Comparison of Internal Anterior Chamber Diameter Imaging Modalities: 35-MHz Ultrasound Biomicroscopy, Visante Optical Coherence Tomography, and Pentacam

被引:15
|
作者
Kim, Sang-Kyoon [1 ]
Kim, Hyo-Myung [1 ]
Song, Jong-Suk [1 ]
机构
[1] Korea Univ, Coll Med, Guro Hosp, Dept Ophthalmol, Seoul 152703, South Korea
关键词
PHAKIC INTRAOCULAR LENSES; ROTATING SCHEIMPFLUG CAMERA; HIGH-FREQUENCY ULTRASOUND; CORNEAL THICKNESS; SEGMENT; MYOPIA; DIOPTERS; DEPTH; EYES;
D O I
10.3928/1081597X-20100121-07
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the internal diameter of the anterior chamber among three different imaging modalities: 35-MHz ultrasound biomicroscopy (UBM), Visante optical coherence tomography (OCT), and Pentacam, and to compare the internal diameters with white-to-white (WTW) distance measured by Orbscan. METHODS: The internal horizontal anterior chamber diameter was measured in 20 normal eyes using 35-MHz UBM (Optikon), Visante OCT (Carl Zeiss Meditec), and Pentacam (Oculus Inc). The mean horizontal anterior chamber diameters were compared, and the correlations between each pair of two different methods were evaluated. Horizontal WTW distance was measured by Orbscan Ilz (Bausch & Lomb-Orbtek Inc) and then correlated with the measurements of internal anterior chamber diameter. RESULTS: The mean horizontal anterior chamber diameter was 10.99 +/- 0.47 mm with UBM, 11.70 +/- 0.47 mm with OCT, and 11.86 +/- 0.45 mm with Pentacam. Ultrasound biomicroscopy measurements were significantly different than those of OCT and Pentacam (P<.001 for both). However, no significant difference was found between OCT and Pentacam (P=.19). Regarding the correlations between each pair of two different methods, UBM and OCT showed significant correlation (r=0.848, P<.001), but there was no significant correlation between OCT and Pentacam (r=0.403, P=.078), even though the mean values were similar. In the Bland-Altman plots, the range of agreement was 0.51 mm between OCT and UBM, and 0.99 mm between Pentacam and OCT. CONCLUSIONS: Although the internal anterior chamber diameters measured by 35-MHz UBM were significantly smaller than those measured by Visante OCT and Pentacam, the measurements of UBM and Visante OCT showed significant correlation and good agreement with each other. Pentacam showed poor correlation with other measurements. [J Refract Surg. 2010;26:120-126.] doi:10.3928/1081597X-20100121-07
引用
收藏
页码:120 / 126
页数:7
相关论文
共 50 条
  • [41] Comparison of Ocular Morphological Parameters Related to Lens Position by Anterior Segment Optical Coherence Tomography and Ultrasound Biomicroscopy
    Yu, Zhiying
    Wang, Fenglei
    Dong, Fang
    Li, Na
    Wang, Dabo
    Wang, Ling
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2022, 2022 : 7599631
  • [42] Correlation of anterior segment optical coherence tomography and ultrasound biomicroscopy in congenital corneal opacity
    Yangzes, Sonam
    Kaushik, Sushmita
    Malhotra, Chintan
    Thakur, Anchal
    Gupta, Amit
    Jain, Arun Kumar
    Jinagal, Jitender
    Pandav, Surinder Singh
    JOURNAL OF AAPOS, 2024, 28 (02):
  • [43] Comparison of ultrasound biomicroscopy and spectraldomain anterior segment optical coherence tomography in evaluation of anterior segment after laser peripheral iridotomy
    Xiao-Yun Ma
    Dan Zhu
    Jun Zou
    Wen-Jie Zhang
    Yi-Lin Cao
    International Journal of Ophthalmology, 2016, 9 (03) : 417 - 423
  • [44] Comparison of optical coherence tomography and ultrasound biomicroscopy in identifying anatomically narrow angles
    Goldsmith, JA
    Radhakrishnan, S
    Westphal, V
    Huang, D
    Dueker, DK
    Rollins, AM
    Izatt, JA
    Smith, SD
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U55 - U55
  • [45] Anterior segment tumor imaging: Advantages of ultrasound (10, 20 and 50 MHz) and optical coherence tomography
    Siahmed, K
    Berges, O
    Desjardins, L
    Lumbroso, L
    Brasseur, G
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2004, 27 (02): : 169 - 173
  • [46] Comparing Gonioscopy With Visante and Cirrus Optical Coherence Tomography for Anterior Chamber Angle Assessment in Glaucoma Patients In Reply
    Zheng, Cindy X.
    Mantravadi, Anand V.
    Zangalli, Camila
    Katz, L. Jay
    JOURNAL OF GLAUCOMA, 2017, 26 (03) : E125 - E126
  • [47] Comparison of anterior section parameters using anterior segment optical coherence tomography and ultrasound biomicroscopy in myopic patients after ICL implantation
    Zhang, Jing
    Luo, Hui-Hui
    Zhuang, Jing
    Yu, Ke-Ming
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (01) : 58 - 62
  • [48] Comparison of anterior section parameters using anterior segment optical coherence tomography and ultrasound biomicroscopy in myopic patients after ICL implantation
    Jing Zhang
    Hui-Hui Luo
    Jing Zhuang
    Ke-Ming Yu
    International Journal of Ophthalmology, 2016, (01) : 58 - 62
  • [49] Imaging of trabeculectomy blebs with Visante anterior segment optical coherence tomography after digital ocular compression
    Park, Hae-Young Lopilly
    Ahn, Myung Douk
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2012, 56 (01) : 38 - 45
  • [50] Conjunctival melanocytic naevus: Diagnostic value of anterior segment optical coherence tomography and ultrasound biomicroscopy
    Vizvari, Eszter
    Skribek, Akos
    Polgar, Nora
    Voros, Andras
    Sziklai, Pal
    Toth-Molnar, Edit
    PLOS ONE, 2018, 13 (02):