Analytical performance evaluation of the i-STAT Total β-human chorionic gonadotropin immunoassay

被引:14
|
作者
Sowder, Aleksandra M. [1 ]
Yarbrough, Melanie L. [2 ]
Nerenz, Robert D. [2 ]
Mitsios, John V. [2 ]
Mortensen, Rachel [3 ]
Gronowski, Ann M. [2 ,4 ]
Grenache, David G. [1 ,5 ]
机构
[1] Univ Utah, Sch Med, Dept Pathol, Salt Lake City, UT USA
[2] Washington Univ, Sch Med, Dept Pathol & Immunol, St Louis, MO USA
[3] ARUP Labs, Salt Lake City, UT 84108 USA
[4] Washington Univ, Sch Med, Dept Obstet & Gynecol, St Louis, MO 63110 USA
[5] ARUP Inst Clin & Expt Pathol, Salt Lake City, UT USA
关键词
Human chorionic gonadotropin; Quantitative; Whole blood; Point-of-care; Pregnancy test; POINT-OF-CARE; QUALITATIVE POINT; HCG DEVICES; URINE; PREGNANCY;
D O I
10.1016/j.cca.2015.04.025
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The ability to perform quantitative hCG testing in whole blood at the point-of-care is desirable. The purpose of this study was to perform an analytical validation of the Abbott i-STAT Total beta-hCG test. Methods: Whole blood, plasma, and serum samples were prepared by the addition of hCG and were used to evaluate precision, linearity, analytical sensitivity, accuracy, the high-dose hook effect, and dilution recovery. Results: Imprecision was highest with whole blood (CV = 16.0% and 6.7% at 10 and 1184 IU/l, respectively) and lowest in serum (CV = 8.1% and 4.3% at 11 and 1305 IU/l, respectively). The limits-of-quantitation were 8 and <5 IU/l for whole blood and both plasma and serum, respectively. The assay was linear between 5 and 2000 IU/l in all sample types (R-2 >= 0.998). i-STAT results agreed most closely with the Architect Total beta-hCG assay and with greater differences observed with Beckman Dxl Total beta hCG and Roche Cobas e601 hCG + beta assays (mean differences across all sample types were 9.3% and 12.3%, respectively). A high-dose hook effect was observed at concentrations >400,000 IU/l. Accuracy was achieved in samples diluted with serum but not saline. Conclusions: The i-STAT Total beta-hCG test demonstrates acceptable performance for quantifying hCG in whole blood, plasma and serum. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:165 / 170
页数:6
相关论文
共 50 条
  • [1] Hook effect in Abbott i-STAT β-human chorionic gonadotropin (β-hCG) point of care assay
    Wilgen, Urs
    Pretorius, Carel J.
    Gous, Rehna S.
    Martin, Cameron
    Hale, Vincent J.
    Ungerer, Jacobus P. J.
    CLINICAL BIOCHEMISTRY, 2014, 47 (13-14) : 1320 - 1322
  • [2] Analytical performance of the i-STAT cardiac troponin I assay
    Apple, FS
    Murakami, MM
    Christenson, RH
    Campbell, JL
    Miller, CJ
    Hock, KG
    Scott, MG
    CLINICA CHIMICA ACTA, 2004, 345 (1-2) : 123 - 127
  • [3] Differences in Total Human Chorionic Gonadotropin Immunoassay Analytical Specificity and Ability to Measure Human Chorionic Gonadotropin in Gestational Trophoblastic Disease and Germ Cell Tumors
    Harvey, Richard A.
    Mitchell, Hugh D. C.
    Stenman, Ulf-Hakan
    Blankenstein, M. A.
    Nustad, Kjell
    Stieber, Petra
    Stewart, Wilson
    Savage, Philip M.
    Seckl, Michael J.
    Braunstein, Glenn D.
    JOURNAL OF REPRODUCTIVE MEDICINE, 2010, 55 (7-8) : 285 - 295
  • [4] Analytical performance of the i-STAT cardiac troponin I assay.
    Apple, FS
    Murakami, MM
    Christenson, RH
    Campbell, JL
    Miller, CJ
    Hock, KG
    Scott, MG
    CLINICAL CHEMISTRY, 2004, 50 (06) : A9 - A9
  • [5] IMMUNOASSAY AND BIOASSAY OF HUMAN CHORIONIC GONADOTROPIN
    LADA, G
    BADAR, E
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1972, 29 : 248 - &
  • [6] Evaluation of i-STAT creatinine assay
    Gault, MH
    Seymour, ME
    Howell, WE
    NEPHRON, 2001, 88 (02): : 178 - 182
  • [8] EVALUATION OF HUMAN CHORIONIC-GONADOTROPIN ON THE ABBOTT IMX AUTOMATED IMMUNOASSAY SYSTEMS
    CHOU, PP
    TOMS, RA
    KING, B
    CHANG, A
    LONGHURST, S
    YOUNG, M
    CLINICAL CHEMISTRY, 1989, 35 (06) : 1099 - 1099
  • [9] Gradient Lateral Flow Immunoassay of Human Chorionic Gonadotropin
    Serebrennikova K.V.
    Samsonova J.V.
    Osipov A.P.
    Moscow University Chemistry Bulletin, 2017, 72 (6) : 325 - 327
  • [10] EVALUATION OF AN ENZYME-IMMUNOASSAY FOR THE DETERMINATION OF HUMAN CHORIONIC-GONADOTROPIN IN HUMAN-SERUM
    KESSLER, AC
    WEHNER, R
    KUPPERS, R
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1986, 24 (10): : 762 - 763