A Technique for Rapid Single-Echo Spin-Echo T2 Mapping

被引:18
|
作者
Sussman, Marshall S. [1 ]
Vidarsson, Logi
Pauly, John M. [3 ]
Cheng, Hai-Ling Margaret [2 ,4 ,5 ]
机构
[1] Univ Hlth Network, Toronto, ON, Canada
[2] Hosp Sick Children, Dept Diagnost Imaging, Toronto, ON M5G 1X8, Canada
[3] Stanford Univ, Stanford, CA 94305 USA
[4] Hosp Sick Children, Inst Res, Toronto, ON M5G 1X8, Canada
[5] Univ Toronto, Toronto, ON, Canada
关键词
T-2; mapping; rapid imaging; transverse relaxation; single echo spin echo; volumetric imaging; human imaging; NUCLEAR-MAGNETIC-RESONANCE; CARTILAGE REPAIR; MRI TECHNIQUES; STEADY-STATE; T2; RELAXATION; ACQUISITION; DEPENDENCE; SEQUENCE; TISSUE;
D O I
10.1002/mrm.22454
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A rapid technique for mapping of T-2 relaxation times is presented. The method is based on the conventional single-echo spin echo approach but uses a much shorter pulse repetition time to accelerate data acquisition. The premise of the new method is the use of a constant difference between the echo time and pulse repetition time, which removes the conventional and restrictive requirement of pulse repetition time >> T-1. Theoretical and simulation investigations were performed to evaluate the criteria for accurate T-2 measurements. Measured T(2)s were shown to be within 1% error as long as the key criterion of pulse repetition time/T-2 >= 3 is met. Strictly, a second condition of echo time/T-1 << 1 is also required. However, violations of this condition were found to have minimal impact in most clinical scenarios. Validation was conducted in phantoms and in vivo T-2 mapping of healthy cartilage and brain. The proposed method offers all the advantages of single-echo spin echo imaging (e.g., immunity to stimulated echo effects, robustness to static field inhomogeneity, flexibility in the number and choice of echo times) in a considerably reduced amount of time and is readily implemented on any clinical scanner. Magn Reson Med 64:536-545, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:536 / 545
页数:10
相关论文
共 50 条
  • [1] A short-TR single-echo spin-echo breath-hold method for assessing liver T2
    Marshall S. Sussman
    Kartik S. Jhaveri
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2024, 37 : 101 - 113
  • [2] A short-TR single-echo spin-echo breath-hold method for assessing liver T2
    Sussman, Marshall S.
    Jhaveri, Kartik S.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2024, 37 (01) : 101 - 113
  • [3] Comparison of single-echo T2-weighted fast spin-echo and conventional spin-echo MR sequences - In the detection of brain lesions of multiple sclerosis
    Sparacia, G
    Angileri, T
    Banco, A
    Miraglia, R
    Nicastro, T
    Lagalla, R
    RIVISTA DI NEURORADIOLOGIA, 1998, 11 (04): : 471 - 476
  • [4] SINGLE SCAN SPIN-ECHO MEASUREMENTS OF T1 AND T2
    COSGROVE, T
    JOURNAL OF MAGNETIC RESONANCE, 1976, 21 (03) : 469 - 472
  • [5] Fast T2 mapping using multi-echo spin-echo MRI: A linear order approach
    Fatemi, Yaghoub
    Danyali, Habibollah
    Helfroush, Mohammad Sadegh
    Amiri, Houshang
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (05) : 2815 - 2830
  • [6] Fast T2 Relaxometry with an Accelerated Multi-echo Spin-echo Sequence
    Senegas, Julien
    Liu, Wei
    Dahnke, Hannes
    Song, Hotaek
    Jordan, E. Kay
    Frank, Joseph A.
    NMR IN BIOMEDICINE, 2010, 23 (08) : 958 - 967
  • [7] T2 mapping of the heart with a double-inversion radial fast spin-echo method with indirect echo compensation
    Tomoe Hagio
    Chuan Huang
    Aiden Abidov
    Jaspreet Singh
    Bujji Ainapurapu
    Scott Squire
    Denise Bruck
    Maria I Altbach
    Journal of Cardiovascular Magnetic Resonance, 17
  • [8] T2 mapping of the heart with a double-inversion radial fast spin-echo method with indirect echo compensation
    Hagio, Tomoe
    Huang, Chuan
    Abidov, Aiden
    Singh, Jaspreet
    Ainapurapu, Bujji
    Squire, Scott
    Bruck, Denise
    Altbach, Maria I.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
  • [9] MINIMIZING ERRORS IN T2 DETERMINATIONS WITH SPIN-ECHO EQUIPMENT
    MEHLKOPF, AF
    SMIDT, J
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1966, 43 (04): : 253 - &
  • [10] SURFACE EFFECTS MEASURED BY ADDITIONAL ECHO DECAY IN THE T2 HAHN SPIN-ECHO EXPERIMENT
    LEON, V
    DIAZ, H
    APPLIED SPECTROSCOPY, 1986, 40 (03) : 416 - 416