Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range

被引:43
|
作者
Lessard, Francois [1 ,2 ]
Archambault, Louis [1 ,2 ]
Plamondon, Mathieu [1 ,2 ]
Despres, Philippe [1 ,2 ]
Therriault-Proulx, Francois [1 ,2 ,3 ]
Beddar, Sam [3 ]
Beaulieu, Luc [1 ,2 ]
机构
[1] Univ Laval, Dept Phys Genie Phys & Opt, Quebec City, PQ G1K 7P4, Canada
[2] Univ Quebec, Ctr Hosp, Dept Radio Oncol, Quebec City, PQ G1R 2J6, Canada
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
基金
加拿大自然科学与工程研究理事会; 美国国家卫生研究院;
关键词
plastic scintillation detector; radiology; diagnostic radiology; dosimetry; X-RAY-SPECTRA; BEAM DOSIMETRY; DIAGNOSTIC-RADIOLOGY; SEMIEMPIRICAL MODEL; RADIATION-THERAPY; COUPLED DOSIMETER; OPTICAL-FIBERS; RADIOLUMINESCENCE; PERFORMANCE; SIMULATION;
D O I
10.1118/1.4738964
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Photon dosimetry in the kilovolt (kV) energy range represents a major challenge for diagnostic and interventional radiology and superficial therapy. Plastic scintillation detectors (PSDs) are potentially good candidates for this task. This study proposes a simple way to obtain accurate correction factors to compensate for the response of PSDs to photon energies between 80 and 150 kVp. The performance of PSDs is also investigated to determine their potential usefulness in the diagnostic energy range. Methods: A 1-mm-diameter, 10-mm-long PSD was irradiated by a Therapax SXT 150 unit using five different beam qualities made of tube potentials ranging from 80 to 150 kVp and filtration thickness ranging from 0.8 to 0.2 mmAl + 1.0 mmCu. The light emitted by the detector was collected using an 8-m-long optical fiber and a polychromatic photodiode, which converted the scintillation photons to an electrical current. The PSD response was compared with the reference free air dose rate measured with a calibrated Farmer NE2571 ionization chamber. PSD measurements were corrected using spectra-weighted corrections, accounting for mass energy-absorption coefficient differences between the sensitive volumes of the ionization chamber and the PSD, as suggested by large cavity theory (LCT). Beam spectra were obtained from x-ray simulation software and validated experimentally using a CdTe spectrometer. Correction factors were also obtained using Monte Carlo (MC) simulations. Percent depth dose (PDD) measurements were compensated for beam hardening using the LCT correction method. These PDD measurements were compared with uncorrected PSD data, PDD measurements obtained using Gafchromic films, Monte Carlo simulations, and previous data. Results: For each beam quality used, the authors observed an increase of the energy response with effective energy when no correction was applied to the PSD response. Using the LCT correction, the PSD response was almost energy independent, with a residual 2.1% coefficient of variation (COV) over the 80-150-kVp energy range. Monte Carlo corrections reduced the COV to 1.4% over this energy range. All PDD measurements were in good agreement with one another except for the uncorrected PSD data, in which an over-response was observed with depth (13% at 10 cm with a 100 kVp beam), showing that beam hardening had a non-negligible effect on the PSD response. A correction based on LCT compensated very well for this effect, reducing the over-response to 3%. Conclusion: In the diagnostic energy range, PSDs show high-energy dependence, which can be corrected using spectra-weighted mass energy-absorption coefficients, showing no considerable sign of quenching between these energies. Correction factors obtained by Monte Carlo simulations confirm that the approximations made by LCT corrections are valid. Thus, PSDs could be useful for real-time dosimetry in radiology applications. (c) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4738964]
引用
收藏
页码:5308 / 5316
页数:9
相关论文
共 50 条
  • [1] Advances in plastic scintillation detectors dosimetry
    Beaulieu, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S182 - S182
  • [2] EXTENDING ENERGY RANGE OF SCINTILLATION DETECTORS IN GAMMA-RAY DOSIMETRY
    VERSHINI.SP
    BERLOVSK.AY
    TSIRLIN, YA
    [J]. SOVIET ATOMIC ENERGY, 1968, 24 (03): : 318 - &
  • [3] Energy dependent response of plastic scintillation detectors to photon radiation of low to medium energy
    Ebenau, Melanie
    Radeck, Desiree
    Bambynek, Markus
    Sommer, Holger
    Fluehs, Dirk
    Spaan, Bernhard
    Eichmann, Marion
    [J]. MEDICAL PHYSICS, 2016, 43 (08) : 4598 - 4606
  • [4] A systematic characterization of the low-energy photon response of plastic scintillation detectors
    Boivin, Jonathan
    Beddar, Sam
    Bonde, Chris
    Schmidt, Daniel
    Culberson, Wesley
    Guillemette, Maxime
    Beaulieu, Luc
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (15): : 5569 - 5586
  • [5] Characteristics of a plastic scintillation detector in photon beam dosimetry
    Das, Indra
    Sohn, Jooyoung
    Lim, Sara
    Sengupta, Bishwambhar
    Feijoo, Marcos
    Yadav, Poonam
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (01):
  • [6] A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy
    Guillot, Mathieu
    Beaulieu, Luc
    Archambault, Louis
    Beddar, Sam
    Gingras, Luc
    [J]. MEDICAL PHYSICS, 2011, 38 (12) : 6763 - 6774
  • [7] Directional Dependence of the Response of Plastic Scintillation Detectors in Photon Beams
    Wang, L.
    Klein, D.
    Beddar, S.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [8] Dosimetry in clinical static magnetic fields using plastic scintillation detectors
    Stefanowicz, S.
    Latzel, H.
    Lindvold, L. R.
    Andersen, C. E.
    Jaekel, O.
    Greilich, S.
    [J]. RADIATION MEASUREMENTS, 2013, 56 : 357 - 360
  • [9] Monte Carlo study of the energy and angular dependence of the response of plastic scintillation detectors in photon beams
    Wang, Lille L. W.
    Klein, David
    Beddar, A. Sam
    [J]. MEDICAL PHYSICS, 2010, 37 (10) : 5279 - 5286
  • [10] RADIATION DOSIMETRY WITH SCINTILLATION DETECTORS
    BELCHER, EH
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1953, 26 (309): : 455 - 464