Midterm results after aortic valve replacement with a stentless bioprosthesis aortic valve

被引:6
|
作者
Martinovic, I
Everlien, M
Farah, I
Wittlinger, T
Knez, I
Greve, H
Vogt, P
机构
[1] Klinikum Krefeld, Dept Cardiothorac Surg, Krefeld, Germany
[2] Univ Giessen, Dept Cardiovasc Surg, Giessen, Germany
来源
ANNALS OF THORACIC SURGERY | 2005年 / 80卷 / 01期
关键词
D O I
10.1016/j.athoracsur.2005.01.027
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. It is suggested that a simplified implant model Cryolife-O'Brien (CryoLife International, Kennesaw, GA) offers less satisfactory outcome compared with standard stentless models. This study was conducted to prospectively evaluate the midterm results after aortic valve replacement with the Cryolife-O'Brien stentless bioprosthesis. Methods. In 1996, a prospective clinical trial using different stentless valves was initiated. From September 1996 through September 2002, 156 consecutive patients with a mean age of 74.5 years underwent aortic valve replacement with the Cryolife-O'Brien porcine stentless bioprosthesis. The predominant aortic valve lesion was stenosis in 128 and insufficiency in 28 cases. Patients have been followed from 2 to 72 months (mean, 42 months). Echocardiography was performed by one echocardiographer preoperatively, intraoperatively, postoperatively at discharge, 2 to 6 months later, and annually thereafter. Results. Sixty percent of patients received a valve 25 mm. in diameter or larger; 39% had concomittant coronary bypass grafting. The 30-day operative mortality rate was 6.4%. Ten late nonvalve-related deaths have occurred. Severe aortic insufficiency caused by oversizing leads to early reoperation in 3 patients. The peak and mean systolic gradients decreased significantly during the first 12 months after implantation, p < 0.001, and the effective valve areas increased significantly during this time interval p < 0.001. At 5 years, ten patients have moderate aortic insufficiency. The actuarial survival at 5 years was 88 +/- 3%. The rate for freedom from endocarditis was 100% and for freedom from thromboembolic events was 94%. Conclusions. Midterm results after aortic valve replacement with the Cryolife-O'Brien stentless bioprosthesis are encouraging. Good hemodynamics have been coupled with low rate of valve-related complications, thus representing a very good alternative to conventional stented bioprostheses. (c) 2005 by The Society of Thoracic Surgeons.
引用
收藏
页码:198 / 203
页数:6
相关论文
共 50 条
  • [1] AORTIC-VALVE REPLACEMENT WITH STENTLESS PORCINE AORTIC BIOPROSTHESIS
    DAVID, TE
    POLLICK, C
    BOS, J
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1990, 99 (01): : 113 - 118
  • [2] AORTIC-VALVE REPLACEMENT WITH A STENTLESS PORCINE BIOPROSTHESIS
    GOLDMAN, BS
    DAVID, TE
    DELRIZZO, D
    YACOUB, M
    ALDRETE, V
    JOYNER, C
    MURPHY, P
    RAKOWSKI, H
    MCCALLUM, L
    [J]. CIRCULATION, 1994, 90 (04) : 310 - 310
  • [3] STENTLESS PORCINE BIOPROSTHESIS FOR AORTIC-VALVE REPLACEMENT
    GOLDMAN, BS
    DAVID, TE
    DELRIZZO, DF
    SEVER, J
    BOS, J
    [J]. JOURNAL OF CARDIOVASCULAR SURGERY, 1994, 35 (06): : 105 - 110
  • [4] Eight-year results after aortic valve replacement with the freestyle stentless bioprosthesis
    Bach, DS
    Kon, ND
    Dumesnil, JG
    Sintek, CF
    Doty, DB
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 127 (06): : 1657 - 1663
  • [5] Sutureless aortic valve replacement in stentless bioprosthesis failure
    Kim, Jae Hyun
    Kim, Jae-Bum
    Choi, Sae Young
    [J]. INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2015, 21 (06) : 801 - 802
  • [6] Aortic valve replacement:: Is the stentless xenograft an alternative to the homograft?: Midterm results
    Gross, C
    Harringer, W
    Beran, H
    Mair, R
    Sihorsch, K
    Hofmann, R
    Brücke, P
    [J]. ANNALS OF THORACIC SURGERY, 1999, 68 (03): : 919 - 924
  • [7] Left ventricle remodeling after aortic valve replacement with a stentless bioprosthesis
    Valfrè, C
    Ius, P
    Zussa, C
    Rigo, F
    Bianchini, R
    Polesel, E
    Zennaro, RJ
    [J]. JOURNAL OF HEART VALVE DISEASE, 2004, 13 : S69 - S69
  • [8] Thromboembolic acute myocardial infarction after aortic valve replacement using the Freestyle stentless aortic bioprosthesis with subcoronary valve replacement
    Watanabe, Yusuke
    Naganuma, Toru
    Kitanaka, Yosuke
    Nakamura, Sunao
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 55 (03) : 587 - 589
  • [9] Early and midterm results of aortic valve replacement using the Sorin Pericarbon Freedom Stentless aortic bioprosthesis: the Italian multicenter clinical experience
    Fabbri, A.
    Ius, P.
    Mazzucco, A.
    Zussa, C.
    Valfre, C.
    Martinelli, L.
    Casabona, R.
    Mazzola, A.
    [J]. EUROPEAN HEART JOURNAL, 2005, 26 : 284 - 284
  • [10] Valve replacement with a stentless bioprosthesis: Versatility of the porcine aortic root
    Westaby, S
    Jin, XY
    Katsumata, T
    Arifi, A
    Braidley, P
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 116 (03): : 477 - 484