Comparison of Internal Anterior Chamber Diameter Imaging Modalities: 35-MHz Ultrasound Biomicroscopy, Visante Optical Coherence Tomography, and Pentacam

被引:15
|
作者
Kim, Sang-Kyoon [1 ]
Kim, Hyo-Myung [1 ]
Song, Jong-Suk [1 ]
机构
[1] Korea Univ, Coll Med, Guro Hosp, Dept Ophthalmol, Seoul 152703, South Korea
关键词
PHAKIC INTRAOCULAR LENSES; ROTATING SCHEIMPFLUG CAMERA; HIGH-FREQUENCY ULTRASOUND; CORNEAL THICKNESS; SEGMENT; MYOPIA; DIOPTERS; DEPTH; EYES;
D O I
10.3928/1081597X-20100121-07
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the internal diameter of the anterior chamber among three different imaging modalities: 35-MHz ultrasound biomicroscopy (UBM), Visante optical coherence tomography (OCT), and Pentacam, and to compare the internal diameters with white-to-white (WTW) distance measured by Orbscan. METHODS: The internal horizontal anterior chamber diameter was measured in 20 normal eyes using 35-MHz UBM (Optikon), Visante OCT (Carl Zeiss Meditec), and Pentacam (Oculus Inc). The mean horizontal anterior chamber diameters were compared, and the correlations between each pair of two different methods were evaluated. Horizontal WTW distance was measured by Orbscan Ilz (Bausch & Lomb-Orbtek Inc) and then correlated with the measurements of internal anterior chamber diameter. RESULTS: The mean horizontal anterior chamber diameter was 10.99 +/- 0.47 mm with UBM, 11.70 +/- 0.47 mm with OCT, and 11.86 +/- 0.45 mm with Pentacam. Ultrasound biomicroscopy measurements were significantly different than those of OCT and Pentacam (P<.001 for both). However, no significant difference was found between OCT and Pentacam (P=.19). Regarding the correlations between each pair of two different methods, UBM and OCT showed significant correlation (r=0.848, P<.001), but there was no significant correlation between OCT and Pentacam (r=0.403, P=.078), even though the mean values were similar. In the Bland-Altman plots, the range of agreement was 0.51 mm between OCT and UBM, and 0.99 mm between Pentacam and OCT. CONCLUSIONS: Although the internal anterior chamber diameters measured by 35-MHz UBM were significantly smaller than those measured by Visante OCT and Pentacam, the measurements of UBM and Visante OCT showed significant correlation and good agreement with each other. Pentacam showed poor correlation with other measurements. [J Refract Surg. 2010;26:120-126.] doi:10.3928/1081597X-20100121-07
引用
收藏
页码:120 / 126
页数:7
相关论文
共 50 条
  • [31] Anterior chamber angle imaging with optical coherence tomography
    Leung, C. K-S
    Weinreb, R. N.
    EYE, 2011, 25 (03) : 261 - 267
  • [32] Anterior chamber angle imaging with optical coherence tomography
    C K-S Leung
    R N Weinreb
    Eye, 2011, 25 : 261 - 267
  • [33] Imaging of the anterior eye chamber with optical coherence tomography
    Wirbelauer, C
    Gochmann, R
    Pham, DT
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2005, 222 (11) : 856 - 862
  • [34] Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy in localizing horizontal rectus muscle insertions
    Duan, Rui
    Yang, Jiwen
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2024, 34 (03) : 656 - 665
  • [35] Comparison of immersion ultrasonography, ultrasound biomicroscopy and anterior segment optical coherence tomography in the evaluation of traumatic phacoceles
    Vodapalli, Harikrishna
    Murthy, Somasheila I.
    Jalali, Subhadra
    Ali, Mohammad Javed
    Rani, Padmaja Kumari
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2012, 60 (01) : 63 - 65
  • [36] Ciliary Sulcus Diameter and Two Anterior Chamber Parameters Measured by Optical Coherence Tomography and VHF Ultrasound
    Pinero, David P.
    Plaza Puche, Ana Belen
    Alio, Jorge L.
    JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (11) : 1017 - 1025
  • [37] Measurement of the internal diameter and depth of the anterior chamber: IOLMaster versus anterior chamber optical coherence tomographer
    Baikoff, G
    Jodai, HJ
    Bourgeon, G
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09): : 1722 - 1728
  • [38] Comparing Gonioscopy With Visante and Cirrus Optical Coherence Tomography for Anterior Chamber Angle Assessment in Glaucoma Patients
    Hu, Cindy X.
    Mantravadi, Anand
    Zangalli, Camila
    Ali, Mohsin
    Faria, Bruno M.
    Richman, Jesse
    Wizov, Sheryl S.
    Razeghinejad, M. Reza
    Moster, Marlene R.
    Katz, L. Jay
    JOURNAL OF GLAUCOMA, 2016, 25 (02) : 177 - 183
  • [39] Comparison of Artemis 2 Ultrasound and Visante Optical Coherence Tomography Corneal Thickness Profiles
    Ursea, Roxana
    Feng, Matthew
    Urs, Raksha
    RoyChoudhury, Arindam
    Silverman, Ronald H.
    JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (01) : 36 - +
  • [40] Structural and Doppler imaging of Xenopus laevis embryos in vivo: A comparison of ultrasound biomicroscopy and optical coherence tomography
    Needles, A
    Yang, VXD
    Wilson, BC
    Vitkin, IA
    Foster, FS
    2003 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2003, : 758 - 761