Ciliary Sulcus Diameter and Two Anterior Chamber Parameters Measured by Optical Coherence Tomography and VHF Ultrasound

被引:17
|
作者
Pinero, David P. [1 ,2 ]
Plaza Puche, Ana Belen [1 ]
Alio, Jorge L. [1 ,3 ]
机构
[1] Vissum Inst Oftalmol Alicante, Alicante, Spain
[2] Univ Alicante, Dept Opt Farmacol & Anat, Alicante, Spain
[3] Univ Miguel Hernandez, Div Ophthalmol, Alicante, Spain
关键词
PHAKIC INTRAOCULAR-LENS; IMPLANTABLE CONTACT-LENS; 2-YEAR FOLLOW-UP; CORNEAL DIAMETER; REFRACTIVE LENS; HIGH MYOPIA; ANGLE; SEGMENT; BIOMICROSCOPY; DIOPTERS;
D O I
10.3928/1081597X-20091016-08
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the relationship between two anterior chamber anatomical parameters, angle-to-angle and iris pigment end-to-iris pigment end distances, and sulcus-to-sulcus diameter. METHODS: Twenty eyes without active ocular pathologies or previous ocular surgeries from 20 patients ranging in age from 23 to 51 years were included in this study. Mean spherical equivalent refraction ranged from +5.50 to -7.00 diopters. Angle-to-angle and iris pigment end-to-iris pigment end distances were measured in all cases three times consecutively using two technologies: optical coherence tomography (OCT) and very high-frequency ultrasonography. Sulcus-to-sulcus diameter was additionally obtained by ultrasonography. Correlation, linear regression, intrasession, and interchangeability analysis between parameters was performed, RESULTS: Mean sulcus-to-sulcus diameter was 11.92 +/- 0.80 mm. Mean angle-to-angle distance was 12.14 +/- 0.52 mm for ultrasonography and 12.23 +/- 0.59 mm for OCT. Mean iris pigment end-to-iris pigment end distance was 12.18 +/- 0.51, mm for ultrasonography and 12.29 +/- 0.61 mm for OCT. No statistically significant differences were found among these anatomical parameters (unpaired Student t test, all P>.10). Statistically significant correlations were found between sulcus-to-sulcus diameter and angle-to-angle distance and between sulcus-to-sulcus diameter and iris pigment end-to-iris pigment end distance for both imaging techniques. For ultrasonography, range of agreement was 0.90 mm between sulcus-to-sulcus diameter and angle-to-angle distance and 0.74 mm between sulcus-to-sulcus diameter and iris pigment end-to-iris pigment end distance, These ranges increased to 1.22 mm and 1.14 mm, respectively, for OCT measurements. CONCLUSIONS: Angle-to-angle and iris pigment end-to-iris pigment end distances are correlated with sulcus-to-sulcus diameter, but they cannot be used as equivalent parameters. [J Refract Surg. 2009;25:1017-1025.] doi:10.3928/1081597X-20091016-08
引用
收藏
页码:1017 / 1025
页数:9
相关论文
共 50 条
  • [1] Relationship between ciliary sulcus diameter and anterior chamber diameter and corneal diameter
    Kawamorita, Takushi
    Uozato, Hiroshi
    Kamiya, Kazutaka
    Shimizu, Kimiya
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (04): : 617 - 624
  • [2] Correlation of Anterior Chamber Angle and Ciliary Sulcus Diameters With White-to-White Corneal Diameter in High Myopes Using Artemis VHF Digital Ultrasound
    Reinstein, Dan Z.
    Archer, Timothy J.
    Silverman, Ronald H.
    Rondeau, Mark J.
    Coleman, D. Jackson
    JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (02) : 185 - 194
  • [3] Effect of Hemodialysis on Anterior Chamber Angle Measured by Anterior Segment Optical Coherence Tomography
    Shin, Yong Un
    Kim, Ji Hong
    Cho, Heeyoon
    Kim, Dae Sung
    Yi, Joo-Hark
    Han, Sang-Woong
    Seong, Mincheol
    JOURNAL OF OPHTHALMOLOGY, 2019, 2019
  • [4] Direct Measurement of the Ciliary Sulcus Diameter Using Optical Coherence Tomography-Inter-Rater Variability
    Eppig, Timo
    Seer, Manuel
    Martinez-Abad, Antonio
    Galvis, Virgilio
    Schuetz, Saskia
    Tello, Alejandro
    Rombach, Michiel C.
    Alio, Jorge L.
    SENSORS, 2024, 24 (21)
  • [5] Direct measurement of the ciliary sulcus diameter using optical coherence tomography: Inter-rater variability
    Eppig, Timo
    Seer, Manuel
    Abad, Antonio Martinez
    Galvis, Virgilio
    Tello, Alejandro
    Schutz, Saskia
    Rombach, Michiel
    Alio, Jorge L.
    ACTA OPHTHALMOLOGICA, 2024, 102
  • [6] Evaluation of anterior chamber parameters with spectral-domain optical coherence tomography
    Isabel Pinilla Lozano
    Carmen López de la Fuente
    Francisco Segura
    Elvira Orduna Hospital
    Ana Sánchez-Cano
    Japanese Journal of Ophthalmology, 2018, 62 : 209 - 215
  • [7] Evaluation of anterior chamber parameters with spectral-domain optical coherence tomography
    Pinilla Lozano, Isabel
    Lopez de la Fuente, Carmen
    Segura, Francisco
    Orduna Hospital, Elvira
    Sanchez-Cano, Ana
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2018, 62 (02) : 209 - 215
  • [8] Determination and Validation of Thresholds of Anterior Chamber Parameters by Dedicated Anterior Segment Optical Coherence Tomography
    Melese, Ephrem K.
    Chan, Jeffrey D.
    Blieden, Lauren S.
    Chuang, Alice Z.
    Baker, Laura A.
    Bell, Nicholas P.
    Feldman, Robert M.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 169 : 208 - 217
  • [9] Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles
    Radhakrishnan, S
    Goldsmith, J
    Huang, D
    Westphal, V
    Dueker, DK
    Rollins, AM
    Izatt, JA
    Smith, SD
    ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (08) : 1053 - 1059
  • [10] Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy
    Zi-Yan Yu
    Ting Huang
    Lu Lu
    Bo Qu
    World Journal of Clinical Cases, 2020, (15) : 3249 - 3258