Feasibility of high-resolution perfusion imaging using arterial spin labeling MRI at 3 Tesla

被引:3
|
作者
Kashyap, Sriranga [1 ]
Oliveira, icaro Agenor Ferreira [1 ]
Uludag, Kamil [1 ,2 ,3 ,4 ,5 ]
机构
[1] Univ Hlth Network, Krembil Brain Inst, Toronto, ON, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[3] Inst Basic Sci, Ctr Neurosci Imaging Res, Suwon, South Korea
[4] Sungkyunkwan Univ, Dept Biomed Engn, Suwon, South Korea
[5] Sunnybrook Res Inst, Phys Sci, Toronto, ON, Canada
关键词
arterial spin labeling; brain perfusion; high spatial resolution; 3; Tesla; RF coil; neuroimaging frontiers; SURFACE-BASED ANALYSIS; VOLUMETRIC NAVIGATORS; PROSPECTIVE MOTION; BRAIN MORPHOMETRY; SEGMENTATION; TIME; IMPLEMENTATION; VISUALIZATION; INVERSION; INFERENCE;
D O I
10.3389/fphys.2023.1271254
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Cerebral blood flow (CBF) is a critical physiological parameter of brain health, and it can be non-invasively measured with arterial spin labeling (ASL) MRI. In this study, we evaluated and optimized whole-brain, high-resolution ASL as an alternative to the low-resolution ASL employed in the routine assessment of CBF in both healthy participants and patients. Two high-resolution protocols (i.e., pCASL and FAIR-Q2TIPS (PASL) with 2 mm isotropic voxels) were compared to a default clinical pCASL protocol (3.4 x 3.4 x 4 mm3), all of whom had an acquisition time of approximate to 5 min. We assessed the impact of high-resolution acquisition on reducing partial voluming and improving sensitivity to the perfusion signal, and evaluated the effectiveness of z-deblurring on the ASL data. We compared the quality of whole-brain ASL acquired using three available head coils with differing number of receive channels (i.e., 20, 32, and 64ch). We found that using higher coil counts (32 and 64ch coils as compared to 20ch) offers improved signal-to-noise ratio (SNR) and acceleration capabilities that are beneficial for ASL imaging at 3 Tesla (3 T). The inherent reduction in partial voluming effects with higher resolution acquisitions improves the resolving power of perfusion without impacting the sensitivity. In conclusion, our results suggest that high-resolution ASL (2 to 2.5 mm isotropic voxels) has the potential to become a new standard for perfusion imaging at 3 T and increase its adoption into clinical research and cognitive neuroscience applications.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Cerebral perfusion MRI with arterial spin labeling technique at 0.5 Tesla
    Tsuchiya, K
    Katase, S
    Hachiya, J
    Kimura, T
    Yodo, K
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (01) : 124 - 127
  • [2] Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 tesla
    Wang, JJ
    Alsop, DC
    Li, L
    Listerud, J
    Gonzalez-At, JB
    Schnall, MD
    Detre, JA
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) : 242 - 254
  • [3] Chronic and treatment-resistant depression: A study using arterial spin labeling perfusion MRI at 3 Tesla
    Duhameau, Berengere
    Ferre, Jean-Christophe
    Jannin, Pierre
    Gauvrit, Jean-Yves
    Verin, Marc
    Millet, Bruno
    Drapier, Dominique
    PSYCHIATRY RESEARCH-NEUROIMAGING, 2010, 182 (02) : 111 - 116
  • [4] Intracranial arterial wall imaging using high-resolution 3-tesla contrast-enhanced MRI
    Swartz, R. H.
    Bhuta, S. S.
    Farb, R. I.
    Agid, R.
    Willinsky, R. A.
    Terbrugge, K. G.
    Butany, J.
    Wasserman, B. A.
    Johnstone, D. M.
    Silver, F. L.
    Mikulis, D. J.
    NEUROLOGY, 2009, 72 (07) : 627 - 634
  • [5] Feasibility of high-resolution pituitary MRI at 7.0 tesla
    Alexandra A. J. de Rotte
    Anja G. van der Kolk
    Dik Rutgers
    Pierre M. J. Zelissen
    Fredy Visser
    Peter R. Luijten
    Jeroen Hendrikse
    European Radiology, 2014, 24 : 2005 - 2011
  • [6] Feasibility of high-resolution pituitary MRI at 7.0 tesla
    de Rotte, Alexandra A. J.
    van der Kolk, Anja G.
    Rutgers, Dik
    Zelissen, Pierre M. J.
    Visser, Fredy
    Luijten, Peter R.
    Hendrikse, Jeroen
    EUROPEAN RADIOLOGY, 2014, 24 (08) : 2005 - 2011
  • [7] Feasibility of Using Pseudo-Continuous Arterial Spin Labeling Perfusion in a Geriatric Population at 1.5 Tesla
    Sigurdsson, Sigurdur
    Forsberg, Lars
    Aspelund, Thor
    van der Geest, Rob J.
    van Buchem, Mark A.
    Launer, Lenore J.
    Gudnason, Vilmundur
    van Osch, Matthias J.
    PLOS ONE, 2015, 10 (12):
  • [8] Improved Arterial Spin Labeling Perfusion Method to Measure White Matter Perfusion at a 4 Tesla MRI
    Jahng, G. H.
    Weiner, M. W.
    Schuff, N.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1463 - +
  • [9] Quantitative perfusion imaging using arterial spin labeling
    Wong, EC
    Buxton, RB
    Frank, LR
    NEUROIMAGING CLINICS OF NORTH AMERICA, 1999, 9 (02) : 333 - 342
  • [10] High Resolution Imaging of Intracranial Arterial Dissection by 3-Tesla MRI
    Okatsu, Hidelki
    Koga, Masatoshi
    Matsuolka, Hidelki
    Furuta, Konosulke
    Toyoda, Kazumori
    Uehara, Toshiyuki
    Yamamoto, Alkihide
    Sato, Hiroshi
    Hayashi, Takuya
    Lida, Hidehiro
    Naritomi, Hiroaki
    Kazuo, Minematsu
    STROKE, 2009, 40 (04) : E203 - E204