Dosimetry in clinical static magnetic fields using plastic scintillation detectors

被引:33
|
作者
Stefanowicz, S. [1 ]
Latzel, H. [1 ,3 ]
Lindvold, L. R. [2 ]
Andersen, C. E. [2 ]
Jaekel, O. [1 ,3 ,4 ]
Greilich, S. [1 ]
机构
[1] German Canc Res Ctr, Div Med Phys Radiat Oncol, D-69120 Heidelberg, Germany
[2] Tech Univ Denmark DTU, Ctr Nucl Technol, DK-4000 Roskilde, Denmark
[3] Heidelberg Ion Beam Therapy Ctr HIT, D-69120 Heidelberg, Germany
[4] Univ Heidelberg Hosp, Dept Radiat Oncol, D-69120 Heidelberg, Germany
关键词
Scintillation dosimetry; Plastic scintillation detector (PSD); Scintillation light; Image-guided radiotherapy; MRI accelerator; MRI; ACCELERATOR; DEPENDENCE;
D O I
10.1016/j.radmeas.2013.03.012
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
To further improve the accuracy of dose delivery to the patient, several projects are pursuing the integration of linear accelerators with magnetic resonance imaging systems. Generally, this is conceived as the next generation of image-guided radiotherapy. For technical and physical reason it is, however, not clear yet how dosimetry will be conducted as standard methods and might not be easily transferred to systems with clinical magnetic fields. For dosimetry in MRI accelerators, we have tested plastic scintillation detectors (PSD) coupled to optical fibers. They are suitable for real-time and in-vivo dosimetry in radiation treatments and diagnostics and could be, being all-optical, promising candidates for this application. To study the basic feasibility of using PSDs with organic scintillators in magnetic fields, we measured the response of these dosimeters in presence of magnetic fields up to 1 T. In conclusion, we found some deviations up to 7% of the supposed signal. Although the scintillators are of much denser material, we measured the same behavior in signal as in (Meijsing et al., 2009) for a Farmer ionization chamber or as in (Raaijmakers et al., 2007) for films described which indicates radiation field effect rather than changes in the detected response itself. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:357 / 360
页数:4
相关论文
共 50 条
  • [1] Advances in plastic scintillation detectors dosimetry
    Beaulieu, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S182 - S182
  • [2] Monte Carlo modeling of the influence of strong magnetic fields on the stem-effect in plastic scintillation detectors used in radiotherapy dosimetry
    Simiele, E.
    Viscariello, N.
    DeWerd, L.
    [J]. MEDICAL PHYSICS, 2021, 48 (03) : 1381 - 1394
  • [3] TrueBeam Small Field Dosimetry Using Commercial Plastic Scintillation and Other Stereotactic Detectors
    Pino, R.
    Therriault-Proulx, F.
    Wang, X.
    Yang, J.
    Beddar, S.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 323 - 323
  • [4] A novel tool for in vivo dosimetry in diagnostic and interventional radiology using plastic scintillation detectors
    Boivin, J.
    Beddar, S.
    Guillemette, M.
    Beaulieu, L.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 680 - 684
  • [5] TOWARD A REAL-TIME IN VIVO DOSIMETRY SYSTEM USING PLASTIC SCINTILLATION DETECTORS
    Archambault, Louis
    Briere, Tina M.
    Poenisch, Falk
    Beaulieu, Luc
    Kuban, Deborah A.
    Lee, Andrew
    Beddar, Sam
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (01): : 280 - 287
  • [6] Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range
    Lessard, Francois
    Archambault, Louis
    Plamondon, Mathieu
    Despres, Philippe
    Therriault-Proulx, Francois
    Beddar, Sam
    Beaulieu, Luc
    [J]. MEDICAL PHYSICS, 2012, 39 (09) : 5308 - 5316
  • [7] RADIATION DOSIMETRY WITH SCINTILLATION DETECTORS
    BELCHER, EH
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1953, 26 (309): : 455 - 464
  • [8] Results From a 5 Patient in Vivo Rectal Wall Dosimetry Study Using Plastic Scintillation Detectors
    Wootton, L.
    Kudchadker, R.
    Lee, A.
    Beddar, S.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 96 - 97
  • [9] Plastic Scintillation Detectors: Present Status and Their Application for Quality Assurance and in Vivo Dosimetry
    Beddar, S.
    Beaulieu, L.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [10] Real-time in vivo rectal wall dosimetry using plastic scintillation detectors for patients with prostate cancer
    Wootton, Landon
    Kudchadker, Rajat
    Lee, Andrew
    Beddar, Sam
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (03): : 647 - 660