Rapid simultaneous acquisition of T1 and T2 mapping images using multishot double spin-echo EPI and automated variations of TR and TE (ms-DSEPI-T12)
被引:8
|
作者:
Liu, Xin
论文数: 0引用数: 0
h-index: 0
机构:
Univ Utah, Dept Phys, Salt Lake City, UT 84108 USAUniv Utah, Dept Radiol, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84108 USA
Liu, Xin
[2
]
Feng, Yi
论文数: 0引用数: 0
h-index: 0
机构:
Univ Utah, Dept Mat Engn, Salt Lake City, UT 84108 USAUniv Utah, Dept Radiol, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84108 USA
Feng, Yi
[3
]
Lu, Zheng-Rong
论文数: 0引用数: 0
h-index: 0
机构:
Univ Utah, Dept Pharmaceut & Pharmaceut Chem, Salt Lake City, UT 84108 USAUniv Utah, Dept Radiol, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84108 USA
Lu, Zheng-Rong
[4
]
Morrell, Glen
论文数: 0引用数: 0
h-index: 0
机构:Univ Utah, Dept Radiol, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84108 USA
Morrell, Glen
Jeong, Eun-Kee
论文数: 0引用数: 0
h-index: 0
机构:
Univ Utah, Dept Radiol, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84108 USAUniv Utah, Dept Radiol, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84108 USA
Jeong, Eun-Kee
[1
]
机构:
[1] Univ Utah, Dept Radiol, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84108 USA
[2] Univ Utah, Dept Phys, Salt Lake City, UT 84108 USA
[3] Univ Utah, Dept Mat Engn, Salt Lake City, UT 84108 USA
[4] Univ Utah, Dept Pharmaceut & Pharmaceut Chem, Salt Lake City, UT 84108 USA
A rapid method of simultaneous T-1 and T-2 measurement is presented which uses a segmented echo-planar readout with varying repetition times (TR) and echo times (TIE). This method is useful in T-1 mapping for analysis of dynamic contrast enhanced MRI (DCE-MRI), where T-1 can be used to estimate contrast agent concentration. In the application of this method to dynamic imaging, the equilibrium magnetization is measured on pre-contrast images and incorporated into post-contrast T-1 calculations for improved accuracy. Simultaneous T-2 measurement allows correction of T-2 effects in the T-1 map which may occur at high contrast agent concentrations, and is performed without significant imaging time penalty. Phantom and in vivo results show the usefulness of this technique for analysis of contrast enhancement kinetics. Accurate rapid contrast agent concentration measurement may be useful for analyzing the distribution and kinetics of contrast agents or labeled pharmaceuticals. Copyright (C) 2009 John Wiley & Sons, Ltd.
机构:
NYU, Sch Med, Dept Radiol, Bernard & Irene Schwartz Ctr Biomed Imaging, 660 1st Ave,4th Floor, New York, NY 10016 USANYU, Sch Med, Dept Radiol, Bernard & Irene Schwartz Ctr Biomed Imaging, 660 1st Ave,4th Floor, New York, NY 10016 USA
Sharafi, Azadeh
Zibetti, Marcelo V. W.
论文数: 0引用数: 0
h-index: 0
机构:
NYU, Sch Med, Dept Radiol, Bernard & Irene Schwartz Ctr Biomed Imaging, 660 1st Ave,4th Floor, New York, NY 10016 USANYU, Sch Med, Dept Radiol, Bernard & Irene Schwartz Ctr Biomed Imaging, 660 1st Ave,4th Floor, New York, NY 10016 USA
Zibetti, Marcelo V. W.
Chang, Gregory
论文数: 0引用数: 0
h-index: 0
机构:
NYU, Sch Med, Dept Radiol, Bernard & Irene Schwartz Ctr Biomed Imaging, 660 1st Ave,4th Floor, New York, NY 10016 USANYU, Sch Med, Dept Radiol, Bernard & Irene Schwartz Ctr Biomed Imaging, 660 1st Ave,4th Floor, New York, NY 10016 USA
Chang, Gregory
Cloos, Martijn
论文数: 0引用数: 0
h-index: 0
机构:
NYU, Sch Med, Dept Radiol, Bernard & Irene Schwartz Ctr Biomed Imaging, 660 1st Ave,4th Floor, New York, NY 10016 USANYU, Sch Med, Dept Radiol, Bernard & Irene Schwartz Ctr Biomed Imaging, 660 1st Ave,4th Floor, New York, NY 10016 USA
Cloos, Martijn
Regatte, Ravinder R.
论文数: 0引用数: 0
h-index: 0
机构:
NYU, Sch Med, Dept Radiol, Bernard & Irene Schwartz Ctr Biomed Imaging, 660 1st Ave,4th Floor, New York, NY 10016 USANYU, Sch Med, Dept Radiol, Bernard & Irene Schwartz Ctr Biomed Imaging, 660 1st Ave,4th Floor, New York, NY 10016 USA