Evaluation of the i-STAT analyzer for determination of ionized calcium concentrations in bovine blood

被引:18
|
作者
Yilmaz, Oznur [1 ]
Karapinar, Tolga [1 ]
机构
[1] Firat Univ, Dept Internal Med, Fac Vet Med, Elazig, Turkey
关键词
calcium; cattle; cow; point-of-care; sensitivity; PORTABLE CLINICAL ANALYZER; GAS PARTIAL PRESSURES; SUBCLINICAL HYPOCALCEMIA; ELECTROLYTE CONCENTRATIONS; NEUTROPHIL FUNCTION; DAIRY; PREVALENCE; PREDICTION; PLASMA; DEVICE;
D O I
10.1111/vcp.12705
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background Information regarding the performance of the i-STAT, a point-of-care analyzer, to determine ionized calcium (iCa(2+)) concentration in bovine blood is limited. Objective The primary goal of this study was to evaluate the agreement of the i-STAT against a traditional bench-top blood gas analyzer (Radiometer ABL800 FLEX) in the measurement of iCa(2+) in the blood of cattle with various disorders. Methods In this study, 121 cattle with various diseases were used. Venous blood samples were run on the i-STAT and the Radiometer ABL800 FLEX for determination of blood iCa(2+) concentrations. Data were subjected to Passing-Bablok regression and Bland-Altman plots. The Radiometer ABL800 FLEX was the reference method and the i-STAT was the test method. The i-STAT performance was evaluated at two different cutoff values for iCa(2+) concentrations (<1.00 and <1.18 mmol/L) using the receiver operating characteristic curve. Results The Passing-Bablok regression equation that fit the iCa(2+) concentration as measured with the i-STAT (Y) and the Radiometer ABL800 FLEX (X), was Y = -0.108276 [-0.15/-0.06] + 1.103448 [1.06/1.14] x X, with a residual deviation of 0.02. The deviation from the identity line was not significant (P = 0.64). The Bland-Altman difference plot revealed no bias between the i-STAT and the Radiometer ABL 800 FLEX. The i-STAT had a sensitivity of 100% (95% CI, 87.7-100.0) and 94.8% (95% CI, 87.2-98.6) at the iCa(2+) concentration cutoff values of <1.00 and <1.18 mmol/L, respectively. Conclusions iCa(2+) concentrations in bovine blood measured with the i-STAT agreed with those of the Radiometer ABL800 FLEX. In particular, the i-STAT predicted hypocalcemia with a high sensitivity.
引用
收藏
页码:31 / 35
页数:5
相关论文
共 50 条
  • [1] AN EVALUATION OF BLOOD-GAS AND IONIZED CALCIUM MEASUREMENT OF THE I-STAT ANALYZER
    MOCK, T
    YATSCOFF, RW
    CLINICAL CHEMISTRY, 1995, 41 (06) : S182 - S182
  • [2] DETERMINATION OF IONIZED CALCIUM CONTENT OF BOVINE BLOOD BY IONIZED CALCIUM ANALYZER
    SZENCI, O
    MARZ, I
    MAGYAR ALLATORVOSOK LAPJA, 1987, 42 (02) : 121 - 123
  • [3] Evaluation of the i-STAT® Portable Clinical Analyzer for the determination of blood creatinine.
    Marver, CL
    Santrach, PJ
    Burritt, MF
    CLINICAL CHEMISTRY, 1999, 45 (06) : A33 - A33
  • [4] EVALUATION OF THE I-STAT PORTABLE CLINICAL ANALYZER FOR MEASUREMENT OF IONIZED CALCIUM AND SELECTED BLOOD CHEMISTRY VALUES IN ASIAN ELEPHANTS (ELEPHAS MAXIMUS)
    Tarbert, Danielle K.
    Behling-Kelly, Erica
    Priest, Heather
    Childs-Sanford, Sara
    JOURNAL OF ZOO AND WILDLIFE MEDICINE, 2017, 48 (02) : 319 - 327
  • [5] Evaluation of the i-STAT Portable Clinical Analyzer in dogs
    Matburger, C
    Henke, J
    Hirschberger, J
    Matburger, S
    Erhardt, W
    TIERARZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 2000, 28 (02): : 132 - 137
  • [6] Evaluation of the i-STAT portable clinical analyzer for use in a helicopter
    Burritt, MF
    Santrach, PJ
    Hankins, DG
    Herr, D
    Newton, NC
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1996, 56 : 121 - 128
  • [7] Evaluation of i-STAT portable clinical analyzer in a hemodialysis unit
    Gault, MH
    Harding, CE
    CLINICAL BIOCHEMISTRY, 1996, 29 (02) : 117 - 124
  • [8] Evaluation of the i-STAT Alinity Point-of-Care Analyzer
    Lee, Mee-Yin
    Lim, Sian-Foong
    Lam, Leslie
    POINT OF CARE, 2019, 18 (02): : 48 - 55
  • [9] I-STAT: The Instant Portable Analyzer
    Wynn, Alice
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2012, 138 : A058 - A058
  • [10] EVALUATION OF BLOOD-GAS AND PH METHODS ON THE I-STAT(TM) PORTABLE CLINICAL ANALYZER
    BOTTJEN, PL
    HAVEN, MC
    CLINICAL CHEMISTRY, 1995, 41 (06) : S196 - S196