Effect of Interference Screw Fixation on ACL Graft Tensile Strength

被引:23
|
作者
Sawyer, Gregory A. [1 ]
Anderson, Brett C. [2 ]
Paller, David [1 ]
Heard, Wendell Malcolm Rogan [3 ]
Fadale, Paul D. [1 ]
机构
[1] Rhode Isl Hosp, Brown Med Sch, Dept Orthopaed Surg, Providence, RI 02903 USA
[2] US Air Force Acad, Dept Orthopaed Surg & Sports Med, Colorado Springs, CO 80840 USA
[3] Rush Univ, Med Ctr, Dept Orthopaed Surg & Sports Med, Chicago, IL 60612 USA
关键词
anterior cruciate ligament; reconstruction; laceration; interference screw; ANTERIOR CRUCIATE LIGAMENT; HAMSTRING TENDON GRAFT; PULL-OUT; RECONSTRUCTION; BONE; AUTOGRAFT; STABILITY;
D O I
10.1055/s-0032-1324808
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Tibial-sided fixation of soft tissue grafts in anterior cruciate ligament (ACL) reconstruction has often been identified as the weak link in the fixation construct, with interference screws being a commonly used technique. A significant concern surrounding the use of interference screws for soft tissue fixation is graft laceration and the possibility of loss of pull-out strength and slippage. The act of interference screw insertion for soft tissue graft fixation in ACL reconstruction alters the biomechanical properties of the graft. Two groups of 12 porcine knees (24 total) were utilized for the tibial-sided fixation of porcine flexor digitorum tendons using single-insertion interference screws, in a model of soft tissue ACL reconstruction. Two different screw types were used for comparison. Following screw insertion, the grafts were dissected free and underwent biomechanical testing in tension to failure. Control flexor digitorum tendons underwent the same biomechanical testing for comparison. Control soft tissue grafts exhibited significantly higher yield load, ultimate load, and stiffness (p < 0.001) in comparison to both groups of treated grafts, without evidence of significant macroscopic damage. Single insertion of interference screws for soft tissue graft fixation in ACL reconstruction weakens the biomechanical properties of the graft itself.
引用
收藏
页码:155 / 159
页数:5
相关论文
共 50 条
  • [1] Pullout strength of tibial graft fixation in ACL-replacement with a patellar tendon graft: Interference screw versus staple fixation in human knees
    Gerich, TG
    Cassim, A
    Lattermann, C
    Lobenhoffer, HP
    Tscherne, H
    UNFALLCHIRURG, 1998, 101 (03): : 204 - 208
  • [2] Metallic or bioabsorbable interference screw for graft fixation in anterior cruciate ligament (ACL) reconstruction?
    Papalia, Rocco
    Vasta, Sebastiano
    D'Adamio, Stefano
    Giacalone, Antonino
    Maffulli, Nicola
    Denaro, Vincenzo
    BRITISH MEDICAL BULLETIN, 2014, 109 (01) : 19 - 29
  • [3] BIOMECHANICAL PERFORMANCE OF METALLIC AND BIOABSORBABLE INTERFERENCE SCREW FOR TIBIAL GRAFT FIXATION IN ACL RECONSTRUCTION
    Ocampo More, Ari Digiacomo
    Almeida Pizzolatti, Andre Luiz
    Fancello, Eduardo
    de Mello Roesler, Carlos Rodrigo
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT B, 2014,
  • [4] Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study
    Herrera, Antonio
    Martinez, Fernando
    Iglesias, Daniel
    Cegonino, Jose
    Ibarz, Elena
    Gracia, Luis
    BMC MUSCULOSKELETAL DISORDERS, 2010, 11
  • [5] Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study
    Antonio Herrera
    Fernando Martínez
    Daniel Iglesias
    José Cegoñino
    Elena Ibarz
    Luis Gracia
    BMC Musculoskeletal Disorders, 11
  • [6] Comparison between a novel human cortical bone screw and bioabsorbable interference screw for graft fixation of ACL reconstruction
    Shen, X. -Z.
    Qu, F.
    Li, C. -B.
    Qi, W.
    Lu, X.
    Li, H. -L.
    Guo, Q.
    Wang, J. -T.
    Zhao, G.
    Liu, Y. -J.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2018, 22 : 111 - 118
  • [7] Pullout strength of tibial graft fixation in ACL-replacement with a patellar tendon graft: Interference screw versus staple fixation in human kneesInterferenzschrauben vs. Staples
    T. G. Gerich
    A. Cassim
    C. Lattermann
    H. P. Lobenhoffer
    H. Tscherne
    Der Unfallchirurg, 1998, 101 : 204 - 208
  • [8] Interference screw insertion angle has no effect on graft fixation strength for insertional Achilles tendon reconstruction
    Ziying Wu
    Hongyun Li
    Shiyi Chen
    Kui Ma
    Shengkun Li
    Peng Zhang
    Yinghui Hua
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 3606 - 3610
  • [9] Interference screw insertion angle has no effect on graft fixation strength for insertional Achilles tendon reconstruction
    Wu, Ziying
    Li, Hongyun
    Chen, Shiyi
    Ma, Kui
    Li, Shengkun
    Zhang, Peng
    Hua, Yinghui
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (12) : 3606 - 3610
  • [10] Effect of Interference Screw Depth on Fixation Strength in Biceps Tenodesis
    Salata, Michael J.
    Bailey, James R.
    Bell, Rebecca
    Frank, Rachel M.
    McGill, Kevin C.
    Lin, Emery C.
    Kercher, James S.
    Wang, Vincent M.
    Provencher, Matthew T.
    Mazzocca, Augustus D.
    Verma, Nikhil N.
    Romeo, Anthony A.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2014, 30 (01): : 11 - 15