Patient-prosthesis mismatch does not affect survival following aortic valve replacement

被引:70
|
作者
Howell, Neil J. [1 ]
Keogh, Bruce E. [1 ]
Barnet, Vivien [1 ]
Bonser, Robert S. [1 ]
Graham, Timothy R. [1 ]
Rooney, Stephen J. [1 ]
Wilson, Ian C. [1 ]
Pagano, Domenico [1 ]
机构
[1] Univ Hosp NHS Fdn Trust, Dept Cardiothorac Surg, Birmingham, W Midlands, England
关键词
aortic valve disease; aortic valve replacement;
D O I
10.1016/j.ejcts.2006.03.046
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Patient-prosthesis mismatch (PPM) has been reported to increase perioperative mortality and reduce postoperative survival in patients undergoing aortic valve replacement (AVR). We analysed the effect of PPM at values predicting severe mismatch on survival following AVR in our unit. Methods: Prospectively collected data on 1481 consecutive patients who had undergone AVR with or without coronary artery revascularisation between 1997 and 2005 were analysed. Projected in vitro valve effective orifice area (EOA) and geometric prosthesis internal orifice area (GOA) were evaluated and values were indexed to body surface area (cm(2) m(-2)). PPM was defined as EOAi < 0.6 and/or GOAi < 1.1. Long-term survival data were obtained from the National Institute of Statistics. Results: One thousand four hundred and eighteen patients were identified. 67/1418 (4.7%) patients had GOAi < 1.1; 122/1418 (8.6%) had EOAi < 0.6 and 38 (2.6%) patients exhibited both forms of mismatch. One thousand two hundred and sixty-seven patients (89%) demonstrated no mismatch (reference group). There were 75 in-hospital deaths (overall mortality 5.3%) with no significant difference between the mismatch and the reference groups. Survival data were available for up to 8 years (median 36 months, IQR 6-60 months). There were 160 late deaths (13/143 PPM group vs 147/1198 reference group). The 5-year survival estimate was similar for both groups (83% PPM group; 81% reference group; p = 0.47). Cox-hazard analysis identified advanced age as the only predictor of reduced survival (age > 80, RR 2.13, 95% CI 1.38-4.586, p = 0.004). Conclusions: Severe patient-prosthesis mismatch was predicted in 4-10% of patients undergoing AVR but this did not affect in-hospital mortality or mid-term survival. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:10 / 14
页数:5
相关论文
共 50 条
  • [1] Patient-prosthesis mismatch does not affect survival following aortic valve replacement - Appendix A. Conference discussion
    Thubrikar, M.
    Howell
    Wahba, A.
    Tsai, J.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2006, 30 (01) : 14 - 14
  • [2] Patient-prosthesis mismatch following aortic valve replacement
    Bilkhu, Rajdeep
    Jahangiri, Marjan
    Otto, Catherine M.
    HEART, 2019, 105 : S28 - S33
  • [3] Patient-Prosthesis Mismatch in Patients With Aortic Stenosis Undergoing Isolated Aortic Valve Replacement Does Not Affect Survival
    Howell, Neil J.
    Keogh, Bruce E.
    Ray, Daniel
    Bonser, Robert S.
    Graham, Tim R.
    Mascaro, Jorge
    Rooney, Stephen J.
    Wilson, Ian C.
    Pagano, Domenico
    ANNALS OF THORACIC SURGERY, 2010, 89 (01): : 60 - 64
  • [4] Does patient-prosthesis mismatch after aortic valve replacement affect survival and quality of life in elderly patients?
    Sportelli, Elena
    Regesta, Tommaso
    Salsano, Antonio
    Ghione, Paola
    Brega, Carlotta
    Bezante, Gian Paolo
    Passerone, Giancarlo
    Santini, Francesco
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2016, 17 (02) : 137 - 143
  • [5] Patient-prosthesis mismatch affects survival after aortic valve replacement
    Rao, V
    Jamieson, WRE
    Ivanov, J
    Armstrong, S
    David, TE
    CIRCULATION, 1999, 100 (18) : 461 - 461
  • [6] Early outcomes of patient-prosthesis mismatch following aortic valve replacement
    Aitaliyev, Serik
    Rumbinaite, Egle
    Melinyte-Ankudavice, Karolina
    Nekrosius, Rokas
    Keturakis, Vytenis
    Benetis, Rimantas
    PERFUSION-UK, 2022, 37 (07): : 692 - 699
  • [7] Measured or Predicted Patient-Prosthesis Mismatch Following Aortic Valve Replacement
    Abushouk, Abdelrahman I.
    Aglan, Amro
    Mahana, Ingy A.
    Puri, Rishi
    Krishnaswamy, Amar
    Reed, Grant W.
    Yun, James
    Kapadia, Samir R.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (11) : 1428 - 1430
  • [8] Patient-prosthesis mismatch in patients with aortic valve replacement
    Kaminishi Y.
    Misawa Y.
    Kobayashi J.
    Konishi H.
    Miyata H.
    Motomura N.
    Takamoto S.-I.
    General Thoracic and Cardiovascular Surgery, 2013, 61 (5) : 274 - 279
  • [9] Patient-prosthesis mismatch in aortic valve replacement:: really tolerable?
    Fuster, RG
    Argudo, JAM
    Albarova, OG
    Sos, FH
    López, SC
    Codoñer, MB
    Miñano, JAB
    Albarran, IR
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 27 (03) : 441 - 449
  • [10] Does prosthesis–patient mismatch affect outcome of aortic valve replacement?
    Rebecca Ireland
    Nature Clinical Practice Cardiovascular Medicine, 2006, 3 (5): : 236 - 236