Impact of postoperative patient-prosthesis mismatch as a risk factor for early structural valve deterioration after aortic valve replacement with Trifecta bioprosthesis

被引:6
|
作者
Wakami, Tatsuto [1 ]
Koizumi, Shigeki [1 ]
Koyama, Tadaaki [1 ]
机构
[1] Kobe City Med Ctr Gen Hosp, Dept Cardiovasc Surg, Chuo Ku, 2-1-1 Minatojima Minamimachi, Kobe, Hyogo 650047, Japan
关键词
Trifecta; Aortic valve; Structural valve deterioration; DEGENERATION; DURABILITY; FAILURE; TEAR;
D O I
10.1186/s13019-022-01918-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Several studies have reported high rates of structural valve deterioration (SVD) in the Trifecta valves. Herein, we analyzed the midterm results of the Trifecta valve and risk factors for early SVD. Methods We retrospectively reviewed the records of 110 patients who had undergone Trifecta implantation between January 2012 and December 2017. Results We encountered seven cases of Trifecta valve failure. We performed a redo aortic valve replacement in five patients and a transcatheter aortic valve replacement in two patients. The SVD rate was 4.8% at 5 years and 6.6% at 7 years. The mean pressure gradient and peak velocity on the first postoperative echocardiogram in patients with SVD were higher than those in patients without SVD. The SVD rates with and without patient-prosthesis mismatch (PPM) were 2.8% and 12.6% at 5 years and 2.8% and 20.0% at 7 years. PPM is a risk factor for SVD. Noncoronary cusp tears were observed in all patients who had undergone redo surgery. Conclusions The most common cause of SVD was noncoronary cusp tear. Patients with PPM are at high risk of developing SVD.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Patient-prosthesis mismatch after small-size stentless aortic valve replacement
    Gelsomino, S
    Morocutti, G
    Masullo, G
    Da Col, P
    Frassani, R
    Spedicato, L
    Livi, U
    JOURNAL OF CARDIAC SURGERY, 2004, 19 (02) : 91 - 97
  • [42] SUTURELESS AORTIC VALVE REPLACEMENT TO PREVENT PATIENT-PROSTHESIS MISMATCH IN THE ERA OF VALVE-IN-VALVE IMPLANTATION
    Santarpino, Giuseppe
    Pfeiffer, Steffen
    Fischlein, Theodor
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 144 (01): : 279 - 280
  • [43] Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement with a stentless bioprosthesis
    Lopez, Stéphane
    Mathieu, Patrick
    Voisine, Pierre
    Dagenais, François
    Dumesnil, Jean-Gaston
    Baillot, Richard
    Métras, Jacques
    Doyle, Daniel
    Pibarot, Philippe
    CIRCULATION, 2006, 114 (18) : 793 - 793
  • [44] Impact of patient-prosthesis mismatch after transcatheter aortic valve-in-valve implantation in degenerated bioprostheses
    Seiffert, Moritz
    Conradi, Lenard
    Baldus, Stephan
    Knap, Malgorzata
    Schirmer, Johannes
    Franzen, Olaf
    Koschyk, Dietmar
    Meinertz, Thomas
    Reichenspurner, Hermann
    Treede, Hendrik
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 143 (03): : 617 - 624
  • [45] Impact of Left Ventricular Function on Patient-Prosthesis Mismatch Post Transcatheter Aortic Valve Replacement
    Chen, Kai
    James, Taylor Michiko
    Rothenberg, Mark
    Kapilla, Arvind
    Faber, Cristiano
    Nores, Marcos A.
    Stamou, Sotiris C.
    JOURNAL OF CARDIAC FAILURE, 2019, 25 (08) : S41 - S41
  • [46] Patient-prosthesis mismatch after mitral valve replacement: Myth or reality?
    Totaro, Pasquale
    Argano, Vincenzo
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 134 (03): : 697 - 701
  • [47] Patient-prosthesis mismatch after mitral valve replacement: Is it a fact or myth?
    Mattr, Rehab M.
    Abdelwahab, Amr A.
    Elnasr, Mohamed A.
    Wahby, Ehab
    Taha, Abdelhady
    EGYPTIAN JOURNAL OF SURGERY, 2022, 41 (02): : 676 - 683
  • [48] The impact of patient-prosthesis mismatch on late outcomes after mitral valve replacement - Discussion
    Crawford, F.
    Martinez-Sanz, R.
    Lam
    Jamieson, E.
    Totaro, Pasquale
    He, Guo-Wei
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 133 (06): : 1472 - 1473
  • [49] Patient-prosthesis mismatch after transapical aortic valve implantation: Incidence and impact on survival
    Kukucka, Marian
    Pasic, Miralem
    Dreysse, Stephan
    Mladenow, Alexander
    Habazettl, Helmut
    Hetzer, Roland
    Unbehaun, Axel
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (02): : 391 - 397
  • [50] Patient-prosthesis mismatch does not affect survival following aortic valve replacement
    Howell, Neil J.
    Keogh, Bruce E.
    Barnet, Vivien
    Bonser, Robert S.
    Graham, Timothy R.
    Rooney, Stephen J.
    Wilson, Ian C.
    Pagano, Domenico
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2006, 30 (01) : 10 - 14