Metall-versus bioabsorbable polyglyconate interference screw for graft fixation in ACL reconstruction: a prospective randomized study of 40 patients

被引:0
|
作者
Hackl, W [1 ]
Fink, C [1 ]
Benedetto, KP [1 ]
Hoser, C [1 ]
机构
[1] Univ Innsbruck, Unfallchirurg Klin, A-6020 Innsbruck, Austria
来源
UNFALLCHIRURG | 2000年 / 103卷 / 06期
关键词
anterior cruciate ligament reconstruction; interference screw; bioabsorbable implants;
D O I
10.1007/s001130050567
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
To overcome some of the potential problems (e.g. hardware removal during revision surgery) of metall interference screws used for patellar tendon anterior cruciate ligament reconstruction, bioabsorbable screws have recently been introduced. Forty patients who underwent endoscopic ACL reconstruction using patella tendon autograft were included in the study,they were randomized intraoperatively to either Group A (femoral bone block fixation: polyglyconate screw; tibial: metall screw) or Group B (both bone blocks fixed with metall interference screws). The patients were evaluated clinically preoperatively as well as 6 weeks, 3 months 12 months and 24 months post op. Lysholm Score at 24 months was 98,1+/-2,3 for Group A and 97,7+/-3,0 for Group B.Tegner Score was 7,4+/-1,1 for Group A and 7,5+/-0,8 for Group B. Two years post op overall IKDC-Score for group A was 5,6% normal, 88,8% nearly normal and 5,6% abnormal. The result for group B was 11,1%,77,8% and 11,1%, respectively. KT-1000 (at 89 N) at two years revealed a side to side difference of 1,5+/-0,3 mm (Group A) and 1,6+/-0,7 (Group B). The results of the two groups did not show significant differences at any stage of follow up. In our study polyglyconate interference screw fixation for patellar tendon grafts has not found to be associated with increased clinical complications. It provided equivalent fixation and clinical results compared to metall screws.
引用
收藏
页码:468 / 474
页数:7
相关论文
共 50 条
  • [31] Broken Bioabsorbable Tibial Interference Screw after Anterior Cruciate Ligament (ACL) Reconstruction using a Semitendinosus-gracilis Graft: A Case Report
    Deborah, Huang M. E.
    Andrew, Tan H. C.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2012, 6 (02) : 42 - 44
  • [32] Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study
    Herrera, Antonio
    Martinez, Fernando
    Iglesias, Daniel
    Cegonino, Jose
    Ibarz, Elena
    Gracia, Luis
    BMC MUSCULOSKELETAL DISORDERS, 2010, 11
  • [33] Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study
    Antonio Herrera
    Fernando Martínez
    Daniel Iglesias
    José Cegoñino
    Elena Ibarz
    Luis Gracia
    BMC Musculoskeletal Disorders, 11
  • [34] Pullout strength of tibial graft fixation in ACL-replacement with a patellar tendon graft: Interference screw versus staple fixation in human kneesInterferenzschrauben vs. Staples
    T. G. Gerich
    A. Cassim
    C. Lattermann
    H. P. Lobenhoffer
    H. Tscherne
    Der Unfallchirurg, 1998, 101 : 204 - 208
  • [35] Prospective evaluation of patellar tendon graft fixation in anterior cruciate ligament reconstruction comparing composite bioabsorbable and allograft interference screws
    Tecklenburg, Katja
    Burkart, Peter
    Hoser, Christian
    Rieger, Michael
    Fink, Christian
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (09): : 993 - 999
  • [36] A prospective randomized study of arthroscopic ACL reconstruction with adjustable- versus fixed-loop device for femoral side fixation
    Asif, Naiyer
    Khan, Mohammad Jesan
    Haris, K. P.
    Waliullah, Shah
    Sharma, Anubhav
    Firoz, Danish
    KNEE SURGERY & RELATED RESEARCH, 2021, 33 (01)
  • [37] A prospective randomized study of arthroscopic ACL reconstruction with adjustable- versus fixed-loop device for femoral side fixation
    Naiyer Asif
    Mohammad Jesan Khan
    K. P. Haris
    Shah Waliullah
    Anubhav Sharma
    Danish Firoz
    Knee Surgery & Related Research, 33
  • [38] Tibial Fixation in Anterior Cruciate Ligament Reconstruction A Prospective Randomized Study Comparing Metal Interference Screw and Staples With a Centrally Placed Polyethylene Screw and Sheath
    De Wall, Mathew
    Scholes, Corey J.
    Patel, Sandeep
    Coolican, Myles R. J.
    Parker, David A.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2011, 39 (09): : 1858 - 1864
  • [39] Bioabsorbable versus stainless steel screw fixation of the syndesmosis in pronation-lateral rotation ankle fractures: A prospective randomized trial
    Thordarson, DB
    Samuelson, M
    Shepherd, LE
    Merkle, PF
    Lee, J
    FOOT & ANKLE INTERNATIONAL, 2001, 22 (04) : 335 - 338
  • [40] Two ulnar collateral ligament reconstruction methods: The docking technique versus bioabsorbable interference screw fixation - A biomechanical evaluation with cyclic loading
    McAdams, Timothy R.
    Lee, Arthur T.
    Centeno, Joseph
    Giori, Nicholas J.
    Lindsey, Derek P.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (02) : 224 - 228