Background. It is suggested that a simplified implant model Cryolife-O'Brien (CryoLife International, Kennesaw, GA) offers less satisfactory outcome compared with standard stentless models. This study was conducted to prospectively evaluate the midterm results after aortic valve replacement with the Cryolife-O'Brien stentless bioprosthesis. Methods. In 1996, a prospective clinical trial using different stentless valves was initiated. From September 1996 through September 2002, 156 consecutive patients with a mean age of 74.5 years underwent aortic valve replacement with the Cryolife-O'Brien porcine stentless bioprosthesis. The predominant aortic valve lesion was stenosis in 128 and insufficiency in 28 cases. Patients have been followed from 2 to 72 months (mean, 42 months). Echocardiography was performed by one echocardiographer preoperatively, intraoperatively, postoperatively at discharge, 2 to 6 months later, and annually thereafter. Results. Sixty percent of patients received a valve 25 mm. in diameter or larger; 39% had concomittant coronary bypass grafting. The 30-day operative mortality rate was 6.4%. Ten late nonvalve-related deaths have occurred. Severe aortic insufficiency caused by oversizing leads to early reoperation in 3 patients. The peak and mean systolic gradients decreased significantly during the first 12 months after implantation, p < 0.001, and the effective valve areas increased significantly during this time interval p < 0.001. At 5 years, ten patients have moderate aortic insufficiency. The actuarial survival at 5 years was 88 +/- 3%. The rate for freedom from endocarditis was 100% and for freedom from thromboembolic events was 94%. Conclusions. Midterm results after aortic valve replacement with the Cryolife-O'Brien stentless bioprosthesis are encouraging. Good hemodynamics have been coupled with low rate of valve-related complications, thus representing a very good alternative to conventional stented bioprostheses. (c) 2005 by The Society of Thoracic Surgeons.
引用
收藏
页码:198 / 203
页数:6
相关论文
共 50 条
  • [31] Midterm Outcomes for Valve-in-Valve Transcatheter Aortic Valve Replacement in the Failed Freestyle Bioprosthesis
    Sang, Stephane Leung Wai
    DeBruine, Nathan
    Beute, Tyler
    Heiser, John
    Berkompas, Duane
    Merhi, William
    [J]. ANNALS OF THORACIC SURGERY, 2020, 110 (06): : 1951 - 1957
  • [32] Midterm outcomes of subcoronary stentless porcine valve versus stented aortic valve replacement
    Aranda-Michel, Edgar
    Bianco, Valentino
    Dufendach, Keith
    Kilic, Arman
    Habertheuer, Andreas
    Humar, Rishab
    Navid, Forozan
    Wang, Yisi
    Sultan, Ibrahim
    [J]. JOURNAL OF CARDIAC SURGERY, 2020, 35 (11) : 2950 - 2956
  • [33] Stentless aortic bioprosthesis implantation, patient prosthesis mismatch and perioperative mortality after aortic valve replacement for aortic stenosis
    Valencia Serrano, F.
    Gomez Doblas, J. J.
    Caballero Borrego, J.
    Such, M.
    Porras, C.
    De Teresa, E.
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 : 1086 - 1086
  • [34] The upside-down stentless aortic bioprosthesis to tricuspid valve replacement
    Pisani, Paolo
    Bichi, Samuele
    Cricco, Antonio
    Pennetta, Antonio
    Esposito, Giampiero
    [J]. JOURNAL OF CARDIOVASCULAR MEDICINE, 2010, 11 (10) : 762 - 763
  • [35] Eight-year results after aortic valve replacement with the CryoLife-O'Brien Stentless Aortic Porcine Bioprosthesis
    Martinovic, I
    Farah, I
    Everlien, M
    Lindemann, S
    Knez, I
    Wittlinger, T
    Greve, H
    Vogt, P
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 130 (03): : 777 - 782
  • [36] 12-year results of aortic valve replacement with the Cryolife O'Brien stentless bioprosthesis
    Pavoni, D.
    Badano, L. P.
    Ius, F.
    Musumeci, S. F.
    Vedranin, I.
    Frassani, R.
    Mazzaro, E.
    Livi, U.
    [J]. EUROPEAN HEART JOURNAL, 2006, 27 : 733 - 733
  • [37] Is a stentless bioprosthesis the ideal prosthesis for aortic valve replacement for the elderly patient with small aortic root?
    Maribas, P
    Fromes, Y
    Deleuze, P
    Bical, O
    [J]. EUROPEAN HEART JOURNAL, 2001, 22 : 94 - 94
  • [38] Early experience of aortic valve replacement with the Freestyle stentless aortic bioprosthesis in elderly patients.
    Ohtake S.
    Sawa Y.
    Sakaguchi T.
    Nishimura M.
    Satoh H.
    Matsumiya G.
    Hayashi Y.
    Matsuda H.
    [J]. The Japanese Journal of Thoracic and Cardiovascular Surgery, 2000, 48 (4): : 222 - 228
  • [39] Aortic valve replacement with a bioprosthesis in patients with severe aortic stenosis. Stented or stentless valves?
    Andres Rodriguez-Caulo, Emiliano
    Garcia-Borbolla, Mariano
    Velazquez, Carlos J.
    Castro, Antonio
    Miranda, Nuria
    Ramirez, Bella
    Garcia-Borbolla, Rafael
    Gutierrez, Maria A.
    Perez-Duarte, Enrique
    Tellez, Juan C.
    Araji, Omar
    Barquero, Jose M.
    [J]. CIRUGIA CARDIOVASCULAR, 2013, 20 (01): : 18 - 24
  • [40] Leaflet Replacement for Aortic Stenosis Using the 3f Stentless Aortic Bioprosthesis: Midterm Results
    Risteski, Petar
    Adami, Christine
    Papadopoulos, Nestoras
    Sirat, Abdel Sami
    Moritz, Anton
    Doss, Mirko
    [J]. ANNALS OF THORACIC SURGERY, 2012, 93 (04): : 1134 - 1140