Impact of patient-prosthesis mismatch after transcatheter aortic valve-in-valve implantation in degenerated bioprostheses

被引:49
|
作者
Seiffert, Moritz [1 ]
Conradi, Lenard [1 ]
Baldus, Stephan [2 ]
Knap, Malgorzata [2 ]
Schirmer, Johannes [1 ]
Franzen, Olaf [2 ]
Koschyk, Dietmar [2 ]
Meinertz, Thomas [2 ]
Reichenspurner, Hermann [1 ]
Treede, Hendrik [1 ]
机构
[1] Univ Heart Ctr Hamburg, Dept Cardiovasc Surg, D-20246 Hamburg, Germany
[2] Univ Heart Ctr Hamburg, Dept Gen & Intervent Cardiol, D-20246 Hamburg, Germany
来源
关键词
LONG-TERM SURVIVAL;
D O I
10.1016/j.jtcvs.2011.11.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Transcatheter valve-in-valve implantation is evolving as an alternative to reoperative valve replacement in high-risk patients with degenerated bioprostheses. Nevertheless, hemodynamic performance is limited by the previously implanted xenograft. We report our experience with patient-prosthesis mismatch (PPM) after valve-in-valve implantation in the aortic position. Methods: Eleven patients (aged 79.3 +/- 6.1 years) received transapical implantation of a balloon-expandable pericardial heart valve into a degenerated bioprosthesis (size, 23.9 +/- 1.6 mm; range, 21-27 mm) in the aortic position. All patients were considered high risk for surgical valve replacement (logistic European System for Cardiac Operative Risk Evaluation, 31.8% +/- 24.1%). Severe PPM was defined as an indexed effective orifice area less than 0.65 cm(2)/m(2), determined by discharge echocardiography. Results: Severe PPM was evident in 5 patients (group 1) and absent in 6 patients (group 2). Mean transvalvular gradients decreased from 29.2 +/- 15.4 mm Hg before implantation to 21.2 +/- 9.7 mm Hg at discharge (group 1) and from 28.2 +/- 9.0 mm Hg before implantation to 15.2 +/- 6.5 mm Hg at discharge (group 2). Indexed effective orifice area increased from 0.5 +/- 0.1 cm(2)/m(2) to 0.6 +/- 0.1 cm(2)/m(2) and from 0.6 +/- 0.3 cm(2)/m(2) to 0.8 +/- 0.3 cm(2)/m(2). Aortic regurgitation decreased from grade 2.0 +/- 1.1 to 0.4 +/- 0.5 overall. No differences in New York Heart Association class improvement or survival during follow-up were observed. One patient required reoperation for symptomatic PPM 426 days after implantation. Conclusions: Valve-in-valve implantation can be performed in high-risk surgical patients to avoid reoperation. However, PPM frequently occurs, making adequate patient selection crucial. Small bioprostheses (<23 mm) should be avoided. Implantation into 23-mm xenografts can be recommended only for patients with a body surface area less than 1.8 m(2). Larger prostheses seem to carry a lower risk for PPM. Although no delay in clinical improvement was seen at short-term, 1 PPM-related surgical intervention raises concern regarding long-term performance. (J Thorac Cardiovasc Surg 2012;143:617-24)
引用
收藏
页码:617 / 624
页数:8
相关论文
共 50 条
  • [1] Incidence and impact of patient-prosthesis mismatch after transcatheter aortic valve implantation
    Bleiziffer, S.
    Ruge, H.
    Hutter, A.
    Opitz, A.
    Hettich, I.
    Elhmidi, Y.
    Mazzitelli, D.
    Bauernschmitt, R.
    Lange, R.
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 : 665 - 665
  • [2] Incidence And Impact Of Patient-Prosthesis Mismatch After Transcatheter Aortic Valve Implantation
    Bleiziffer, Sabine
    Ruge, Hendrik
    Hutter, Andrea
    Opitz, Anke
    Hettich, Ina
    Mazzitelli, Domenico
    Bauernschmitt, Robert
    Lange, Ruediger
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 31D - 31D
  • [3] Transcatheter valve-in-valve implantation for degenerated surgical bioprostheses
    Murdoch, Dale J.
    Webb, John G.
    [J]. JOURNAL OF THORACIC DISEASE, 2018, 10 : S3573 - S3577
  • [4] Transcatheter Aortic Valve Implantation for Treatment of Patients With Degenerated Aortic Bioprostheses - Valve-in-Valve Technique
    Gotzmann, Michael
    Muegge, Andreas
    Bojara, Waldemar
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (07) : 1000 - 1006
  • [5] SUTURELESS AORTIC VALVE REPLACEMENT TO PREVENT PATIENT-PROSTHESIS MISMATCH IN THE ERA OF VALVE-IN-VALVE IMPLANTATION
    Santarpino, Giuseppe
    Pfeiffer, Steffen
    Fischlein, Theodor
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 144 (01): : 279 - 280
  • [6] Patient-prosthesis mismatch after transapical aortic valve implantation
    Kukucka, Marian
    Pasic, Miralem
    Dreysse, Stephan
    Buz, Semih
    Drews, Thorsten
    Mladenow, Alexander
    Habazettl, Helmut
    Kuppe, Hermann
    Unbehaun, Axel
    Hetzer, Roland
    [J]. ANNALS OF CARDIOTHORACIC SURGERY, 2012, 1 (02) : 172 - 175
  • [7] Valve-in-Valve Transcatheter Aortic Valve Implantation: The New Playground for Prosthesis-Patient Mismatch
    Faerber, Gloria
    Schleger, Simone
    Diab, Mahmoud
    Breuer, Martin
    Figulla, Hans R.
    Eichinger, Walter B.
    Doenst, Torsten
    [J]. JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2014, 27 (03) : 287 - 292
  • [8] Simultaneous Transcatheter Aortic and Mitral Valve-in-Valve Implantation in a Patient with Degenerated Bioprostheses and High Surgical Risk
    Seiffert, M.
    Baldus, S.
    Conradi, L.
    Koschyk, D.
    Schirmer, J.
    Meinertz, T.
    Reichenspurner, H.
    Treede, H.
    [J]. THORACIC AND CARDIOVASCULAR SURGEON, 2011, 59 (08): : 490 - 492
  • [9] Transcatheter Mitral Valve-in-Valve Implantation in Patients With Degenerated Bioprostheses
    Seiffert, Moritz
    Conradi, Lenard
    Baldus, Stephan
    Schirmer, Johannes
    Knap, Malgorzata
    Blankenberg, Stefan
    Reichenspurner, Hermann
    Treede, Hendrik
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (03) : 341 - 349
  • [10] Compassionate valve-in-valve transcatheter aortic valve implantation in high risk patients with degenerated bioprostheses
    Husser, O.
    Schopka, S.
    Holzamer, A.
    Riegger, G. A. J.
    Schmid, C.
    Hengstenberg, C.
    Hilker, M.
    [J]. EUROPEAN HEART JOURNAL, 2012, 33 : 580 - 581