Rapid simultaneous acquisition of T1 and T2 mapping images using multishot double spin-echo EPI and automated variations of TR and TE (ms-DSEPI-T12)

被引:8
|
作者
Liu, Xin [2 ]
Feng, Yi [3 ]
Lu, Zheng-Rong [4 ]
Morrell, Glen
Jeong, Eun-Kee [1 ]
机构
[1] Univ Utah, Dept Radiol, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84108 USA
[2] Univ Utah, Dept Phys, Salt Lake City, UT 84108 USA
[3] Univ Utah, Dept Mat Engn, Salt Lake City, UT 84108 USA
[4] Univ Utah, Dept Pharmaceut & Pharmaceut Chem, Salt Lake City, UT 84108 USA
关键词
T-1/T-2; maps; T-1; map; T-2; rapid T-1/T-2 maps; simultaneous T-1/T-2 maps; Delta R-1(r; t) map; multishot double spin-echo EPI; dynamic contrast MRI; GD-DTPA ENHANCEMENT; PHARMACOKINETIC ANALYSIS; GADOLINIUM-DTPA; CONTRAST AGENT; MRI; PERMEABILITY; EXPERIENCE; TUMORS;
D O I
10.1002/nbm.1440
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A rapid method of simultaneous T-1 and T-2 measurement is presented which uses a segmented echo-planar readout with varying repetition times (TR) and echo times (TIE). This method is useful in T-1 mapping for analysis of dynamic contrast enhanced MRI (DCE-MRI), where T-1 can be used to estimate contrast agent concentration. In the application of this method to dynamic imaging, the equilibrium magnetization is measured on pre-contrast images and incorporated into post-contrast T-1 calculations for improved accuracy. Simultaneous T-2 measurement allows correction of T-2 effects in the T-1 map which may occur at high contrast agent concentrations, and is performed without significant imaging time penalty. Phantom and in vivo results show the usefulness of this technique for analysis of contrast enhancement kinetics. Accurate rapid contrast agent concentration measurement may be useful for analyzing the distribution and kinetics of contrast agents or labeled pharmaceuticals. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 50 条
  • [21] 3D magnetic resonance fingerprinting for rapid simultaneous T1, T2, and T1ρ volumetric mapping of human articular cartilage at 3 T
    Sharafi, Azadeh
    Zibetti, Marcelo V. W.
    Chang, Gregory
    Cloos, Martijn
    Regatte, Ravinder R.
    NMR IN BIOMEDICINE, 2022, 35 (12)
  • [22] Automated Inline Myocardial Segmentation of Joint T1 and T2 Mapping Using Deep Learning
    Howard, James P.
    Chow, Kelvin
    Chacko, Liza
    Fontana, Mariana
    Cole, Graham D.
    Kellman, Peter
    Xue, Hui
    RADIOLOGY-ARTIFICIAL INTELLIGENCE, 2023, 5 (01)
  • [23] Retrospective correction for T1-weighting bias in T2 values obtained with various spectroscopic spin-echo acquisition schemes
    Fleysher, Roman
    Fleysher, Lazar
    Kirov, Ivan
    Hess, David A.
    Liu, Songtao
    Gonen, Oded
    MAGNETIC RESONANCE IMAGING, 2009, 27 (10) : 1410 - 1419
  • [24] Simultaneous Quantitative MRI Mapping of T1, T2* and Magnetic Susceptibility with Multi-Echo MP2RAGE
    Metere, Riccardo
    Kober, Tobias
    Moeller, Harald E.
    Schaefer, Andreas
    PLOS ONE, 2017, 12 (01):
  • [25] Abdominal T2-Weighted Imaging and T2 Mapping Using a Variable Flip Angle Radial Turbo Spin-Echo Technique
    Keerthivasan, Mahesh B.
    Galons, Jean-Philippe
    Johnson, Kevin
    Umapathy, Lavanya
    Martin, Diego R.
    Bilgin, Ali
    Altbach, Maria, I
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (01) : 289 - 300
  • [26] Automated T1 and T2 mapping segmentation on cardiovascular magnetic resonance imaging using deep learning
    Kalapos, Andras
    Szabo, Liliana
    Dohy, Zsofia
    Kiss, Mate
    Merkely, Bela
    Gyires-Toth, Balint
    Vago, Hajnalka
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [27] Multi-parametric liver tissue characterization using MR fingerprinting: Simultaneous T1, T2, T2*, and fat fraction mapping
    Jaubert, Olivier
    Arrieta, Cristobal
    Cruz, Gastao
    Bustin, Aurelien
    Schneider, Torben
    Georgiopoulos, Georgios
    Masci, Pier-Giorgio
    Sing-Long, Carlos
    Botnar, Rene M.
    Prieto, Claudia
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (05) : 2625 - 2635
  • [28] Simultaneous T1 and T2 mapping of hyperpolarized 13C compounds using the bSSFP sequence
    Milshteyn, Eugene
    Reed, Galen D.
    Gordon, Jeremy W.
    von Morze, Cornelius
    Cao, Peng
    Tang, Shuyu
    Leynes, Andrew P.
    Larson, Peder E. Z.
    Vigneron, Daniel B.
    JOURNAL OF MAGNETIC RESONANCE, 2020, 312
  • [29] OPTIMIZATION OF SIGNAL-TO-NOISE RATIO IN CALCULATED T1 IMAGES DERIVED FROM 2 SPIN-ECHO IMAGES
    PRATO, FS
    DROST, DJ
    KEYS, T
    LAXON, P
    COMISSIONG, B
    SESTINI, E
    MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (01) : 63 - 75
  • [30] MRI T2 Mapping of the Knee Providing Synthetic Morphologic Images: Comparison to Conventional Turbo Spin-Echo MRI
    Roux, Marion
    Hilbert, Tom
    Hussami, Mahmoud
    Becce, Fabio
    Kober, Tobias
    Omoumi, Patrick
    RADIOLOGY, 2019, 293 (03) : 620 - 630