Pullout strength of tibial graft fixation in ACL-replacement with a patellar tendon graft: Interference screw versus staple fixation in human knees

被引:4
|
作者
Gerich, TG [1 ]
Cassim, A [1 ]
Lattermann, C [1 ]
Lobenhoffer, HP [1 ]
Tscherne, H [1 ]
机构
[1] Med Hsch Hannover, Unfallchirurg Klin, D-30625 Hannover, Germany
来源
UNFALLCHIRURG | 1998年 / 101卷 / 03期
关键词
anterior cruciate ligament; patellar tendon transplant; biomechanics;
D O I
10.1007/s001130050255
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The endoscopic single incision technique for ACL reconstruction with a femoral half-tunnel may lead to a graft/tunnel mismatch and subsequent protrusion of the block from the tibial tunnel. The typical tibial fixation with an interference screw is not possible in these cases. Fixation with staples in a bony groove inferior to the tunnel outlet can be used as an alternative technique. Current literature does not provide biomechanical data of bath fixation techniques in a human model. This study was performed to evaluate primary biomechanical parameters of this technique compared to a standard interference screw fixation of the block. 55 fresh-frozen human cadaver knee joints of a younger age (mean age: 44 years) were used. Grafts were harvested from the patellar tendon midportion with bone blocks of 25 mm length and 9 mm width. A 10 mm tibial tunnel was drilled from the anteromedial cortex to the center of the tibial insertion of the ACL. 3 different sizes of interference screws (7 x 30, 9 x 20 and 9 x 30 mm) were chosen as a standard control procedure (n = 40). For tibial bone-block fixation the graft was placed through the tunnel, the screw was then inserted on the cancellous or the cortical surface respectively. 15 knees were used far staple fixation. A groove was created inferior to the tunnel outlet with a chisel. The bone block was fixed in this groove with 2 barbed stainless steel staples. Tensile testing in both of the groups was carried out under axial load parallel to the tibial tunnel in a Zwick-testing-machine with a Velocity of 1 mm/sec. Dislocation of the graft and stiffness were calculated at 175 N load. Maximum load to failure using interference screws varied between 506 and 758 N. load to failure using staples was 588 N. Dislocation of the graft ranged between 3.6 and 4.7 mm for interference screw fixation and was 4.2 mm for staples. With both fixation techniques, the recorded failure loads were sufficient to withstand the graft loads which are to be expected during the rehabilitation period. Staple fixation of the bone block outside of the tunnel resulted in fixation strength comparable to interference screw fixation.
引用
收藏
页码:204 / 208
页数:5
相关论文
共 50 条
  • [21] Interference screw insertion angle has no effect on graft fixation strength for insertional Achilles tendon reconstruction
    Wu, Ziying
    Li, Hongyun
    Chen, Shiyi
    Ma, Kui
    Li, Shengkun
    Zhang, Peng
    Hua, Yinghui
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (12) : 3606 - 3610
  • [22] Interference screw insertion angle has no effect on graft fixation strength for insertional Achilles tendon reconstruction
    Ziying Wu
    Hongyun Li
    Shiyi Chen
    Kui Ma
    Shengkun Li
    Peng Zhang
    Yinghui Hua
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 3606 - 3610
  • [23] Metallic or bioabsorbable interference screw for graft fixation in anterior cruciate ligament (ACL) reconstruction?
    Papalia, Rocco
    Vasta, Sebastiano
    D'Adamio, Stefano
    Giacalone, Antonino
    Maffulli, Nicola
    Denaro, Vincenzo
    BRITISH MEDICAL BULLETIN, 2014, 109 (01) : 19 - 29
  • [24] Biomechanical Evaluation of TensionLoc Versus the Double Spike Plate for ACL Graft Tibial Fixation
    Jernick, Michael
    Borden, Peter S.
    Seager, Andorra
    McGarry, Michelle H.
    Adamson, Gregory J.
    Lee, Thay Q.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2023, 11 (05)
  • [25] Femoral Interference Screw Fixation in ACL Reconstruction Using Bone-Patellar Tendon-Bone Grafts
    Su, Charles A.
    Knapik, Derrick M.
    Trivedi, Nikunj N.
    Megerian, Mark F.
    Salata, Michael J.
    Voos, James E.
    JBJS REVIEWS, 2020, 8 (01)
  • [26] Primary stability with tibial press-fit fixation of patellar ligament graft: An experimental study in ovine knees
    Boszotta, H
    Anderl, W
    ARTHROSCOPY, 2001, 17 (09): : 963 - 970
  • [27] Interference screw fixation strength of a quadrupled hamstring tendon graft is directly related to bone mineral density and insertion torque
    Brand, JC
    Pienkowski, D
    Steenlage, E
    Hamilton, D
    Johnson, DL
    Caborn, DNM
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (05): : 705 - 710
  • [28] Biomechanical Comparison of a Novel Tibial Fixation Technique Versus Interference Screw Fixation for ACL Reconstruction Using Soft Tissue Grafts
    Sun, Tinghan
    Zhang, Hangzhou
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (08)
  • [29] Bioabsorbable interference screw versus bioabsorbable cross pins: influence of femoral graft fixation on the clinical outcome after ACL reconstruction
    Frosch, Stephan
    Rittstieg, Anne
    Balcarek, Peter
    Walde, Tim Alexander
    Schuettrumpf, Jan P.
    Wachowski, Martin M.
    Stuermer, Klaus M.
    Frosch, Karl-Heinz
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (11) : 2251 - 2256
  • [30] Metall-versus bioabsorbable polyglyconate interference screw for graft fixation in ACL reconstruction: a prospective randomized study of 40 patients
    Hackl, W
    Fink, C
    Benedetto, KP
    Hoser, C
    UNFALLCHIRURG, 2000, 103 (06): : 468 - 474