Less invasive aortic valve replacement using the trifecta bioprosthesis

被引:2
|
作者
Agnino, Alfonso [1 ,2 ]
Graniero, Ascanio [1 ,2 ]
Gerometta, Piersilvio [1 ]
Giroletti, Laura [1 ,2 ]
Albano, Giovanni [3 ]
Roscitano, Claudio [3 ]
Anselmi, Amedeo [4 ]
机构
[1] Clin Humanitas Gavazzeni, Cardiovasc Dept, Bergamo, Italy
[2] Clin Humanitas Gavazzeni, Div Robot & Minimally Invas Cardiac Surg, Bergamo, Italy
[3] Clin Humanitas Gavazzeni, Div Cardiac Anesthesia, Bergamo, Italy
[4] Pontchaillou Univ Hosp, Div Thorac & Cardiovasc Surg, 2 Rue Henri le Guilloux, F-35000 Rennes, France
关键词
Aortic valve replacement; less invasive surgery; hemodynamics; outcomes; HEMODYNAMIC PERFORMANCE; PORCINE BIOPROSTHESIS; MIDTERM DURABILITY; MULTICENTER; MINISTERNOTOMY; MORTALITY;
D O I
10.1080/14017431.2022.2071460
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The safety and effectiveness of the Trifecta GT bioprosthesis (introduced in 2016) in less invasive aortic valve replacement are scarcely investigated. Our aim was to evaluate the immediate and initial follow-up results of this device in the context of less invasive surgery. We discuss patient-specific strategies for the selection of the surgical approach. Methods. A retrospective review of 133 patients undergoing AVR with the Trifecta GT through three less invasive accesses (UMS, Upper ministernotomy; RMS, Reversed ministernotomy; RAMT, Right anterior minithoracotomy) was performed. In-hospital, follow-up and hemodynamic performance (PPM, Patient-prosthesis mismatch) data were collected. Results. Among patients, 79% received UMS, 11% RMS and 10% RAMT. Selection of approach was based on preoperative anatomical analysis (CT-scan) and planned concomitant procedures. There was no operative mortality, no valve-related adverse events. There were 36 concomitant procedures. No significant intergroup differences occurred in cardiopulmonary bypass, aortic clamp, mechanical ventilation time, ICU stay and average bleeding. There were two cases of moderate PPM (1.5%) and no instances of severe PPM; there were no significant (>= 2/4) perivalvular leaks. Average mean gradient at discharge was 8 +/- 3 mmHg. At follow-up (average: 2.5 +/- 0.9 years, 100% complete, 315 patient years) there was no mortality and no valve-related adverse event. Hemodynamic performance was maintained at follow-up. Conclusions. The optimal device for less invasive AVR needs to be individualized, as well as the selection of the surgical approach. The use of the Trifecta GT bioprosthesis appears to be reproductible whatever less invasive approach is employed, with confirmed excellent hemodynamic performance.
引用
收藏
页码:79 / 84
页数:6
相关论文
共 50 条
  • [41] Sutureless bioprosthesis for aortic valve replacement: Surgical and clinical outcomes
    Ferreira, Ricardo
    Rua, Nuno
    Sena, Andre
    Velho, Tiago R.
    Goncalves, Joao
    Junqueira, Nadia
    Almeida, Ana G.
    Nobre, Angelo
    Pinto, Fausto
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (12) : 4774 - 4782
  • [42] Less Invasive Aortic Valve Surgery
    Sampathkumar, Arkalgud
    ANNALS OF THORACIC SURGERY, 2022, 113 (06): : 2109 - 2109
  • [43] Less invasive aortic root replacement
    Westaby, S
    Katsumata, T
    Arifi, A
    ANNALS OF THORACIC SURGERY, 1998, 66 (04): : 1400 - 1401
  • [44] Sutureless bioprosthesis as an alternative to conventional aortic valve replacement surgery
    Rua, N.
    Ferreira, R.
    Sena, A.
    Nobre, A.
    EUROPEAN HEART JOURNAL, 2021, 42 : 1688 - 1688
  • [45] Valve replacement with a stentless bioprosthesis: Versatility of the porcine aortic root
    Westaby, S
    Jin, XY
    Katsumata, T
    Arifi, A
    Braidley, P
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 116 (03): : 477 - 484
  • [46] Incidence of Atrial Fibrillation After Aortic Valve Replacement With a Bioprosthesis
    Kiviniemi, Tuomas
    Malmberg, Markus
    Biancari, Fausto
    Hartikainen, Juha
    Ihlberg, Leo
    Yannopoulos, Fredrik
    Riekkinen, Teemu
    Airaksinen, Juhani
    Nieminen, Tuomo
    CIRCULATION, 2016, 134
  • [47] Repair of the bicuspid aortic valve: A viable alternative to replacement with a bioprosthesis
    Ashikhmina, Elena
    Sundt, Thoralf M., III
    Dearani, Joseph A.
    Connolly, Heidi M.
    Li, Zhuo
    Schaff, Hartzell V.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (06): : 1395 - 1401
  • [48] Solo Smart stentless bioprosthesis for redo aortic valve replacement
    Hamasaki, Azumi
    Uchida, Tetsuro
    Sadahiro, Mitsuaki
    JOURNAL OF CARDIAC SURGERY, 2020, 35 (02) : 485 - 487
  • [49] Aortic valve replacement with a stentless porcine bioprosthesis (TSPV(TM))
    Goldman, BS
    DelRizzo, DF
    Christakis, GT
    Sever, J
    Fremes, SE
    ISRAEL JOURNAL OF MEDICAL SCIENCES, 1996, 32 (10): : 846 - 848
  • [50] ISOLATED REPLACEMENT OF A PROSTHESIS OR A BIOPROSTHESIS IN THE AORTIC-VALVE POSITION
    ANTUNES, MJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (04): : 350 - 352