A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy

被引:58
|
作者
Guillot, Mathieu [1 ,3 ]
Beaulieu, Luc [1 ,3 ]
Archambault, Louis [1 ,3 ]
Beddar, Sam [2 ]
Gingras, Luc [1 ,3 ]
机构
[1] Univ Laval, Dept Phys Genie Phys & Opt, Quebec City, PQ G1K 7P4, Canada
[2] Univ Texas MD Anderson Canc Ctr, Unit 94, Dept Radiat Phys, Houston, TX 77030 USA
[3] Ctr Hosp Univ Quebec, Dept Radiooncol, Hotel Dieu Quebec, Quebec City, PQ G1R 2J6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
plastic scintillation detectors; detector array; IMRT; water-equivalence; angular dependence; IMRT QUALITY-ASSURANCE; FIBER DOSIMETER; PERFORMANCE; DISCRIMINATION; CALIBRATION; DOSIMAP; QA;
D O I
10.1118/1.3664007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The objective of this work is to present a new 2D plastic scintillation detectors array (2D-PSDA) designed for the dosimetry of megavoltage (MV) energy photon beams in radiation therapy and to characterize its basic performance. Methods: We developed a 2D detector array consisting of 781 plastic scintillation detectors (PSDs) inserted into a plane of a water-equivalent phantom. The PSDs were distributed on a 26 x 26 cm(2) grid, with an interdetector spacing of 10 mm, except for two perpendicular lines centered on the detection plane, where the spacing was 5 mm. Each PSD was made of a 1 mm diameter by 3 mm long cylindrical polystyrene scintillating fiber coupled to a clear nonscintillating plastic optical fiber. All of the light signals emitted by the PSDs were read simultaneously with an optical system at a rate of one measurement per second. We characterized the performance of the optical system, the angular dependency of the device, and the perturbation of dose distributions caused by the hundreds of PSDs inserted into the phantom. We also evaluated the capacity of the system to monitor complex multileaf collimator (MLC) sequences such as those encountered in step-and-shoot intensity modulated radiation therapy (IMRT) plans. We compared our results with calculations performed by a treatment planning system and with measurements taken with a 2D ionization chamber array and with a radiochromic film. Results: The detector array that we developed allowed us to measure doses with an average precision of better than 1% for cumulated doses equal to or greater than 6.3 cGy. Our results showed that the dose distributions produced by the 6-MV photon beam are not perturbed (within +/- 1.1%) by the presence of the hundreds of PSDs located into the phantom. The results also showed that the variations in the beam incidences have little effect on the dose response of the device. For all incidences tested, the passing rates of the gamma tests between the 2D-PSDA and the treatment planning system were higher than 97.5% when the standard clinical tolerances of 3% or 3 mm were used. Excellent agreement was obtained between the doses measured and calculated when we used the 2D-PSDA for monitoring a MLC sequence from a step-and-shoot IMRT plan. Conclusions: We demonstrated the feasibility of using a large number of PSDs in a new 2D-PSDA for the dosimetry of MV energy photon beams in radiation therapy. The excellent precision, accuracy, and low angular dependence of the device indicate that such a prototype could potentially be used as a high-accuracy quality assurance tool for IMRT and arc therapy patient plan verification. The homogeneity and water-equivalence of the prototype we built suggest that this technology could be extended to multiple detection planes by arranging the fibers into more complex orientations, opening the possibility for 3D dosimetry with PSDs. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3664007]
引用
收藏
页码:6763 / 6774
页数:12
相关论文
共 11 条
  • [1] WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .2. PROPERTIES AND MEASUREMENTS
    BEDDAR, AS
    MACKIE, TR
    ATTIX, FH
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10): : 1901 - 1913
  • [2] CHARACTERIZATION OF A NEW WATER-EQUIVALENT 2D DETECTOR ARRAY FOR THE DOSIMETRY OF IMRT PLANS
    Guillot, M.
    Gingras, L.
    Archambault, L.
    Beddar, S.
    Beaulieu, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S173 - S173
  • [3] Water equivalent plastic scintillation detectors in radiation therapy
    Beddar, A. S.
    [J]. RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) : 1 - 6
  • [4] WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .1. PHYSICAL CHARACTERISTICS AND THEORETICAL CONSIDERATIONS
    BEDDAR, AS
    MACKIE, TR
    ATTIX, FH
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10): : 1883 - 1900
  • [5] Toward a 2D Water-Equivalent Dosimetry Panel Using KCl:Eu2+
    Mazur, T.
    Xiao, Z.
    Driewer, J.
    Wang, Y.
    Li, H.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3650 - 3650
  • [6] Virtual two dimensional (2D) step wedge for film dosimetry calibration for megavoltage photon beams
    Meng, J
    [J]. EUROPEAN JOURNAL OF CANCER, 1999, 35 : S97 - S97
  • [7] Performance assessment of a 2D array of plastic scintillation detectors for IMRT quality assurance
    Guillot, Mathieu
    Gingras, Luc
    Archambault, Louis
    Beddar, Sam
    Beaulieu, Luc
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (13): : 4439 - 4454
  • [8] Liquid scintillator for 2D dosimetry for high-energy photon beams
    Poenisch, Falk
    Archambault, Louis
    Briere, Tina Marie
    Sahoo, Narayan
    Mohan, Radhe
    Beddar, Sam
    Gillin, Michael T.
    [J]. MEDICAL PHYSICS, 2009, 36 (05) : 1478 - 1485
  • [9] 2D monolithic silicon-diode array detectors in megavoltage photon beams: does the fabrication technology matter? A medical physicist’s perspective
    N. Stansook
    G. Biasi
    K. Utitsarn
    M. Petasecca
    P. Metcalfe
    M. Carolan
    M. L. F. Lerch
    V. L. Perevertaylo
    T. Kron
    A. B. Rosenfeld
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2019, 42 : 443 - 451
  • [10] 2D monolithic silicon-diode array detectors in megavoltage photon beams: does the fabrication technology matter? A medical physicist's perspective
    Stansook, N.
    Biasi, G.
    Utitsarn, K.
    Petasecca, M.
    Metcalfe, P.
    Carolan, M.
    Lerch, M. L. F.
    Perevertaylo, V. L.
    Kron, T.
    Rosenfeld, A. B.
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (02) : 443 - 451