Femoral interference screw fixation of hamstring and quadriceps tendons for ACL reconstruction

被引:9
|
作者
Ettinger, M. [1 ]
Werner-Lebeda, T. [1 ]
Calliess, T. [1 ]
Omar, M. [2 ]
Becher, C. [1 ]
Ezechieli, M. [1 ]
Klintschar, M. [3 ]
Petri, M. [2 ]
机构
[1] Hannover Med Sch MHH, Dept Orthopaed Surg, Anna von Borries Str 1-7, D-30625 Hannover, Germany
[2] Hannover Med Sch MHH, Trauma Dept, Carl Neuberg Str 1, D-30625 Hannover, Germany
[3] Hannover Med Sch MHH, Inst Legal Med, Carl Neuberg Str 1, D-30625 Hannover, Germany
关键词
Anterior cruciate ligament; Anterior cruciate ligament reconstruction; Femoral fixation; Interference screw; Quadriceps tendon graft; Hamstring tendon graft; Biomechanics; ANTERIOR CRUCIATE LIGAMENT; PRESS-FIT FIXATION; GRAFT FIXATION; BONE TUNNEL; PATELLAR TENDON; BIOMECHANICAL EVALUATION; SITE MORBIDITY; PART II; STRENGTH; AUTOGRAFT;
D O I
10.1007/s00167-016-4001-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This cadaveric study compares the biomechanical properties of femoral graft fixation in ACL reconstruction of either quadriceps or hamstring tendon grafts with four different interference screws. The hypothesis was that quadriceps tendon grafts provide at least equal results concerning gap formation during cyclic loading and ultimate failure load compared to hamstring tendon grafts with four different interference screws. Eighty porcine femora underwent interference screw fixation of human tendon grafts for ACL reconstruction. Either quadriceps (Q) or hamstring (H) tendon grafts and four different bioabsorbable interference (Wolf (W), Storz (S), Mitek (M), Arthrex (A)) screws were used, resulting in 8 groups with 10 specimens per groups (WQ, WH, SQ, SH, MQ, MH, AQ, AH). Biomechanical analysis included pretensioning the constructs with 60 N for 30 s, then cyclic loading of 500 cycles between 60 and 250 N at 1 Hz in a servohydraulic testing machine, with measurement of elongation and stiffness including video measurements. After this, ultimate failure load and failure mode analysis were performed. No statistically significant difference could be noted between the groups regarding gap formation during cyclic loading [Cycles 21-500 (mm): WQ 3.6 +/- 0.8, WH 3.9 +/- 1.4, SQ 3.6 +/- 0.8, SH 3.3 +/- 1.5, MQ 4.3 +/- 0.8, MH 4.6 +/- 1.0, AQ 4.8 +/- 0.8, AH 4.3 +/- 1.5, n.s.], stiffness during cyclic loading [Cycles 21-500 (N/mm): WQ 72.9 +/- 16.9, WH 71.6 +/- 20.7, SQ 69.5 +/- 23.9, SH 77.4 +/- 25.1, MQ 59.6 +/- 11.2, MH 48.4 +/- 15.4, AQ 48.8 +/- 12.7, AH 51.9 +/- 22.2, n.s.], and ultimate failure load [(N): WQ 474.4 +/- 88.0, WH 579.3 +/- 124.2, SQ 493.9 +/- 105.2, SH 576.0 +/- 90.4, MQ 478.6 +/- 59.0, MH 543.9 +/- 119.7, AQ 480.2 +/- 93.8, AH 497.8 +/- 74.2, n.s.]. Quadriceps tendon grafts yield comparable biomechanical results for femoral interference screw fixation in ACL reconstruction compared to hamstring tendon grafts. From a clinical perspective, quadriceps tendon grafts should therefore be considered as a good option in ACL reconstruction in the future.
引用
收藏
页码:1241 / 1248
页数:8
相关论文
共 50 条
  • [1] Femoral interference screw fixation of hamstring and quadriceps tendons for ACL reconstruction
    M. Ettinger
    T. Werner-Lebeda
    T. Calliess
    M. Omar
    C. Becher
    M. Ezechieli
    M. Klintschar
    M. Petri
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 (4) : 1241 - 1248
  • [2] The fixation of hamstring tendons in ACL reconstruction
    Aglietti, P
    Giron, F
    6TH WORLD CONGRESS OF ENDOSCOPIC SURGERY, PTS 1 AND 2, 1998, : 695 - 700
  • [3] No difference in clinical results between femoral transfixation and bio-interference screw fixation in hamstring tendon ACL reconstruction - A preliminary study
    Capuano, Luca
    Hardy, Philippe
    Longo, Umile Giuseppe
    Denaro, Vincenzo
    Maffulli, Nicola
    KNEE, 2008, 15 (03): : 174 - 179
  • [4] Hyperflexion and Femoral Interference Screw Insertion in ACL Reconstruction
    Steiner, Mark E.
    Wing, David
    Walley, Kempland C.
    Manoukian, Ohan
    Perez-Viloria, Miguel
    Okajima, Stephen
    Nazarian, Ara
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2018, 6 (08)
  • [5] Tibial press-fit fixation of the hamstring tendons for ACL-reconstruction
    M. Jagodzinski
    K. Scheunemann
    K. Knobloch
    K. Albrecht
    C. Krettek
    C. Hurschler
    J. Zeichen
    Knee Surgery, Sports Traumatology, Arthroscopy, 2006, 14 : 1281 - 1287
  • [6] Biosteon Cross Pin Femoral Fixation and Tibial Interference Screw Fixation for Hamstring Anterior Cruciate Ligament Reconstruction
    Stewart, Andrew M.
    Paulos, Lonnie E.
    TECHNIQUES IN ORTHOPAEDICS, 2005, 20 (03) : 254 - 260
  • [7] Tibial press-fit fixation of the hamstring tendons for ACL-reconstruction
    Jagodzinski, M.
    Scheunemann, K.
    Knobloch, K.
    Albrecht, K.
    Krettek, C.
    Hurschler, C.
    Zeichen, J.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (12) : 1281 - 1287
  • [8] Interference screw position and hamstring graft location for ACL reconstruction.
    Simonian, PT
    Sussmann, PS
    Baldini, TH
    Crockett, HC
    Wickiewicz, TL
    ARTHROSCOPY, 1998, 14 (04): : 447 - 448
  • [9] Metal interference screw fixation combinations show high revision rates in primary hamstring tendon ACL reconstruction
    Janina Kaarre
    Neilen A. Benvegnu
    Ian D. Engler
    Ehab M. Nazzal
    Bálint Zsidai
    Eric Hamrin Senorski
    Volker Musahl
    Kristian Samuelsson
    BMC Musculoskeletal Disorders, 25
  • [10] Metal interference screw fixation combinations show high revision rates in primary hamstring tendon ACL reconstruction
    Kaarre, Janina
    Benvegnu, Neilen A.
    Engler, Ian D.
    Nazzal, Ehab M.
    Zsidai, Balint
    Senorski, Eric Hamrin
    Musahl, Volker
    Samuelsson, Kristian
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)