Metall-versus bioabsorbable polyglyconate interference screw for graft fixation in ACL reconstruction: a prospective randomized study of 40 patients

被引:0
|
作者
Hackl, W [1 ]
Fink, C [1 ]
Benedetto, KP [1 ]
Hoser, C [1 ]
机构
[1] Univ Innsbruck, Unfallchirurg Klin, A-6020 Innsbruck, Austria
来源
UNFALLCHIRURG | 2000年 / 103卷 / 06期
关键词
anterior cruciate ligament reconstruction; interference screw; bioabsorbable implants;
D O I
10.1007/s001130050567
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
To overcome some of the potential problems (e.g. hardware removal during revision surgery) of metall interference screws used for patellar tendon anterior cruciate ligament reconstruction, bioabsorbable screws have recently been introduced. Forty patients who underwent endoscopic ACL reconstruction using patella tendon autograft were included in the study,they were randomized intraoperatively to either Group A (femoral bone block fixation: polyglyconate screw; tibial: metall screw) or Group B (both bone blocks fixed with metall interference screws). The patients were evaluated clinically preoperatively as well as 6 weeks, 3 months 12 months and 24 months post op. Lysholm Score at 24 months was 98,1+/-2,3 for Group A and 97,7+/-3,0 for Group B.Tegner Score was 7,4+/-1,1 for Group A and 7,5+/-0,8 for Group B. Two years post op overall IKDC-Score for group A was 5,6% normal, 88,8% nearly normal and 5,6% abnormal. The result for group B was 11,1%,77,8% and 11,1%, respectively. KT-1000 (at 89 N) at two years revealed a side to side difference of 1,5+/-0,3 mm (Group A) and 1,6+/-0,7 (Group B). The results of the two groups did not show significant differences at any stage of follow up. In our study polyglyconate interference screw fixation for patellar tendon grafts has not found to be associated with increased clinical complications. It provided equivalent fixation and clinical results compared to metall screws.
引用
收藏
页码:468 / 474
页数:7
相关论文
共 50 条
  • [1] Metall- versus bioabsorbable polyglyconate interference screw for graft fixation in ACL reconstruction: A prospective randomized study of 40 patients [Transplantatfixation bei der vorderen kreuzbandrekonstruktion. Metall- vs. bioresorbierbare polyglykonatinterferenzschraube - Eine prospektive randomisierte studie von 40 patienten]
    Hackl W.
    Fink C.
    Benedetto K.-P.
    Hoser C.
    Der Unfallchirurg, 2000, 103 (6): : 468 - 478
  • [2] Bioabsorbable interference screw versus bioabsorbable cross pins: influence of femoral graft fixation on the clinical outcome after ACL reconstruction
    Frosch, Stephan
    Rittstieg, Anne
    Balcarek, Peter
    Walde, Tim Alexander
    Schuettrumpf, Jan P.
    Wachowski, Martin M.
    Stuermer, Klaus M.
    Frosch, Karl-Heinz
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (11) : 2251 - 2256
  • [3] BIOMECHANICAL PERFORMANCE OF METALLIC AND BIOABSORBABLE INTERFERENCE SCREW FOR TIBIAL GRAFT FIXATION IN ACL RECONSTRUCTION
    Ocampo More, Ari Digiacomo
    Almeida Pizzolatti, Andre Luiz
    Fancello, Eduardo
    de Mello Roesler, Carlos Rodrigo
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT B, 2014,
  • [4] Bioabsorbable interference screw versus bioabsorbable cross pins: influence of femoral graft fixation on the clinical outcome after ACL reconstruction
    Stephan Frosch
    Anne Rittstieg
    Peter Balcarek
    Tim Alexander Walde
    Jan P. Schüttrumpf
    Martin M. Wachowski
    Klaus M. Stürmer
    Karl-Heinz Frosch
    Knee Surgery, Sports Traumatology, Arthroscopy, 2012, 20 : 2251 - 2256
  • [5] Metallic or bioabsorbable interference screw for graft fixation in anterior cruciate ligament (ACL) reconstruction?
    Papalia, Rocco
    Vasta, Sebastiano
    D'Adamio, Stefano
    Giacalone, Antonino
    Maffulli, Nicola
    Denaro, Vincenzo
    BRITISH MEDICAL BULLETIN, 2014, 109 (01) : 19 - 29
  • [6] Bioabsorbable polyglyconate interference screw fixation in anterior cruciate ligament reconstruction: A prospective computed tomography-controlled study
    Fink, C
    Benedetto, KP
    Hackl, W
    Hoser, C
    Freund, MC
    Rieger, M
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2000, 16 (05): : 491 - 498
  • [7] Comparison between a novel human cortical bone screw and bioabsorbable interference screw for graft fixation of ACL reconstruction
    Shen, X. -Z.
    Qu, F.
    Li, C. -B.
    Qi, W.
    Lu, X.
    Li, H. -L.
    Guo, Q.
    Wang, J. -T.
    Zhao, G.
    Liu, Y. -J.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2018, 22 : 111 - 118
  • [8] Tendon graft fixation in ACL reconstruction - In vitro evaluation of bioabsorbable tenodesis screw
    Klein, SA
    Nyland, J
    Kocabey, Y
    Wozniak, T
    Nawab, A
    Caborn, DNM
    ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (01): : 84 - 88
  • [9] Comparison of the bioabsorbable and metal screw fixation after ACL reconstruction with a hamstring autograft in MRI and clinical outcome: a prospective randomized study
    Moisala, Anna-Stina
    Jarvela, Timo
    Paakkala, Antti
    Paakkala, Timo
    Kannus, Pekka
    Jarvinen, Markku
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2008, 16 (12) : 1080 - 1086
  • [10] Comparison of the bioabsorbable and metal screw fixation after ACL reconstruction with a hamstring autograft in MRI and clinical outcome: a prospective randomized study
    Anna-Stina Moisala
    Timo Järvelä
    Antti Paakkala
    Timo Paakkala
    Pekka Kannus
    Markku Järvinen
    Knee Surgery, Sports Traumatology, Arthroscopy, 2008, 16 : 1080 - 1086