Comparison of Internal Anterior Chamber Diameter Imaging Modalities: 35-MHz Ultrasound Biomicroscopy, Visante Optical Coherence Tomography, and Pentacam

被引:15
|
作者
Kim, Sang-Kyoon [1 ]
Kim, Hyo-Myung [1 ]
Song, Jong-Suk [1 ]
机构
[1] Korea Univ, Coll Med, Guro Hosp, Dept Ophthalmol, Seoul 152703, South Korea
关键词
PHAKIC INTRAOCULAR LENSES; ROTATING SCHEIMPFLUG CAMERA; HIGH-FREQUENCY ULTRASOUND; CORNEAL THICKNESS; SEGMENT; MYOPIA; DIOPTERS; DEPTH; EYES;
D O I
10.3928/1081597X-20100121-07
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the internal diameter of the anterior chamber among three different imaging modalities: 35-MHz ultrasound biomicroscopy (UBM), Visante optical coherence tomography (OCT), and Pentacam, and to compare the internal diameters with white-to-white (WTW) distance measured by Orbscan. METHODS: The internal horizontal anterior chamber diameter was measured in 20 normal eyes using 35-MHz UBM (Optikon), Visante OCT (Carl Zeiss Meditec), and Pentacam (Oculus Inc). The mean horizontal anterior chamber diameters were compared, and the correlations between each pair of two different methods were evaluated. Horizontal WTW distance was measured by Orbscan Ilz (Bausch & Lomb-Orbtek Inc) and then correlated with the measurements of internal anterior chamber diameter. RESULTS: The mean horizontal anterior chamber diameter was 10.99 +/- 0.47 mm with UBM, 11.70 +/- 0.47 mm with OCT, and 11.86 +/- 0.45 mm with Pentacam. Ultrasound biomicroscopy measurements were significantly different than those of OCT and Pentacam (P<.001 for both). However, no significant difference was found between OCT and Pentacam (P=.19). Regarding the correlations between each pair of two different methods, UBM and OCT showed significant correlation (r=0.848, P<.001), but there was no significant correlation between OCT and Pentacam (r=0.403, P=.078), even though the mean values were similar. In the Bland-Altman plots, the range of agreement was 0.51 mm between OCT and UBM, and 0.99 mm between Pentacam and OCT. CONCLUSIONS: Although the internal anterior chamber diameters measured by 35-MHz UBM were significantly smaller than those measured by Visante OCT and Pentacam, the measurements of UBM and Visante OCT showed significant correlation and good agreement with each other. Pentacam showed poor correlation with other measurements. [J Refract Surg. 2010;26:120-126.] doi:10.3928/1081597X-20100121-07
引用
收藏
页码:120 / 126
页数:7
相关论文
共 50 条
  • [21] Comparison of Gonioscopy with Cirrus and Visante Optical Coherence Tomography (OCT) for Anterior Chamber Angle Assessment in Glaucoma Patients
    Hu, Cindy
    Zangalli, Camila
    Mantravadi, Anand
    Ali, Mohsin
    Faria, Bruno
    Richman, Jesse
    Wizov, Sheryl
    Razeghinejad, Reza
    Moster, Marlene
    Katz, L. Jay
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [22] Comparison of anterior chamber depth measurements by 3-dimensional optical coherence tomography, partial coherence interferometry biometry, Scheimpflug rotating camera imaging, and ultrasound biomicroscopy
    Nakakura, Shunsuke
    Mori, Etsuko
    Nagatomi, Nozomi
    Tabuchi, Hitoshi
    Kiuchi, Yoshiaki
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (07): : 1207 - 1213
  • [23] Comparison of central corneal thickness measurements by visante anterior segment optical coherence tomography with ultrasound pachymetry
    Zhao, Paul S.
    Wong, Tien Yin
    Wong, Wan-Ling
    Saw, Seang-Mei
    Aung, Tin
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (06) : 1047 - 1049
  • [24] Optical Coherence Tomography and Ultrasound Biomicroscopy Imaging of Opaque Corneas
    Zhou, Shi-you
    Wang, Chun-xiao
    Cai, Xiao-yu
    Huang, David
    Liu, Yi-zhi
    CORNEA, 2013, 32 (04) : E25 - E30
  • [25] Prospective comparison of ultrasound biomicroscopy and anterior segment optical coherence tomography for evaluation of anterior chamber dimensions in European eyes with primary angle closure
    Mansouri, K.
    Sommerhalder, J.
    Shaarawy, T.
    EYE, 2010, 24 (02) : 233 - 239
  • [26] Imaging the Canaliculops With Ultrasound Biomicroscopy and Anterior Segment Ocular Coherence Tomography
    Singh, Swati
    Ali, Mohammad Javed
    Peguda, Hari Kumar
    Naik, Milind N.
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2017, 33 (06): : E143 - E144
  • [27] Prospective comparison of ultrasound biomicroscopy and anterior segment optical coherence tomography for evaluation of anterior chamber dimensions in European eyes with primary angle closure
    K Mansouri
    J Sommerhalder
    T Shaarawy
    Eye, 2010, 24 : 233 - 239
  • [28] Anterior chamber angle measurement with anterior segment optical coherence tomography: A comparison between slit lamp OCT and Visante OCT
    Leung, Christopher Kai-Shun
    Li, Haitao
    Weinreb, Robert Neal
    Liu, Jing
    Cheung, Carol Yim Lui
    Lai, Ricky Yiu Kwong
    Pang, Chi Pui
    Lam, Dennis Shun Chiu
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (08) : 3469 - 3474
  • [29] Comparison of a new anterior segment optical coherence tomography and Oculus Pentacam for measurement of anterior chamber depth and corneal thickness
    Li, Xuepei
    Zhou, Yijing
    Young, Charlotte Aimee
    Chen, Aiming
    Jin, Guangming
    Zheng, Danying
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (14)
  • [30] Comparison of Anterior Segment Time Domain Optical Coherence Tomography and High Frequency Ultrasound Biomicroscopy for Anterior Segment
    Cardascia, N.
    Guerriero, S.
    Ferreri, P.
    Furino, C.
    Boscia, F.
    Vetrugno, M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)