Reduction of BOLD interference in pseudo-continuous arterial spin labeling: towards quantitative fMRI

被引:2
|
作者
Warnock, Geoffrey [1 ]
Oezbay, Pinar S. [2 ,3 ,4 ,5 ]
Kuhn, Felix P. [2 ]
Nanz, Daniel [2 ]
Buck, Alfred [1 ]
Boss, Andreas [2 ]
Rossi, Cristina [2 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Dept Nucl Med, Zurich, Switzerland
[2] Univ Zurich, Inst Diagnost & Intervent Radiol, Univ Hosp Zurich, Raemistr 100, CH-8091 Zurich, Switzerland
[3] Univ Zurich, Inst Biomed Engn, Zurich, Switzerland
[4] Swiss Fed Inst Technol, Zurich, Switzerland
[5] NINDS, Adv MRI Sect, Lab Funct & Mol Imaging, NIH, Bldg 36,Rm 4D04, Bethesda, MD 20892 USA
来源
关键词
Arterial spin labelling; cerebral blood flow measurement; MRI; positron emission tomography; CEREBRAL-BLOOD-FLOW; POSITRON-EMISSION-TOMOGRAPHY; PERFUSION MRI; FIELD-STRENGTH; WHOLE-BRAIN; 3.0; T; CAFFEINE; ECHO; PET; SENSITIVITY;
D O I
10.1177/0271678X17704785
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Fluctuations in blood-oxygenation level dependent (BOLD) signal and perfusion affect the quantification of changes in cerebral blood flow (CBF), coupled to neuronal activity, in arterial spin labeling (ASL). Subtraction methods for control and labeled MR images (i.e. pair-wise, surround subtraction, and subtraction of sinc-interpolated images), postulated to mitigate this interference in pseudo-continuous ASL (pCASL), were evaluated by comparison with quantitative O-15-water PET. At rest, a good agreement in the CBF values was found between PET and MRI for each of the subtraction methods. Stimulation of the visual system resulted in a regional CBF increase in the occipital lobe, which was detectable in both modalities. Bland-Altman analysis showed a systematic underestimation of the CBF values during activation in MRI. Evaluation of the relative CBF change induced by neuronal stimulation showed good inter-modality agreement for the three subtraction methods. Perfusion data obtained with each subtraction method followed the stimulation paradigm without significant differences in the correlation patterns or in the time lag between stimulation and perfusion response. Comparison to the gold standard confirmed the detectability of a neuronal stimulation pattern by pCASL. The results indicate that the combined use of background suppression and short TE reduces the BOLD-weighting in the pCASL signal.
引用
收藏
页码:847 / 856
页数:10
相关论文
共 50 条
  • [1] Acoustic noise reduction in pseudo-continuous arterial spin labeling (pCASL)
    Johan N. van der Meer
    Dennis F. R. Heijtel
    Guus van Hest
    Geert-Jan Plattèl
    Matthijs J. P. van Osch
    Eus J. W. van Someren
    Ed T. vanBavel
    Aart J. Nederveen
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2014, 27 : 269 - 276
  • [2] Acoustic noise reduction in pseudo-continuous arterial spin labeling (pCASL)
    van der Meer, Johan N.
    Heijtel, Dennis F. R.
    van Hest, Guus
    Plattel, Geert-Jan
    van Osch, Matthijs J. P.
    van Someren, Eus J. W.
    vanBavel, Ed T.
    Nederveen, Aart J.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2014, 27 (03) : 269 - 276
  • [3] Superselective pseudo-continuous arterial spin labeling angiography
    Jensen-Kondering, Ulf
    Lindner, Thomas
    van Osch, Matthias J. P.
    Rohr, Axel
    Jansen, Olav
    Helle, Michael
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (09) : 1758 - 1767
  • [4] AN EXPERIMENTAL INVESTIGATION OF LABELING EFFICIENCY FOR PSEUDO-CONTINUOUS ARTERIAL SPIN LABELING
    Chai, Yaqiong
    Bush, Adam
    Coloigner, Julie
    Qu, Xiaoping
    Chia, Jonathan
    Lepore, Natasha
    Wood, John
    2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, : 1101 - 1104
  • [5] Characterization of Pseudo-Continuous Arterial Spin Labeling: Simulations and Experimental Validation
    Lorenz, Kathrin
    Mildner, Toralf
    Schlumm, Torsten
    Moeller, Harald E.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1638 - 1649
  • [6] Pseudo-continuous arterial spin labeling MRI study of schizophrenic patients
    Ota, Miho
    Ishikawa, Masanori
    Sato, Noriko
    Okazaki, Mitsutoshi
    Maikusa, Norihide
    Hori, Hiroaki
    Hattori, Kotaro
    Teraishi, Toshiya
    Ito, Kimiteru
    Kunugi, Hiroshi
    SCHIZOPHRENIA RESEARCH, 2014, 154 (1-3) : 113 - 118
  • [7] Optimization of pseudo-continuous arterial spin labeling for renal perfusion imaging
    Echeverria-Chasco, Rebeca
    Vidorreta, Marta
    Aramendia-Vidaurreta, Veronica
    Cano, David
    Escalada, Javier
    Garcia-Fernandez, Nuria
    Bastarrika, Gorka
    Fernandez-Seara, Maria A.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (03) : 1507 - 1521
  • [8] Improved Pseudo-Continuous Arterial Spin Labeling for Mapping Brain Perfusion
    Nezamzadeh, Marzieh
    Matson, Gerald B.
    Young, Karl
    Weiner, Michael W.
    Schuff, Norbert
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (06) : 1419 - 1427
  • [9] Robust estimation of quantitative perfusion from multi-phase pseudo-continuous arterial spin labeling
    Msayib, Y.
    Craig, M.
    Simard, M. A.
    Larkin, J. R.
    Shin, D. D.
    Liu, T. T.
    Sibson, N. R.
    Okell, T. W.
    Chappell, M. A.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (03) : 815 - 829
  • [10] Optimization of adiabatic pulses for pulsed arterial spin labeling at 7 tesla: Comparison with pseudo-continuous arterial spin labeling
    Wang, Kai
    Shao, Xingfeng
    Yan, Lirong
    Ma, Samantha J.
    Jin, Jin
    Wang, Danny J. J.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (06) : 3227 - 3240