Less invasive aortic valve replacement using the trifecta bioprosthesis

被引:2
|
作者
Agnino, Alfonso [1 ,2 ]
Graniero, Ascanio [1 ,2 ]
Gerometta, Piersilvio [1 ]
Giroletti, Laura [1 ,2 ]
Albano, Giovanni [3 ]
Roscitano, Claudio [3 ]
Anselmi, Amedeo [4 ]
机构
[1] Clin Humanitas Gavazzeni, Cardiovasc Dept, Bergamo, Italy
[2] Clin Humanitas Gavazzeni, Div Robot & Minimally Invas Cardiac Surg, Bergamo, Italy
[3] Clin Humanitas Gavazzeni, Div Cardiac Anesthesia, Bergamo, Italy
[4] Pontchaillou Univ Hosp, Div Thorac & Cardiovasc Surg, 2 Rue Henri le Guilloux, F-35000 Rennes, France
关键词
Aortic valve replacement; less invasive surgery; hemodynamics; outcomes; HEMODYNAMIC PERFORMANCE; PORCINE BIOPROSTHESIS; MIDTERM DURABILITY; MULTICENTER; MINISTERNOTOMY; MORTALITY;
D O I
10.1080/14017431.2022.2071460
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The safety and effectiveness of the Trifecta GT bioprosthesis (introduced in 2016) in less invasive aortic valve replacement are scarcely investigated. Our aim was to evaluate the immediate and initial follow-up results of this device in the context of less invasive surgery. We discuss patient-specific strategies for the selection of the surgical approach. Methods. A retrospective review of 133 patients undergoing AVR with the Trifecta GT through three less invasive accesses (UMS, Upper ministernotomy; RMS, Reversed ministernotomy; RAMT, Right anterior minithoracotomy) was performed. In-hospital, follow-up and hemodynamic performance (PPM, Patient-prosthesis mismatch) data were collected. Results. Among patients, 79% received UMS, 11% RMS and 10% RAMT. Selection of approach was based on preoperative anatomical analysis (CT-scan) and planned concomitant procedures. There was no operative mortality, no valve-related adverse events. There were 36 concomitant procedures. No significant intergroup differences occurred in cardiopulmonary bypass, aortic clamp, mechanical ventilation time, ICU stay and average bleeding. There were two cases of moderate PPM (1.5%) and no instances of severe PPM; there were no significant (>= 2/4) perivalvular leaks. Average mean gradient at discharge was 8 +/- 3 mmHg. At follow-up (average: 2.5 +/- 0.9 years, 100% complete, 315 patient years) there was no mortality and no valve-related adverse event. Hemodynamic performance was maintained at follow-up. Conclusions. The optimal device for less invasive AVR needs to be individualized, as well as the selection of the surgical approach. The use of the Trifecta GT bioprosthesis appears to be reproductible whatever less invasive approach is employed, with confirmed excellent hemodynamic performance.
引用
收藏
页码:79 / 84
页数:6
相关论文
共 50 条
  • [21] Early structural valve deterioration of a Trifecta bioprosthesis: a minimally invasive redo approach
    Gavalaki, Aikaterini
    Roussakis, Antonios
    Perreas, Konstantinos
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2020, 57 (06) : 1228 - 1228
  • [22] AORTIC-VALVE REPLACEMENT BY BIOPROSTHESIS WITH ENLARGEMENT OF THE AORTIC RING
    LESSANA, A
    AMEUR, A
    DUPRADEL, S
    RUFFENACH, A
    ADES, F
    LEFEVRE, JJ
    SVILARICH, V
    HERREMAN, F
    VIET, TT
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1984, 77 (03): : 324 - 329
  • [23] AORTIC-VALVE REPLACEMENT WITH STENTLESS PORCINE AORTIC BIOPROSTHESIS
    DAVID, TE
    POLLICK, C
    BOS, J
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1990, 99 (01): : 113 - 118
  • [24] Successful transcatheter aortic valve in valve implantation for degenerated trifecta bioprosthesis in a patient with a coronary anomaly
    Akiko Yamagata
    Satoru Domoto
    Kazuki Tanaka
    Yusuke Inagaki
    Hisao Otsuki
    Minako Hayakawa
    Junichi Yamaguchi
    Nobuhisa Hagiwara
    Hiroshi Niinami
    General Thoracic and Cardiovascular Surgery, 2021, 69 : 1137 - 1139
  • [25] Ten years follow-up after aortic valve replacement with bioprosthesis trifecta: a single center retrospective cohort
    Goncalves, C.
    Cerqueira, R.
    Araujo, J.
    Moreira, S.
    Palma, P.
    Almeida, J.
    Amorim, M. J.
    Pinho, P.
    Diaz, S. O.
    Barros, A. S.
    Lourenco, A. P.
    Saraiva, F.
    Leite-Moreira, A.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [26] Comparison of outcomes after aortic valve replacement with a mechanical valve or a bioprosthesis using microsimulation
    Puvimanasinghe, JPA
    Takkenberg, JJM
    Edwards, MB
    Eijkemans, MJC
    Steyerberg, EW
    van Herwerden, LA
    Taylor, KM
    Grunkemeier, GL
    Habbema, JDF
    Bogers, AJJC
    HEART, 2004, 90 (10) : 1172 - 1178
  • [27] Midterm results after aortic valve replacement with a stentless bioprosthesis aortic valve
    Martinovic, I
    Everlien, M
    Farah, I
    Wittlinger, T
    Knez, I
    Greve, H
    Vogt, P
    ANNALS OF THORACIC SURGERY, 2005, 80 (01): : 198 - 203
  • [28] Thromboembolic acute myocardial infarction after aortic valve replacement using the Freestyle stentless aortic bioprosthesis with subcoronary valve replacement
    Watanabe, Yusuke
    Naganuma, Toru
    Kitanaka, Yosuke
    Nakamura, Sunao
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 55 (03) : 587 - 589
  • [29] STENTLESS PORCINE BIOPROSTHESIS FOR AORTIC-VALVE REPLACEMENT
    GOLDMAN, BS
    DAVID, TE
    DELRIZZO, DF
    SEVER, J
    BOS, J
    JOURNAL OF CARDIOVASCULAR SURGERY, 1994, 35 (06): : 105 - 110
  • [30] Impact of postoperative patient-prosthesis mismatch as a risk factor for early structural valve deterioration after aortic valve replacement with Trifecta bioprosthesis
    Wakami, Tatsuto
    Koizumi, Shigeki
    Koyama, Tadaaki
    JOURNAL OF CARDIOTHORACIC SURGERY, 2022, 17 (01)