Evaluation of the i-STAT Alinity v in a veterinary clinical setting

被引:3
|
作者
Burke, Jasper E. [1 ]
Nguyen, Thuy Hien T. [2 ]
Davis, Tanya [2 ]
Koenig, Amie [1 ]
Lane, Selena L. [1 ]
Good, Jennifer [1 ]
Brainard, Benjamin M. [1 ]
机构
[1] Univ Georgia, Coll Vet Med, Dept Small Anim Med & Surg, Athens, GA USA
[2] Zoetis Inc, Parsippany, NJ USA
关键词
blood gas; cats; dogs; electrolytes; emergency; point-of-care; BLOOD-GASES; ANALYZER; PH; ELECTROLYTES; GUIDELINES; ACCURACY;
D O I
10.1177/10406387211019710
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Many point-of-care (POC) analyzers are available for the measurement of electrolytes and acid-base status in animals. We assessed the precision of the i-STAT Alinity v, a recently introduced POC analyzer, and compared it to 2 commonly used and previously validated POC analyzers (i-STAT 1, Stat Profile pHOx Ultra). Precision was evaluated by performing multiple analyses of whole blood samples from healthy dogs, cats, and horses on multiple i-STAT Alinity v analyzers. For comparison between analyzers, whole blood samples from dogs and cats presented to the emergency room were run concurrently on all 3 POC instruments. Reported values were compared by species (dogs and cats only) using Pearson correlation, and all values from all species were analyzed together for the Bland-Altman analysis. Results suggested that the i-STAT Alinity v precision was very good, with median coefficients of variability <2.5% for all measured parameters (except the anion gap), with variable ranges of coefficients of variation. In addition, good-to-excellent correlation was observed between the i-STAT Alinity v and i-STAT 1, and between the i-STAT Alinity v and Stat Profile pHOx Ultra for all parameters in both cats and dogs, respectively. In this cohort, the i-STAT Alinity v had clinically acceptable bias compared to the currently marketed analyzers and can be used for monitoring measured analytes in cats and dogs, although serial measurements in a single animal should be performed on the same analyzer whenever possible.
引用
收藏
页码:703 / 710
页数:8
相关论文
共 50 条
  • [31] AN EVALUATION OF BLOOD-GAS AND IONIZED CALCIUM MEASUREMENT OF THE I-STAT ANALYZER
    MOCK, T
    YATSCOFF, RW
    CLINICAL CHEMISTRY, 1995, 41 (06) : S182 - S182
  • [32] Analytical performance evaluation of the i-STAT Total β-human chorionic gonadotropin immunoassay
    Sowder, Aleksandra M.
    Yarbrough, Melanie L.
    Nerenz, Robert D.
    Mitsios, John V.
    Mortensen, Rachel
    Gronowski, Ann M.
    Grenache, David G.
    CLINICA CHIMICA ACTA, 2015, 446 : 165 - 170
  • [33] QUALITY-CONTROL FOR THE I-STAT ANALYZER
    UTZ, C
    GIBSON, C
    HORTIN, GL
    CLINICAL CHEMISTRY, 1995, 41 (06) : S157 - S157
  • [34] I-STAT - INTERACTIVE STATISTICAL PROGRAM PACKAGE
    ROSENBLO.L
    CHAPMAN, K
    BEHAVIOR RESEARCH METHODS & INSTRUMENTATION, 1974, 6 (01): : 56 - 56
  • [35] Evaluation of the i-STAT analyzer for determination of ionized calcium concentrations in bovine blood
    Yilmaz, Oznur
    Karapinar, Tolga
    VETERINARY CLINICAL PATHOLOGY, 2019, 48 (01) : 31 - 35
  • [36] i-STAT biosensor system to be distributed in Europe
    不详
    BIOSENSORS & BIOELECTRONICS, 1996, 11 (09): : R2 - R2
  • [37] Evaluation of the next generation I-STAT® point-of-care prothrombin time test (I-STAT PTPLUS) against other commercially available prothrombin time tests
    Frank, P.
    Ball, S.
    Thibodeau, L.
    Perry, R.
    Ditullio, K.
    Wilson, K.
    Trivedi, A.
    Villeneuve, A.
    CLINICA CHIMICA ACTA, 2019, 493 : S645 - S645
  • [38] Analytical performance of the i-STAT cardiac troponin I assay
    Apple, FS
    Murakami, MM
    Christenson, RH
    Campbell, JL
    Miller, CJ
    Hock, KG
    Scott, MG
    CLINICA CHIMICA ACTA, 2004, 345 (1-2) : 123 - 127
  • [39] Evaluation of the CoaguChek S, CoaguChek XS and i-STAT for Point of Care INR testing
    Beyer, L. K.
    Wockenfus, A.
    McBane, R.
    Chaudhry, R.
    Karon, B.
    Santrach, P.
    CLINICAL CHEMISTRY, 2008, 54 (06) : A198 - A199
  • [40] Accuracy of the i-STAT™ bedside blood gas analyser
    Sediame, S
    Zerah-Lancner, F
    d'Ortho, MP
    Adnot, S
    Harf, A
    EUROPEAN RESPIRATORY JOURNAL, 1999, 14 (01) : 214 - 217