Evaluation of the i-STAT portable clinical analyzer for use in a helicopter
被引:17
|
作者:
Burritt, MF
论文数: 0引用数: 0
h-index: 0
机构:
MAYO CLIN & MAYO FDN,DIV EMERGENCY MED SERV & INTERNAL MED,ROCHESTER,MN 55905MAYO CLIN & MAYO FDN,DIV EMERGENCY MED SERV & INTERNAL MED,ROCHESTER,MN 55905
Burritt, MF
[1
]
Santrach, PJ
论文数: 0引用数: 0
h-index: 0
机构:
MAYO CLIN & MAYO FDN,DIV EMERGENCY MED SERV & INTERNAL MED,ROCHESTER,MN 55905MAYO CLIN & MAYO FDN,DIV EMERGENCY MED SERV & INTERNAL MED,ROCHESTER,MN 55905
Santrach, PJ
[1
]
Hankins, DG
论文数: 0引用数: 0
h-index: 0
机构:
MAYO CLIN & MAYO FDN,DIV EMERGENCY MED SERV & INTERNAL MED,ROCHESTER,MN 55905MAYO CLIN & MAYO FDN,DIV EMERGENCY MED SERV & INTERNAL MED,ROCHESTER,MN 55905
Hankins, DG
[1
]
Herr, D
论文数: 0引用数: 0
h-index: 0
机构:
MAYO CLIN & MAYO FDN,DIV EMERGENCY MED SERV & INTERNAL MED,ROCHESTER,MN 55905MAYO CLIN & MAYO FDN,DIV EMERGENCY MED SERV & INTERNAL MED,ROCHESTER,MN 55905
Herr, D
[1
]
Newton, NC
论文数: 0引用数: 0
h-index: 0
机构:
MAYO CLIN & MAYO FDN,DIV EMERGENCY MED SERV & INTERNAL MED,ROCHESTER,MN 55905MAYO CLIN & MAYO FDN,DIV EMERGENCY MED SERV & INTERNAL MED,ROCHESTER,MN 55905
Newton, NC
[1
]
机构:
[1] MAYO CLIN & MAYO FDN,DIV EMERGENCY MED SERV & INTERNAL MED,ROCHESTER,MN 55905
We evaluated the performance of the i-STAT Portable Clinical Analyzer (PCA) for use in a helicopter with the analyses performed by the flight nurses. Imprecision and initial split-sample comparative studies were performed in the Hospital Laboratory and Clinical Chemistry Laboratory. Day-to day imprecision (CV) ranged from 0.5 to 6.7% in the clinical laboratories and 0.5 to 5.3% in the helicopter with urea nitrogen and glucose determinations giving the highest values. Comparison studies between the PCA and the Kodak Ektachem E700 and the Beckman Astra 8 gave acceptable results, although urea nitrogen did show a bias in the high range (mean difference 4.91 and 3.69 mmol/L respectively). It was not considered medically significant for the anticipated patient population of the PCA in our hospitals. Comparison studies of patient specimens between the PCA in the helicopter and the clinical laboratories showed no significant differences, with the exception of glucose. Lower glucose values were obtained in the laboratory due to the time lag between specimen collection in the helicopter and analysis in the laboratory.
机构:
Univ Texas, MD Anderson Canc Ctr, Dept Vet Med & Surg, Houston, TX 77030 USAUniv Texas, MD Anderson Canc Ctr, Dept Vet Med & Surg, Houston, TX 77030 USA
Tinkey, Peggy
Lembo, Thomas
论文数: 0引用数: 0
h-index: 0
机构:
Univ Texas, MD Anderson Canc Ctr, Dept Vet Med & Surg, Houston, TX 77030 USAUniv Texas, MD Anderson Canc Ctr, Dept Vet Med & Surg, Houston, TX 77030 USA
Lembo, Thomas
Craig, Suzanne
论文数: 0引用数: 0
h-index: 0
机构:
Univ Texas, MD Anderson Canc Ctr, Dept Vet Med & Surg, Houston, TX 77030 USAUniv Texas, MD Anderson Canc Ctr, Dept Vet Med & Surg, Houston, TX 77030 USA
Craig, Suzanne
West, Cheri
论文数: 0引用数: 0
h-index: 0
机构:
Univ Texas, MD Anderson Canc Ctr, Dept Vet Med & Surg, Houston, TX 77030 USAUniv Texas, MD Anderson Canc Ctr, Dept Vet Med & Surg, Houston, TX 77030 USA
West, Cheri
Van Pelt, Carolyn
论文数: 0引用数: 0
h-index: 0
机构:
Univ Texas, MD Anderson Canc Ctr, Dept Vet Med & Surg, Houston, TX 77030 USAUniv Texas, MD Anderson Canc Ctr, Dept Vet Med & Surg, Houston, TX 77030 USA