Less invasive aortic valve replacement using the trifecta bioprosthesis

被引:2
|
作者
Agnino, Alfonso [1 ,2 ]
Graniero, Ascanio [1 ,2 ]
Gerometta, Piersilvio [1 ]
Giroletti, Laura [1 ,2 ]
Albano, Giovanni [3 ]
Roscitano, Claudio [3 ]
Anselmi, Amedeo [4 ]
机构
[1] Clin Humanitas Gavazzeni, Cardiovasc Dept, Bergamo, Italy
[2] Clin Humanitas Gavazzeni, Div Robot & Minimally Invas Cardiac Surg, Bergamo, Italy
[3] Clin Humanitas Gavazzeni, Div Cardiac Anesthesia, Bergamo, Italy
[4] Pontchaillou Univ Hosp, Div Thorac & Cardiovasc Surg, 2 Rue Henri le Guilloux, F-35000 Rennes, France
关键词
Aortic valve replacement; less invasive surgery; hemodynamics; outcomes; HEMODYNAMIC PERFORMANCE; PORCINE BIOPROSTHESIS; MIDTERM DURABILITY; MULTICENTER; MINISTERNOTOMY; MORTALITY;
D O I
10.1080/14017431.2022.2071460
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The safety and effectiveness of the Trifecta GT bioprosthesis (introduced in 2016) in less invasive aortic valve replacement are scarcely investigated. Our aim was to evaluate the immediate and initial follow-up results of this device in the context of less invasive surgery. We discuss patient-specific strategies for the selection of the surgical approach. Methods. A retrospective review of 133 patients undergoing AVR with the Trifecta GT through three less invasive accesses (UMS, Upper ministernotomy; RMS, Reversed ministernotomy; RAMT, Right anterior minithoracotomy) was performed. In-hospital, follow-up and hemodynamic performance (PPM, Patient-prosthesis mismatch) data were collected. Results. Among patients, 79% received UMS, 11% RMS and 10% RAMT. Selection of approach was based on preoperative anatomical analysis (CT-scan) and planned concomitant procedures. There was no operative mortality, no valve-related adverse events. There were 36 concomitant procedures. No significant intergroup differences occurred in cardiopulmonary bypass, aortic clamp, mechanical ventilation time, ICU stay and average bleeding. There were two cases of moderate PPM (1.5%) and no instances of severe PPM; there were no significant (>= 2/4) perivalvular leaks. Average mean gradient at discharge was 8 +/- 3 mmHg. At follow-up (average: 2.5 +/- 0.9 years, 100% complete, 315 patient years) there was no mortality and no valve-related adverse event. Hemodynamic performance was maintained at follow-up. Conclusions. The optimal device for less invasive AVR needs to be individualized, as well as the selection of the surgical approach. The use of the Trifecta GT bioprosthesis appears to be reproductible whatever less invasive approach is employed, with confirmed excellent hemodynamic performance.
引用
收藏
页码:79 / 84
页数:6
相关论文
共 50 条
  • [31] Impact of postoperative patient-prosthesis mismatch as a risk factor for early structural valve deterioration after aortic valve replacement with Trifecta bioprosthesis
    Tatsuto Wakami
    Shigeki Koizumi
    Tadaaki Koyama
    Journal of Cardiothoracic Surgery, 17
  • [32] Early Structural Valve Degeneration of Trifecta Bioprosthesis
    Fukuhara, Shinichi
    Shiomi, Suzuna
    Yang, Bo
    Kim, Karen
    Bolling, Steven F.
    Haft, Jonathan
    Tang, Paul
    Pagani, Francis
    Prager, Richard L.
    Chetcuti, Stanley
    Grossman, P. Michael
    Patel, Himanshu J.
    Deeb, G. Michael
    ANNALS OF THORACIC SURGERY, 2020, 109 (03): : 720 - 727
  • [33] AORTIC-VALVE REPLACEMENT WITH A STENTLESS PORCINE BIOPROSTHESIS
    GOLDMAN, BS
    DAVID, TE
    DELRIZZO, D
    YACOUB, M
    ALDRETE, V
    JOYNER, C
    MURPHY, P
    RAKOWSKI, H
    MCCALLUM, L
    CIRCULATION, 1994, 90 (04) : 310 - 310
  • [34] Percutaneous aortic valve replacement with the CoreValve bioprosthesis - Reply
    Marcheix, Bertrand
    Cartier, Raymond
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 135 (06): : 1408 - 1408
  • [35] eComment. Choice of bioprosthesis for aortic valve replacement
    Dimitrakakis, Georgios
    von Oppell, Ulrich O.
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2013, 16 (03) : 374 - 374
  • [36] Sutureless aortic valve replacement in stentless bioprosthesis failure
    Kim, Jae Hyun
    Kim, Jae-Bum
    Choi, Sae Young
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2015, 21 (06) : 801 - 802
  • [37] Minimally invasive aortic valve replacement with an expandable bioprosthesis after LVAD implantation as redo surgery
    Ozturk, Mahmut
    Risteski, Petar
    Doss, Mirko
    Popov, Aron-Frederik
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2022, 45 (08): : 685 - 687
  • [38] Percutaneous aortic valve replacement for severe aortic stenosis by CoreValve bioprosthesis
    Schuler, G.
    Linke, A.
    Moebius-Winkler, S.
    Mohr, F.
    Walther, T.
    Fassl, J.
    CIRCULATION, 2008, 118 (12) : E428 - E429
  • [39] Aortic valve replacement with a stentless bioprosthesis using the full-root technique
    Wendler, O
    Dzindzibadze, V
    Longer, F
    El Dsoki, S
    Schäfers, HJ
    THORACIC AND CARDIOVASCULAR SURGEON, 2001, 49 (06): : 361 - 364
  • [40] Early Failure of Trifecta Bioprosthesis in the Aortic Position
    Yoshida, Kazufumi
    Fukunaga, Naoto
    Sakon, Yoshito
    Koyama, Tadaaki