Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study

被引:24
|
作者
Herrera, Antonio [1 ,2 ]
Martinez, Fernando [1 ]
Iglesias, Daniel [1 ]
Cegonino, Jose [3 ]
Ibarz, Elena [3 ]
Gracia, Luis [3 ]
机构
[1] Miguel Servet Univ Hosp, Aragon Hlth Sci Inst, Dept Orthopaed Surg & Traumatol, Zaragoza, Spain
[2] Univ Zaragoza, Dept Surg, E-50009 Zaragoza, Spain
[3] Univ Zaragoza, Dept Mech Engn, E-50009 Zaragoza, Spain
来源
BMC MUSCULOSKELETAL DISORDERS | 2010年 / 11卷
关键词
ANTERIOR CRUCIATE LIGAMENT; HAMSTRING TENDON GRAFTS; PATELLAR TENDON; PULLOUT STRENGTH; INSERTION TORQUE; BIOMECHANICAL EVALUATION; FEMORAL TUNNEL; BONE-GRAFTS; SEMITENDINOSUS; DIAMETER;
D O I
10.1186/1471-2474-11-139
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Primary stability of the graft is essential in anterior cruciate ligament surgery. An optimal method of fixation should be easy to insert and provide great resistance against pull-out forces. A controlled laboratory study was designed to test the primary stability of ACL tendinous grafts in the tibial tunnel. The correlation between resistance to traction forces and the cross-section and length of the screw was studied. Methods: The tibial phase of ACL reconstruction was performed in forty porcine tibias using digital flexor tendons of the same animal. An 8 mm tunnel was drilled in each specimen and two looped tendons placed as graft. Specimens were divided in five groups according to the diameter and length of the screw used for fixation. Wedge interference screws were used. Longitudinal traction was applied to the graft with a Servohydraulic Fatigue System. Load and displacement were controlled and analyzed. Results: The mean loads to failure for each group were 295,44 N (Group 1; 9 x 23 screw), 564,05 N (Group 2; 9 x 28), 614,95 N (Group 3; 9 x 35), 651,14 N (Group 4; 10 x 28) and 664,99 (Group 5; 10 x 35). No slippage of the graft was observed in groups 3, 4 and 5. There were significant differences in the load to failure among groups (ANOVA/P < 0.001). Conclusions: Longer and wider interference screws provide better fixation in tibial ACL graft fixation. Short screws (23 mm) do not achieve optimal fixation and should be implanted only with special requirements.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study
    Antonio Herrera
    Fernando Martínez
    Daniel Iglesias
    José Cegoñino
    Elena Ibarz
    Luis Gracia
    BMC Musculoskeletal Disorders, 11
  • [2] Effect of screw length on bioabsorbable interference screw fixation in a tibial bone tunnel
    Selby, JB
    Johnson, DL
    Hester, P
    Caborn, DNM
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2001, 29 (05): : 614 - 619
  • [3] Effect of Interference Screw Fixation on ACL Graft Tensile Strength
    Sawyer, Gregory A.
    Anderson, Brett C.
    Paller, David
    Heard, Wendell Malcolm Rogan
    Fadale, Paul D.
    JOURNAL OF KNEE SURGERY, 2013, 26 (03) : 155 - 159
  • [4] Fixation strength of the interference screw in the femoral tunnel: The effect of screw divergence on the coronal plane
    Ninomiya, Tadaaki
    Tachibana, Yomei
    Miyajima, Tsuyoshi
    Yamazaki, Katsuhiko
    Oda, Hiromi
    KNEE, 2011, 18 (02): : 83 - 87
  • [5] Resorption characteristics of an open architecture biocomposite interference screw after ACL reconstruction
    Lind, Martin
    Nielsen, Torsten Gronbech
    Nielsen, Flemming K.
    Sorensen, Ole G.
    Mygind-Klavsen, Bjarne
    Fauno, Peter
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (04)
  • [6] Femoral interference screw fixation of hamstring and quadriceps tendons for ACL reconstruction
    M. Ettinger
    T. Werner-Lebeda
    T. Calliess
    M. Omar
    C. Becher
    M. Ezechieli
    M. Klintschar
    M. Petri
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 (4) : 1241 - 1248
  • [7] Femoral interference screw fixation of hamstring and quadriceps tendons for ACL reconstruction
    Ettinger, M.
    Werner-Lebeda, T.
    Calliess, T.
    Omar, M.
    Becher, C.
    Ezechieli, M.
    Klintschar, M.
    Petri, M.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (04) : 1241 - 1248
  • [8] Comparison between a novel human cortical bone screw and bioabsorbable interference screw for graft fixation of ACL reconstruction
    Shen, X. -Z.
    Qu, F.
    Li, C. -B.
    Qi, W.
    Lu, X.
    Li, H. -L.
    Guo, Q.
    Wang, J. -T.
    Zhao, G.
    Liu, Y. -J.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2018, 22 : 111 - 118
  • [9] MRI evaluation of the tibial tunnel/screw/tendon interface after ACL reconstruction using a bioabsorbable interference screw
    Singhal, Manuj C.
    Holzhauer, Markus
    Powell, David
    Johnson, Darren L.
    ORTHOPEDICS, 2008, 31 (06) : 575 - 579
  • [10] ACL reconstruction with adjustable-length loop cortical button fixation results in less tibial tunnel widening compared with interference screw fixation
    Raul Mayr
    Vinzenz Smekal
    Christian Koidl
    Christian Coppola
    Martin Eichinger
    Ansgar Rudisch
    Christof Kranewitter
    René Attal
    Knee Surgery, Sports Traumatology, Arthroscopy, 2020, 28 : 1036 - 1044