Metall-versus bioabsorbable polyglyconate interference screw for graft fixation in ACL reconstruction: a prospective randomized study of 40 patients

被引:0
|
作者
Hackl, W [1 ]
Fink, C [1 ]
Benedetto, KP [1 ]
Hoser, C [1 ]
机构
[1] Univ Innsbruck, Unfallchirurg Klin, A-6020 Innsbruck, Austria
来源
UNFALLCHIRURG | 2000年 / 103卷 / 06期
关键词
anterior cruciate ligament reconstruction; interference screw; bioabsorbable implants;
D O I
10.1007/s001130050567
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
To overcome some of the potential problems (e.g. hardware removal during revision surgery) of metall interference screws used for patellar tendon anterior cruciate ligament reconstruction, bioabsorbable screws have recently been introduced. Forty patients who underwent endoscopic ACL reconstruction using patella tendon autograft were included in the study,they were randomized intraoperatively to either Group A (femoral bone block fixation: polyglyconate screw; tibial: metall screw) or Group B (both bone blocks fixed with metall interference screws). The patients were evaluated clinically preoperatively as well as 6 weeks, 3 months 12 months and 24 months post op. Lysholm Score at 24 months was 98,1+/-2,3 for Group A and 97,7+/-3,0 for Group B.Tegner Score was 7,4+/-1,1 for Group A and 7,5+/-0,8 for Group B. Two years post op overall IKDC-Score for group A was 5,6% normal, 88,8% nearly normal and 5,6% abnormal. The result for group B was 11,1%,77,8% and 11,1%, respectively. KT-1000 (at 89 N) at two years revealed a side to side difference of 1,5+/-0,3 mm (Group A) and 1,6+/-0,7 (Group B). The results of the two groups did not show significant differences at any stage of follow up. In our study polyglyconate interference screw fixation for patellar tendon grafts has not found to be associated with increased clinical complications. It provided equivalent fixation and clinical results compared to metall screws.
引用
收藏
页码:468 / 474
页数:7
相关论文
共 50 条
  • [21] Resorbable screw and sheath versus resorbable interference screw and staples for ACL reconstruction: a comparison of two tibial fixation methods
    Christian Carulli
    Fabrizio Matassi
    Stefano Soderi
    Luigi Sirleo
    Giovanni Munz
    Massimo Innocenti
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 1264 - 1271
  • [22] Resorbable screw and sheath versus resorbable interference screw and staples for ACL reconstruction: a comparison of two tibial fixation methods
    Carulli, Christian
    Matassi, Fabrizio
    Soderi, Stefano
    Sirleo, Luigi
    Munz, Giovanni
    Innocenti, Massimo
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (04) : 1264 - 1271
  • [23] Pullout strength of tibial graft fixation in ACL-replacement with a patellar tendon graft: Interference screw versus staple fixation in human knees
    Gerich, TG
    Cassim, A
    Lattermann, C
    Lobenhoffer, HP
    Tscherne, H
    UNFALLCHIRURG, 1998, 101 (03): : 204 - 208
  • [24] Magnetic resonance imaging analysis of the bioabsorbable Milagro (TM) interference screw for graft fixation in anterior cruciate ligament reconstruction
    Frosch, K. -H.
    Sawallich, T.
    Schuetze, G.
    Losch, A.
    Walde, T.
    Balcarek, P.
    Konietschke, F.
    Stuermer, K. M.
    STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2009, 4 (02): : 73 - 79
  • [25] Biomechanical Comparison of a Novel Tibial Fixation Technique Versus Interference Screw Fixation for ACL Reconstruction Using Soft Tissue Grafts
    Sun, Tinghan
    Zhang, Hangzhou
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (08)
  • [26] Mechanical Evaluation of Bone-Patellar Tendon-Bone Graft Fixation to the Tibia in ACL Reconstruction: Bone Plug Tensioning and Fixation System versus Interference Screw
    Iuchi, Ryo
    Shino, Konsei
    Mae, Tatsuo
    Yamakawa, Satoshi
    Nakata, Ken
    JOURNAL OF KNEE SURGERY, 2024, 37 (13) : 894 - 901
  • [27] ACL reconstruction with quadriceps tendon graft and press-fit fixation versus quadruple hamstring graft and interference screw fixation – a matched pair analysis after one year follow up
    Ralph Akoto
    Malte Albers
    Maurice Balke
    Bertil Bouillon
    Jürgen Höher
    BMC Musculoskeletal Disorders, 20
  • [28] ACL reconstruction with quadriceps tendon graft and press-fit fixation versus quadruple hamstring graft and interference screw fixation - a matched pair analysis after one year follow up
    Akoto, Ralph
    Albers, Malte
    Balke, Maurice
    Bouillon, Bertil
    Hoeher, Juergen
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (1)
  • [29] Biomechanical evaluation of a bioabsorbable expansion bolt for hamstring graft fixation in ACL reconstruction: an experimental study in calf tibial bone
    Piltz, S
    Dieckmann, R
    Meyer, L
    Strunk, P
    Plitz, W
    Lob, G
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2005, 125 (09) : 577 - 584
  • [30] Biomechanical evaluation of a bioabsorbable expansion bolt for hamstring graft fixation in ACL reconstruction: an experimental study in calf tibial bone
    S. Piltz
    R. Dieckmann
    L. Meyer
    P. Strunk
    W. Plitz
    G. Lob
    Archives of Orthopaedic and Trauma Surgery, 2005, 125 : 577 - 584