintillation detector for in vivo dosimetry of LDR brachytherapy
    Therriault-Proulx, F.
    Beaulieu, L.
    Beddar, S.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S116 - S116
  • [20] Diagnostic radiology dosimetry using ionization chambers
    Albuquerque, MD
    Caldas, LVE
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 3, 1996, : C455 - C457