Feasibility of Using Pseudo-Continuous Arterial Spin Labeling Perfusion in a Geriatric Population at 1.5 Tesla

被引:11
|
作者
Sigurdsson, Sigurdur [1 ]
Forsberg, Lars [2 ]
Aspelund, Thor [1 ,2 ]
van der Geest, Rob J. [3 ]
van Buchem, Mark A. [3 ]
Launer, Lenore J. [4 ]
Gudnason, Vilmundur [1 ,2 ]
van Osch, Matthias J. [3 ]
机构
[1] Iceland Heart Assoc, Kopavogur, Iceland
[2] Univ Iceland, Reykjavik, Iceland
[3] Leiden Univ, Med Ctr, Dept Radiol, Leiden, Netherlands
[4] NIA, Lab Epidemiol Demog & Biometry, NIH, Bethesda, MD 20892 USA
来源
PLOS ONE | 2015年 / 10卷 / 12期
关键词
CEREBRAL-BLOOD-FLOW; ELDERLY SUBJECTS; 3.0; T; REPRODUCIBILITY; MRI; RELIABILITY; BRAIN; AGE; LOCALIZATION; RISK;
D O I
10.1371/journal.pone.0144743
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objectives To evaluate the feasibility of using pseudo-continuous arterial spin labeling (pCASL) perfusion in a geriatric population at 1.5-Tesla. Materials and Methods In 17 participants (mean age 78.8 +/- 1.63 years) we assessed; 1) inter-session repeatability and reliability of resting state perfusion in 27 brain regions; 2) brain activation using finger-tapping as a means to evaluate the ability to detect flow differences; 3) reliability by comparing cerebral blood flow (CBF) with pCASL to CBF with phase contrast (PC-MR). Results The CBF (mean +/- standard deviation (SD)) for the whole brain grey matter (GM) was 40.6 +/- 8.4 and 41.4 +/- 8.7 ml/100g/min for the first and second scan respectively. The within-subject standard deviation (SDw), the repeatability index (RI) and intra-class correlation coefficient (ICC) across the 27 regions ranged from 1.1 to 7.9, 2.2 to 15.5 and 0.35 to 0.98 respectively. For whole brain GM the SDw, RI and ICC were 1.6, 3.2 and 0.96 respectively. The between-subject standard deviation (SDB) was larger than the SDw for all regions. Comparison of CBF at rest and activation on a voxel level showed significantly higher perfusion during finger tapping in the motor-and somatosensory regions. The mean CBF for whole brain GM was 40.6 +/- 8.4 ml/100g/min at rest and 42.6 +/- 8.6 ml/100g/min during activation. Finally the reliability of pCASL against the reference standard of PC-MR was high (ICC = 0.80). The mean CBF for whole brain measured with PC-MRI was 54.3 +/- 10.1 ml/100g/min and 38.3 +/- 7.8 ml/100g/min with pCASL. Conclusions The results demonstrate moderate to high levels of repeatability and reliability for most brain regions, comparable to what has been reported for younger populations. The performance of pCASL at 1.5-Tesla shows that region-specific perfusion measurements with this technique are feasible in studies of a geriatric population.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Optimisation of pulsed and pseudo-continuous arterial spin labeling MRI techniques: A phantom study
    Yusoff, Norain
    Zukhi, Jihan
    Rusli, Awatif
    Zainon, Rafidah
    10TH INTERNATIONAL SEMINAR ON MEDICAL PHYSICS & 1ST AMDI INTERNATIONAL ONCOLOGY SYMPOSIUM, 2017, 851
  • [42] Off-resonance correction for pseudo-continuous arterial spin labeling using the optimized encoding scheme
    Berry, Eleanor S. K.
    Jezzard, Peter
    Okell, Thomas W.
    NEUROIMAGE, 2019, 199 : 304 - 312
  • [43] Reliability and Reproducibility of Hadamard Encoded Pseudo-Continuous Arterial Spin Labeling in Healthy Elderly
    Neumann, Katja
    Schidlowski, Martin
    Guenther, Matthias
    Stoecker, Tony
    Duezel, Emrah
    FRONTIERS IN NEUROSCIENCE, 2021, 15
  • [44] Fast, pseudo-continuous arterial spin labeling for functional imaging using a two-coil system
    Hernandez-Garcia, L
    Lee, GR
    Vazquez, AL
    Noll, DC
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (03) : 577 - 585
  • [45] Repeatability of perfusion measurements in adult gliomas using pulsed and pseudo-continuous arterial spin labelling MRI
    Alsaedi, Amirah Faisal
    Thomas, David Lee
    De Vita, Enrico
    Panovska-Griffiths, Jasmina
    Bisdas, Sotirios
    Golay, Xavier
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2022, 35 (01) : 113 - 125
  • [46] Reduction of BOLD interference in pseudo-continuous arterial spin labeling: towards quantitative fMRI
    Warnock, Geoffrey
    Oezbay, Pinar S.
    Kuhn, Felix P.
    Nanz, Daniel
    Buck, Alfred
    Boss, Andreas
    Rossi, Cristina
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2018, 38 (05): : 847 - 856
  • [47] Repeatability of perfusion measurements in adult gliomas using pulsed and pseudo-continuous arterial spin labelling MRI
    Amirah Faisal Alsaedi
    David Lee Thomas
    Enrico De Vita
    Jasmina Panovska-Griffiths
    Sotirios Bisdas
    Xavier Golay
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2022, 35 : 113 - 125
  • [48] Measurement of skeletal muscle perfusion dynamics with pseudo-continuous arterial spin labeling (pCASL): Assessment of relative labeling efficiency at rest and during hyperemia, and comparison to pulsed arterial spin labeling (PASL)
    Englund, Erin K.
    Rodgers, Zachary B.
    Langham, Michael C.
    Mohler, Emile R., III
    Floyd, Thomas F.
    Wehrli, Felix W.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (04) : 929 - 939
  • [49] Feasibility of high-resolution perfusion imaging using arterial spin labeling MRI at 3 Tesla
    Kashyap, Sriranga
    Oliveira, icaro Agenor Ferreira
    Uludag, Kamil
    FRONTIERS IN PHYSIOLOGY, 2024, 14
  • [50] A systematic study of the sensitivity of partial volume correction methods for the quantification of perfusion from pseudo-continuous arterial spin labeling MRI
    Zhao, Moss Y.
    Mezue, Melvin
    Segerdahl, Andrew R.
    Okell, Thomas W.
    Tracey, Irene
    Xiao, Yingyi
    Chappell, Michael A.
    NEUROIMAGE, 2017, 162 : 384 - 397