Impact of postoperative patient-prosthesis mismatch as a risk factor for early structural valve deterioration after aortic valve replacement with Trifecta bioprosthesis

被引:6
|
作者
Wakami, Tatsuto [1 ]
Koizumi, Shigeki [1 ]
Koyama, Tadaaki [1 ]
机构
[1] Kobe City Med Ctr Gen Hosp, Dept Cardiovasc Surg, Chuo Ku, 2-1-1 Minatojima Minamimachi, Kobe, Hyogo 650047, Japan
关键词
Trifecta; Aortic valve; Structural valve deterioration; DEGENERATION; DURABILITY; FAILURE; TEAR;
D O I
10.1186/s13019-022-01918-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Several studies have reported high rates of structural valve deterioration (SVD) in the Trifecta valves. Herein, we analyzed the midterm results of the Trifecta valve and risk factors for early SVD. Methods We retrospectively reviewed the records of 110 patients who had undergone Trifecta implantation between January 2012 and December 2017. Results We encountered seven cases of Trifecta valve failure. We performed a redo aortic valve replacement in five patients and a transcatheter aortic valve replacement in two patients. The SVD rate was 4.8% at 5 years and 6.6% at 7 years. The mean pressure gradient and peak velocity on the first postoperative echocardiogram in patients with SVD were higher than those in patients without SVD. The SVD rates with and without patient-prosthesis mismatch (PPM) were 2.8% and 12.6% at 5 years and 2.8% and 20.0% at 7 years. PPM is a risk factor for SVD. Noncoronary cusp tears were observed in all patients who had undergone redo surgery. Conclusions The most common cause of SVD was noncoronary cusp tear. Patients with PPM are at high risk of developing SVD.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Impact of postoperative patient-prosthesis mismatch as a risk factor for early structural valve deterioration after aortic valve replacement with Trifecta bioprosthesis
    Tatsuto Wakami
    Shigeki Koizumi
    Tadaaki Koyama
    Journal of Cardiothoracic Surgery, 17
  • [2] Patient-prosthesis mismatch after aortic valve replacement in the elderly
    Ryomoto M.
    Mitsuno M.
    Yamamura M.
    Tanaka H.
    Kobayashi Y.
    Fukui S.
    Tsujiya N.
    Kajiyama T.
    Miyamoto Y.
    General Thoracic and Cardiovascular Surgery, 2008, 56 (7) : 330 - 334
  • [3] PATIENT-PROSTHESIS MISMATCH ON OCTOGENARIANS AFTER AORTIC VALVE REPLACEMENT: IMPACT ON EARLY AND LATE MORTALITY
    Buu-Khanh Lam
    Elmestekawy, Elsayed
    Lapierre, Harry
    Tran, Diem T.
    Ruel, Marc
    Mesana, Thierry G.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E1364 - E1364
  • [4] Impact of patient-prosthesis mismatch and aortic valve design on coronary flow reserve after aortic valve replacement
    Bakhtiary, Farhad
    Schiemann, Mirko
    Dzemali, Omer
    Dogan, Selami
    Schaechinger, Volker
    Ackermann, Hans
    Moritz, Anton
    Kleine, Peter
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (07) : 790 - 796
  • [5] Patient-prosthesis mismatch following aortic valve replacement
    Bilkhu, Rajdeep
    Jahangiri, Marjan
    Otto, Catherine M.
    HEART, 2019, 105 : S28 - S33
  • [6] Clinical Impact of Patient-Prosthesis Mismatch After Aortic Valve Replacement With a Mechanical or Biological Prosthesis
    Matkovic, Milos
    Aleksic, Nemanja
    Bilbija, Ilija
    Antic, Ana
    Lazovic, Jelena Milin
    Cubrilo, Marko
    Milojevic, Aleksandar
    Zivkovic, Igor
    Putnik, Svetozar
    TEXAS HEART INSTITUTE JOURNAL, 2023, 50 (05)
  • [7] Early outcomes of patient-prosthesis mismatch following aortic valve replacement
    Aitaliyev, Serik
    Rumbinaite, Egle
    Melinyte-Ankudavice, Karolina
    Nekrosius, Rokas
    Keturakis, Vytenis
    Benetis, Rimantas
    PERFUSION-UK, 2022, 37 (07): : 692 - 699
  • [8] Patient-prosthesis mismatch in patients with aortic valve replacement
    Kaminishi Y.
    Misawa Y.
    Kobayashi J.
    Konishi H.
    Miyata H.
    Motomura N.
    Takamoto S.-I.
    General Thoracic and Cardiovascular Surgery, 2013, 61 (5) : 274 - 279
  • [9] Structural valve deterioration after aortic valve replacement with the Trifecta valve
    Werner, Paul
    Gritsch, Jasmin
    Scherzer, Sabine
    Gross, Christoph
    Russo, Marco
    Coti, Iuliana
    Kocher, Alfred
    Laufer, Guenther
    Andreas, Martin
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2021, 32 (01) : 39 - 46
  • [10] Patient-prosthesis mismatch after minimally invasive aortic valve replacement
    Filip, Grzegorz
    Litwinowicz, Radoslaw
    Kapelak, Boguslaw
    Bryndza, Magdalena
    Bartus, Magdalena
    Konstanty-Kalandyk, Janusz
    Ceranowicz, Piotr
    Brzezinski, Maciej
    Gafoor, Sameer
    Bartus, Krzysztof
    KARDIOLOGIA POLSKA, 2018, 76 (05) : 908 - 910