Bioabsorbable interference screw versus bioabsorbable cross pins: influence of femoral graft fixation on the clinical outcome after ACL reconstruction

被引:19
|
作者
Frosch, Stephan [1 ]
Rittstieg, Anne [1 ]
Balcarek, Peter [1 ]
Walde, Tim Alexander [1 ]
Schuettrumpf, Jan P. [1 ]
Wachowski, Martin M. [1 ]
Stuermer, Klaus M. [1 ]
Frosch, Karl-Heinz [1 ,2 ]
机构
[1] Med Univ Gottingen, Dept Trauma Surg Plast & Reconstruct Surg, Gottingen, Germany
[2] Asklepios Clin St Georg, Dept Trauma & Reconstruct Surg, Hamburg, Germany
关键词
Milagro screw; Interference screw; Cross pins; ACL reconstruction; Postoperative outcome; CRUCIATE LIGAMENT RECONSTRUCTION; PULLOUT STRENGTH; AUTOGRAFTS; INJURIES; TITANIUM;
D O I
10.1007/s00167-011-1875-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The aim of this study was to evaluate the clinical outcome and differences in anterior-posterior laxity of ACL reconstruction using a bioabsorbable interference screw for femoral graft fixation when compared to femoral bioabsorbable cross pin fixation. Clinical outcome was evaluated among 59 patients 1 year after arthroscopic ACL reconstruction with hamstrings graft in a prospective, non-randomised study. In 31 cases, femoral fixation of the graft was performed using a bioabsorbable interference screw. In 28 cases, two bioabsorbable cross pins were used for femoral fixation. Patients were evaluated using Tegner, Lysholm and Marshall scores, the visual analogue scale for pain and KT-1000 arthrometer measurement. No significant difference (P a parts per thousand yen 0.05) was observed at follow-up for the knee scores. The average Tegner score was 5.83 points (+/- 2.00) for the interference screw fixation and 5.83 points (+/- 1.24) for the cross pin fixation; the average Lysholm score was 93.58 (+/- 5.79) to 92.72 (+/- 6.34) points; and the average Marshall score 46.72 (+/- 2.4) to 47.30 (+/- 2.35) points. No significant difference was found for the visual analogue scale for pain. KT-1000 arthrometer measurement revealed a significant (P < 0.05) difference in the mean side-to-side anterior translation at all applied forces. At 67 N, the mean difference was 1.53 mm (+/- 1.24) in the interference screw group and 0.47 mm (+/- 1.18) in the cross pin group (P < 0.05). At 89 N, the mean differences were 1.85 mm (+/- 1.29) versus 0.59 mm (+/- 1.59), respectively, (P < 0.05), and maximum manual displacements were 2.02 mm (+/- 1.26) versus 1.22 mm (1.18; P < 0.05). In ACL reconstruction with hamstrings graft, similar clinical results are obtained for the use of bioabsorbable cross pins when compared to bioabsorbable interference screws for femoral fixation. Cross pin fixation was superior with regard to the anteroposterior laxity as measured with KT-1000.
引用
收藏
页码:2251 / 2256
页数:6
相关论文
共 50 条
  • [1] Bioabsorbable interference screw versus bioabsorbable cross pins: influence of femoral graft fixation on the clinical outcome after ACL reconstruction
    Stephan Frosch
    Anne Rittstieg
    Peter Balcarek
    Tim Alexander Walde
    Jan P. Schüttrumpf
    Martin M. Wachowski
    Klaus M. Stürmer
    Karl-Heinz Frosch
    Knee Surgery, Sports Traumatology, Arthroscopy, 2012, 20 : 2251 - 2256
  • [2] BIOMECHANICAL PERFORMANCE OF METALLIC AND BIOABSORBABLE INTERFERENCE SCREW FOR TIBIAL GRAFT FIXATION IN ACL RECONSTRUCTION
    Ocampo More, Ari Digiacomo
    Almeida Pizzolatti, Andre Luiz
    Fancello, Eduardo
    de Mello Roesler, Carlos Rodrigo
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT B, 2014,
  • [3] Metallic or bioabsorbable interference screw for graft fixation in anterior cruciate ligament (ACL) reconstruction?
    Papalia, Rocco
    Vasta, Sebastiano
    D'Adamio, Stefano
    Giacalone, Antonino
    Maffulli, Nicola
    Denaro, Vincenzo
    BRITISH MEDICAL BULLETIN, 2014, 109 (01) : 19 - 29
  • [4] Comparison between a novel human cortical bone screw and bioabsorbable interference screw for graft fixation of ACL reconstruction
    Shen, X. -Z.
    Qu, F.
    Li, C. -B.
    Qi, W.
    Lu, X.
    Li, H. -L.
    Guo, Q.
    Wang, J. -T.
    Zhao, G.
    Liu, Y. -J.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2018, 22 : 111 - 118
  • [5] Extra-articular Extraosselous Migration of a Bioabsorbable Femoral Interference Screw After ACL Reconstruction
    Sharma, Vivek
    Curtis, Christine
    Micheli, Lyle
    ORTHOPEDICS, 2008, 31 (10) : 1040 - 1040
  • [6] Tendon graft fixation in ACL reconstruction - In vitro evaluation of bioabsorbable tenodesis screw
    Klein, SA
    Nyland, J
    Kocabey, Y
    Wozniak, T
    Nawab, A
    Caborn, DNM
    ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (01): : 84 - 88
  • [7] Clinical outcome of anterior cruciate ligament reconstruction with quadrupled hamstring tendon graft and bioabsorbable interference screw fixation
    Charlton, WPH
    Randolph, DA
    Lemos, S
    Shields, CL
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2003, 31 (04): : 518 - 521
  • [8] Metall-versus bioabsorbable polyglyconate interference screw for graft fixation in ACL reconstruction: a prospective randomized study of 40 patients
    Hackl, W
    Fink, C
    Benedetto, KP
    Hoser, C
    UNFALLCHIRURG, 2000, 103 (06): : 468 - 474
  • [9] Comparison of the bioabsorbable and metal screw fixation after ACL reconstruction with a hamstring autograft in MRI and clinical outcome: a prospective randomized study
    Moisala, Anna-Stina
    Jarvela, Timo
    Paakkala, Antti
    Paakkala, Timo
    Kannus, Pekka
    Jarvinen, Markku
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2008, 16 (12) : 1080 - 1086
  • [10] Comparison of the bioabsorbable and metal screw fixation after ACL reconstruction with a hamstring autograft in MRI and clinical outcome: a prospective randomized study
    Anna-Stina Moisala
    Timo Järvelä
    Antti Paakkala
    Timo Paakkala
    Pekka Kannus
    Markku Järvinen
    Knee Surgery, Sports Traumatology, Arthroscopy, 2008, 16 : 1080 - 1086