Impact of postoperative patient-prosthesis mismatch as a risk factor for early structural valve deterioration after aortic valve replacement with Trifecta bioprosthesis

被引:6
|
作者
Wakami, Tatsuto [1 ]
Koizumi, Shigeki [1 ]
Koyama, Tadaaki [1 ]
机构
[1] Kobe City Med Ctr Gen Hosp, Dept Cardiovasc Surg, Chuo Ku, 2-1-1 Minatojima Minamimachi, Kobe, Hyogo 650047, Japan
关键词
Trifecta; Aortic valve; Structural valve deterioration; DEGENERATION; DURABILITY; FAILURE; TEAR;
D O I
10.1186/s13019-022-01918-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Several studies have reported high rates of structural valve deterioration (SVD) in the Trifecta valves. Herein, we analyzed the midterm results of the Trifecta valve and risk factors for early SVD. Methods We retrospectively reviewed the records of 110 patients who had undergone Trifecta implantation between January 2012 and December 2017. Results We encountered seven cases of Trifecta valve failure. We performed a redo aortic valve replacement in five patients and a transcatheter aortic valve replacement in two patients. The SVD rate was 4.8% at 5 years and 6.6% at 7 years. The mean pressure gradient and peak velocity on the first postoperative echocardiogram in patients with SVD were higher than those in patients without SVD. The SVD rates with and without patient-prosthesis mismatch (PPM) were 2.8% and 12.6% at 5 years and 2.8% and 20.0% at 7 years. PPM is a risk factor for SVD. Noncoronary cusp tears were observed in all patients who had undergone redo surgery. Conclusions The most common cause of SVD was noncoronary cusp tear. Patients with PPM are at high risk of developing SVD.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Subvalvular stenosis at repeat aortic valve replacement for patient-prosthesis mismatch
    Girard, SE
    Miller, FA
    Edwards, WD
    Tazelaar, HD
    Mahoney, DW
    Malouf, YF
    Tajik, AJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 534A - 534A
  • [32] Patient-Prosthesis Mismatch After Surgical Aortic Valve Replacement: Analysis of the PARTNER Trials
    Thourani, Vinod H.
    Abbas, Amr E.
    Ternacle, Julien
    Hahn, Rebecca T.
    Makkar, Raj
    Kodali, Susheel K.
    George, Isaac
    Kapadia, Samir
    Svensson, Lars G.
    Szeto, Wilson Y.
    Herrmann, Howard C.
    Ailawadi, Gorav
    Leipsic, Jonathon
    Blanke, Philipp
    Webb, John
    Jaber, Wael A.
    Russo, Mark
    Malaisrie, S. Chris
    Yadav, Pradeep
    Clavel, Marie-Annick
    Khalique, Omar K.
    Weissman, Neil J.
    Douglas, Pamela
    Bax, Jeroen
    Dahou, Abdellaziz
    Xu, Ke
    Bapat, Vinayak
    Alu, Maria C.
    Leon, Martin B.
    Mack, Michael J.
    Pibarot, Philippe
    ANNALS OF THORACIC SURGERY, 2024, 117 (06): : 1164 - 1171
  • [33] Surgical versus transcatheter aortic valve replacement: Impact of patient-prosthesis mismatch on outcomes
    Alnajar, Ahmed
    Hamad, Naser
    Azhar, Muhammad Z.
    Mousa, Yaseen
    Arora, Yingyot
    Lamelas, Joseph
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (12) : 5388 - 5394
  • [34] Patient-Prosthesis Mismatch and Reduction in Left Ventricular Mass After Aortic Valve Replacement
    Kandler, Kristian
    Moller, Christian H.
    Hassager, Christian
    Olsen, Peter S.
    Lilleor, Nikolaj
    Steinbruchel, Daniel A.
    ANNALS OF THORACIC SURGERY, 2013, 96 (01): : 66 - 71
  • [35] The influence of patient-prosthesis mismatch on in-hospital complications and early mortality after aortic valve replacement
    Nozohoor, Shahab
    Nilsson, Johan
    Luhrs, Carsten
    Roijer, Anders
    Sjogren, Johan
    JOURNAL OF HEART VALVE DISEASE, 2007, 16 (05): : 475 - 482
  • [36] Measured or Predicted Patient-Prosthesis Mismatch Following Aortic Valve Replacement
    Abushouk, Abdelrahman I.
    Aglan, Amro
    Mahana, Ingy A.
    Puri, Rishi
    Krishnaswamy, Amar
    Reed, Grant W.
    Yun, James
    Kapadia, Samir R.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (11) : 1428 - 1430
  • [37] Patient-Prosthesis Mismatch and Strategies to Prevent It During Aortic Valve Replacement
    Apostolakis, Efstratios
    Baikoussis, Nikolaos G.
    Papakonstantinou, Nikolaos A.
    Goudevenos, John
    HELLENIC JOURNAL OF CARDIOLOGY, 2011, 52 (01) : 41 - 51
  • [38] THE IMPACT OF PATIENT-PROSTHESIS MISMATCH ON LEFT VENTRICULAR MYOCARDIAL MECHANICS AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT
    Poulin, F.
    Horlick, E. M.
    Woo, A.
    Thavendiranathan, P.
    CANADIAN JOURNAL OF CARDIOLOGY, 2013, 29 (10) : S159 - S160
  • [39] Impact of Patient-Prosthesis Mismatch on Short-Term Outcome after Aortic Valve Replacement Surgery
    Castro, M. F.
    Benzadon, M.
    Thierer, J.
    Piccinini, F.
    Vrancic, M.
    Vacarino, G.
    Navia, D.
    CARDIOLOGY, 2010, 115 (04) : 256 - 256
  • [40] Effect of Patient-Prosthesis Mismatch on the Hemodynamics and Quality of Life after Aortic Valve Replacement
    Fukunaga, S.
    Ueda, T.
    Mori, R.
    Akasu, K.
    Kosuga, T.
    Tomoeda, H.
    Chihara, S.
    Arinaga, K.
    Aoyagi, S.
    CARDIOLOGY, 2010, 115 (04) : 269 - 269