Feasibility of high-resolution pituitary MRI at 7.0 tesla

被引:24
|
作者
de Rotte, Alexandra A. J. [1 ]
van der Kolk, Anja G. [1 ]
Rutgers, Dik [1 ]
Zelissen, Pierre M. J. [2 ]
Visser, Fredy [1 ,3 ]
Luijten, Peter R. [1 ]
Hendrikse, Jeroen [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, NL-3508 GA Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Internal Med, Sect Endocrinol, NL-3508 GA Utrecht, Netherlands
[3] Philips Healthcare, Best, Netherlands
关键词
Pituitary gland; Cushing's disease; Pituitary; Magnetic resonance imaging; INITIAL-EXPERIENCE; CUSHINGS-SYNDROME; SELLAR LESIONS; DISEASE; BRAIN; DIAGNOSIS; TUMORS;
D O I
10.1007/s00330-014-3230-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Since the pituitary gland measures 3-8 mm, imaging with the highest possible spatial resolution is important for the detection of even smaller lesions such as those seen in Cushing's disease. In the current feasibility study, we tested a multi-sequence MRI protocol to visualize the pituitary gland in high resolution at 7.0 Tesla (7.0 T). Ten healthy volunteers were examined with a 7.0 T pituitary gland protocol. The protocol consisted of a T1-weighted magnetization-prepared inversion recovery (MPIR) turbo spin-echo (TSE) sequence and a T2-weighted TSE sequence. Additionally, this protocol was tested in five patients with clinical and biochemical suspicion of a microadenoma. The dedicated protocol was successful in visualizing normal pituitary anatomy. At 7.0 T compared to 1.5 T, four times as many slices covered the pituitary gland in sagittal and coronal direction. In three patients, a lesion was diagnosed at 7.0 T, and was confirmed by histopathology to be a microadenoma. Head-to-head comparisons of 7.0 T with 1.5 T and 3.0 T are needed with larger samples of patients and with imaging times feasible for clinical settings. However, the current study suggests that high-resolution 7.0 T MRI of the pituitary gland may provide new perspectives when used as a second-line diagnostic examination in the specific context of Cushing's disease. aEuro cent 7.0 T MRI enables ultra-high-resolution imaging of the pituitary gland. aEuro cent 7.0 T MRI is appropriate to visualize normal pituitary gland anatomy. aEuro cent The pituitary protocol consists of a T (1) -MPIR-TSE and a T (2) -TSE sequence. aEuro cent In four patients, a suspected ACTH-producing microadenoma was visualized at 7.0 T. aEuro cent Histopathology confirmed three of four lesions to be ACTH-producing microadenomas.
引用
收藏
页码:2005 / 2011
页数:7
相关论文
共 50 条
  • [1] Feasibility of high-resolution pituitary MRI at 7.0 tesla
    Alexandra A. J. de Rotte
    Anja G. van der Kolk
    Dik Rutgers
    Pierre M. J. Zelissen
    Fredy Visser
    Peter R. Luijten
    Jeroen Hendrikse
    [J]. European Radiology, 2014, 24 : 2005 - 2011
  • [2] High resolution pituitary gland MRI at 7.0 tesla: a clinical evaluation in Cushing's disease
    de Rotte, Alexandra A. J.
    Groenewegen, Amy
    Rutgers, Dik R.
    Witkamp, Theo
    Zelissen, Pierre M. J.
    Meijer, F. J. Anton
    van Lindert, Erik J.
    Hermus, Ad
    Luijten, Peter R.
    Hendrikse, Jeroen
    [J]. EUROPEAN RADIOLOGY, 2016, 26 (01) : 271 - 277
  • [3] High resolution pituitary gland MRI at 7.0 tesla: a clinical evaluation in Cushing’s disease
    Alexandra A. J. de Rotte
    Amy Groenewegen
    Dik R. Rutgers
    Theo Witkamp
    Pierre M. J. Zelissen
    F. J. Anton Meijer
    Erik J. van Lindert
    Ad Hermus
    Peter R. Luijten
    Jeroen Hendrikse
    [J]. European Radiology, 2016, 26 : 271 - 277
  • [4] High-Resolution MRI of the Cerebellum at 7.0 T
    Dietrich, Olaf
    [J]. RADIOLOGY, 2023, 307 (02)
  • [5] HIGH-RESOLUTION MRI OF THE FINGERS AT 0.1 TESLA
    CONSTANTINESCO, A
    XU, F
    ARBOGAST, S
    BRUNOT, B
    DRAPE, JL
    FACELLO, A
    FOUCHER, G
    [J]. JOURNAL DE MEDECINE NUCLEAIRE ET BIOPHYSIQUE, 1992, 16 (02): : 146 - 149
  • [6] Feasibility of high-resolution perfusion imaging using arterial spin labeling MRI at 3 Tesla
    Kashyap, Sriranga
    Oliveira, icaro Agenor Ferreira
    Uludag, Kamil
    [J]. FRONTIERS IN PHYSIOLOGY, 2024, 14
  • [7] MRI AND HIGH-RESOLUTION CT OF PITUITARY ABSCESS
    DICKOB, M
    SCHARPHUIS, T
    DISTELMAIER, P
    HOFFMANN, G
    [J]. NEUROCHIRURGIA, 1989, 32 (06) : 184 - 186
  • [8] Feasibility of Contrast-enhanced and High-resolution 7 Tesla MRI in Patients with Suspicious Breast Lesions
    Stehouwer, B. L.
    Klomp, D. W. J.
    Luijten, P. R.
    Houwert, K. A. F.
    van Diest, P. J.
    Mali, W. P. T. M.
    van den Bosch, M. A. A. J.
    Veldhuis, W. B.
    [J]. EUROPEAN JOURNAL OF CANCER, 2012, 48 : S70 - S70
  • [9] MRI of the knee at 7.0 Tesla
    Kraff, Oliver
    Theysohn, J. M.
    Maderwald, S.
    Saylor, C.
    Ladd, S. C.
    Ladd, M. E.
    Barkhausen, J.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2007, 179 (12): : 1231 - 1235
  • [10] Dynamic contrast-enhanced and ultra-high-resolution breast MRI at 7.0 Tesla
    Stehouwer, Bertine L.
    Klomp, Dennis W. J.
    van den Bosch, Maurice A. A. J.
    Korteweg, Mies A.
    Gilhuijs, Kenneth G. A.
    Witkamp, Arjen J.
    van Diest, Paul J.
    Houwert, Karel A. F.
    van der Kemp, Wybe J. M.
    Luijten, Peter R.
    Mali, W. P. Th. M.
    Veldhuis, Wouter B.
    [J]. EUROPEAN RADIOLOGY, 2013, 23 (11) : 2961 - 2968