摘要
Transcatheter aortic valve implantation (TAVI) has become an established procedure for patients with aortic valve stenosis and significant comorbidities. One option offered by this technique is the implantation of a transcatheter valve inside a surgically implanted bioprosthesis. Many reports address the feasibility but also the pitfalls of these valve-in-valve (VIV) procedures. Review articles provide tables listing which valve sizes are appropriate based on the size of the initially implanted bioprosthesis. However, we previously argued that the hemodynamic performance of a prosthetic tissue valve is in large part a result of the dimensions of the bioprosthesis in relation to the patient's aortic outflow dimensions. Thus, the decision if a VIV TAVI procedure is likely to be associated with a favorable hemodynamic result cannot safely be made by looking at premade sizing tables that do not include patient dimensions and do not inquire about the primary cause for bioprosthetic valve stenosis. Prosthesis-patient mismatch (PPM) may therefore be more frequent than expected after conventional aortic valve replacement. Importantly, it may be masked by a potentially flawed method assessing its relevance. Such PPM may therefore impact significantly on hemodynamic outcome after VIV TAVI. Fifteen percent of currently published VIV procedures show only a minimal reduction of pressure gradients. We will address potential pitfalls in the current determination of PPM, outline the missing links for reliable determination of PPM, and present a simplified algorithm to guide decision making for VIV TAVI.
引用
收藏
页码:287 / 292
页数:6
相关论文
共 50 条
  • [1] Prosthesis-Patient Mismatch after Aortic Valve-In-Valve Implantation: Insights from the Global Valve-in-Valve Registry
    Bleiziffer, Sabine
    John, Webb
    Lange, Rudiger
    Napodano, Massimo
    Kodali, Susheel
    Hildick-Smith, David
    Himbert, Dominique
    Schaefer, Ulrich
    Rodes-Cabau, Josep
    Treede, Hendrik
    Barbanti, Marco
    Brecker, Stephen
    Latib, Azeem
    Laborde, Jean-Claude
    Kornowski, Ran
    Dvir, Danny
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : B38 - B38
  • [2] Prosthesis-patient mismatch after transcatheter aortic valve implantation
    Leone, Pier Pasquale
    Pagnesi, Matteo
    Regazzoli, Damiano
    Latib, Azeem
    [J]. GIORNALE ITALIANO DI CARDIOLOGIA, 2020, 21 (11) : 26S - 34S
  • [3] Prosthesis-patient mismatch after transcatheter aortic valve implantation
    Miyasaka, Masaki
    [J]. CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2022, 37 (04) : 615 - 625
  • [4] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation
    Takagi, Hisato
    Umemoto, Takuya
    [J]. ANNALS OF THORACIC SURGERY, 2016, 101 (03): : 872 - 880
  • [5] Prosthesis-Patient Mismatch after Aortic Valve-In-Valve Implantation: Insights from the Valve-in-Valve International Data (VIVID) Registry
    Bleiziffer, Sabine
    Webb, John
    Kornowski, Ran
    Holzhey, David M.
    Santos, Matheus S.
    George, Isaac
    Sinning, Jan-Malte
    Napodano, Massimo
    Nombela-Franco, Luis
    Guerrero, Mayra
    Nissen, Henrik
    Rudolph, Tanja
    Brecker, Stephen
    Shah, Ashish
    Petursson, Petur
    Cerillo, Alfredo Giuseppe
    Chandran, Sujay
    Moat, Neil
    Gaia, Diego F.
    Park, Seung-Jung
    Bonaros, Nikolaos
    Bekeredjian, Raffi
    Lange, Ruediger
    Dvir, Danny
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B62 - B62
  • [6] Incidence and Impact of Prosthesis-Patient Mismatch after Transcatheter Aortic Valve Implantation
    Bleiziffer, Sabine
    Hettich, Ina
    Hutter, Andrea
    Wagner, Anke
    Deutsch, Marcus-Andre
    Piazza, Nicolo
    Lange, Ruediger
    [J]. JOURNAL OF HEART VALVE DISEASE, 2013, 22 (03): : 309 - 316
  • [7] Incidence and impact of prosthesis-patient mismatch following transcatheter aortic valve implantation
    Seoudy, Hatim
    Guessefeld, Nathalie
    Frank, Johanne
    Freitag-Wolf, Sandra
    Lutter, Georg
    Eden, Matthias
    Rangrez, AshrafYusuf
    Kuhn, Christian
    Frey, Norbert
    Frank, Derk
    [J]. CLINICAL RESEARCH IN CARDIOLOGY, 2019, 108 (06) : 660 - 668
  • [8] Incidence of Prosthesis-Patient Mismatch in Valve-in-Valve with a Supra-Annular Valve
    Alwan, Louhai
    Ruge, Hendrik
    Krane, Markus
    Prinzing, Anatol
    Noebauer, Christian
    Lange, Rudiger
    Erlebach, Magdalena
    [J]. THORACIC AND CARDIOVASCULAR SURGEON, 2023, 71 (08): : 632 - 640
  • [9] Impact of patient-prosthesis mismatch after transcatheter aortic valve-in-valve implantation in degenerated bioprostheses
    Seiffert, Moritz
    Conradi, Lenard
    Baldus, Stephan
    Knap, Malgorzata
    Schirmer, Johannes
    Franzen, Olaf
    Koschyk, Dietmar
    Meinertz, Thomas
    Reichenspurner, Hermann
    Treede, Hendrik
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 143 (03): : 617 - 624
  • [10] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Herrmann, Howard C.