Rapid simultaneous acquisition of T1 and T2 mapping images using multishot double spin-echo EPI and automated variations of TR and TE (ms-DSEPI-T12)

被引:8
|
作者
Liu, Xin [2 ]
Feng, Yi [3 ]
Lu, Zheng-Rong [4 ]
Morrell, Glen
Jeong, Eun-Kee [1 ]
机构
[1] Univ Utah, Dept Radiol, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84108 USA
[2] Univ Utah, Dept Phys, Salt Lake City, UT 84108 USA
[3] Univ Utah, Dept Mat Engn, Salt Lake City, UT 84108 USA
[4] Univ Utah, Dept Pharmaceut & Pharmaceut Chem, Salt Lake City, UT 84108 USA
关键词
T-1/T-2; maps; T-1; map; T-2; rapid T-1/T-2 maps; simultaneous T-1/T-2 maps; Delta R-1(r; t) map; multishot double spin-echo EPI; dynamic contrast MRI; GD-DTPA ENHANCEMENT; PHARMACOKINETIC ANALYSIS; GADOLINIUM-DTPA; CONTRAST AGENT; MRI; PERMEABILITY; EXPERIENCE; TUMORS;
D O I
10.1002/nbm.1440
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A rapid method of simultaneous T-1 and T-2 measurement is presented which uses a segmented echo-planar readout with varying repetition times (TR) and echo times (TIE). This method is useful in T-1 mapping for analysis of dynamic contrast enhanced MRI (DCE-MRI), where T-1 can be used to estimate contrast agent concentration. In the application of this method to dynamic imaging, the equilibrium magnetization is measured on pre-contrast images and incorporated into post-contrast T-1 calculations for improved accuracy. Simultaneous T-2 measurement allows correction of T-2 effects in the T-1 map which may occur at high contrast agent concentrations, and is performed without significant imaging time penalty. Phantom and in vivo results show the usefulness of this technique for analysis of contrast enhancement kinetics. Accurate rapid contrast agent concentration measurement may be useful for analyzing the distribution and kinetics of contrast agents or labeled pharmaceuticals. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 50 条
  • [31] Myocardial T2* Mapping Free of Distortion Using Susceptibility-Weighted Fast Spin-Echo Imaging: A Feasibility Study at 1.5 T and 3.0 T
    Heinrichs, Uwe
    Utting, Jane F.
    Frauenrath, Tobias
    Hezel, Fabian
    Krombach, Gabriele A.
    Hodenius, Michael A. J.
    Kozerke, Sebastian
    Niendorf, Thoralf
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (03) : 822 - 828
  • [32] Simultaneous Mapping of T1 and T2 Using Cardiac Magnetic Resonance Fingerprinting in a Cohort of Healthy Subjects at 1.5T
    Hamilton, Jesse I.
    Pahwa, Shivani
    Adedigba, Joseph
    Frankel, Samuel
    O'Connor, Gregory
    Thomas, Rahul
    Walker, Jonathan R.
    Killinc, Ozden
    Lo, Wei-Ching
    Batesole, Joshua
    Margevicius, Seunghee
    Griswold, Mark
    Rajagopalan, Sanjay
    Gulani, Vikas
    Seiberlich, Nicole
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 52 (04) : 1044 - 1052
  • [33] MS Lesions Are Better Detected with 3D T1 Gradient-Echo Than with 2D T1 Spin-Echo Gadolinium-Enhanced Imaging at 3T
    Crombe, A.
    Saranathan, M.
    Ruet, A.
    Durieux, M.
    de Roquefeuil, E.
    Ouallet, J. C.
    Brochet, B.
    Dousset, V.
    Tourdias, T.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (03) : 501 - 507
  • [34] Oxygen enhanced lung MRI by simultaneous measurement of T1 and T2* during free breathing using ultrashort TE
    Triphan, Simon M. F.
    Breuer, Felix A.
    Gensler, Daniel
    Kauczor, Hans-Ulrich
    Jakob, Peter M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (06) : 1708 - 1714
  • [35] Editorial for "Simultaneous Mapping of T1 and T2 Using Cardiac Magnetic Resonance Fingerprinting in a Cohort of Healthy Subjects at 1.5T"
    Nezafat, Reza
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 52 (04) : 1053 - 1054
  • [36] Model-Based Nonlinear Inverse Reconstruction for T2 Mapping Using Highly Undersampled Spin-Echo MRI
    Sumpf, Tilman J.
    Uecker, Martin
    Boretius, Susann
    Frahm, Jens
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (02) : 420 - 428
  • [37] Myocardial T2* mapping free of distortion using susceptibility weighted spin-echo based imaging: a feasibility study
    Uwe Heinrichs
    Jane F Utting
    Fabian Hezel
    Gabriele A Krombach
    Sebastian Kozerke
    Thoralf Niendorf
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [38] Accelerated Cardiac T2 Mapping using Breath-hold Multiecho Fast Spin-Echo Pulse Sequence with k-t FOCUSS
    Feng, Li
    Otazo, Ricardo
    Jung, Hong
    Jensen, Jens H.
    Ye, Jong C.
    Sodickson, Daniel K.
    Kim, Daniel
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (06) : 1661 - 1669
  • [39] Quantitative mapping of transverse relaxivity (1/T2) in hepatic iron overload:: a single spin-echo imaging methodology
    Clark, PR
    St Pierre, TG
    MAGNETIC RESONANCE IMAGING, 2000, 18 (04) : 431 - 438
  • [40] Cardiac MRF using rosette trajectories for simultaneous myocardial T1, T2, and proton density fat fraction mapping
    Liu, Yuchi
    Hamilton, Jesse
    Jiang, Yun
    Seiberlich, Nicole
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9