MS Lesions Are Better Detected with 3D T1 Gradient-Echo Than with 2D T1 Spin-Echo Gadolinium-Enhanced Imaging at 3T

被引:26
|
作者
Crombe, A. [1 ]
Saranathan, M. [3 ]
Ruet, A. [2 ,4 ]
Durieux, M. [1 ]
de Roquefeuil, E. [1 ]
Ouallet, J. C. [2 ]
Brochet, B. [2 ,4 ]
Dousset, V. [1 ,4 ]
Tourdias, T. [1 ,4 ]
机构
[1] CHU Bordeaux, Serv Neuroimagerie Diagnost & Therapeut, F-33076 Bordeaux, France
[2] CHU Bordeaux, Pole Neurosci Clin, F-33076 Bordeaux, France
[3] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[4] Univ Bordeaux, INSERM, U862, Neuroctr Magendie, Bordeaux, France
关键词
HIGH-FIELD MRI; MULTIPLE-SCLEROSIS; CONTRAST ENHANCEMENT; MP-RAGE; BRAIN; SEQUENCES; RECOMMENDATIONS; STRENGTH; SINGLE; SENSITIVITY;
D O I
10.3174/ajnr.A4152
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: In multiple sclerosis, gadolinium enhancement is used to classify lesions as active. Regarding the need for a standardized and accurate method for detection of multiple sclerosis activity, we compared 2D-spin-echo with 3D-gradient-echo T1WI or the detection of gadolinium-enhancing MS lesions. MATERIALS AND METHODS: Fifty-eight patients with MS were prospectively imaged at 31 by using both 2D-spin-echo and 3D-gradient recalled-echo T1WI in random order after the injection of gadolinium. Blinded and independent evaluation was performed by a junior and a senior reader to count gadolinium-enhancing lesions and to characterize their location, size, pattern of enhancement, and the relative contrast between enhancing lesions and the adjacent white matter. Finally, the SNR and relative contrast of gadolinium-enhancing lesions were computed for both sequences by using simulations. RESULTS: Significantly more gadolinium-enhancing lesions were reported on 3D-gradient recalled-echo than on 2D-spin-echo (n = 59 versus n = 30 for the junior reader, P = .021: n = 77 versus n = 61 for the senior reader, P = .017). The difference between the 2 readers was significant on 2D-spin-echo (P = .044), for which images were less reproducible (K = 0.51) than for 3D-gradient recalled-echo (rc = 0.65). Further comparisons showed that there were statistically more small lesions (<5 mm) on 3D-gradient recalled-echo than on 2D-spin-echo (P = .04), while other features were similar. Theoretic results from simulations predicted SNR and lesion contrast for 3D-gradient recalled-echo to be better than for 2D-spin-echo for visualization of small enhancing lesions and were, therefore, consistent with clinical observations. CONCLUSIONS: At 31, 3D-gradient recalled-echo provides a higher detection rate of gadolinium-enhancing lesions, especially those with smaller size, with a better reproducibility; this finding suggests using 3D-gradient recalled-echo to detect MS activity, with potential impact in initiation, monitoring, and optimization of therapy.
引用
收藏
页码:501 / 507
页数:7
相关论文
共 50 条
  • [1] T1ρ-prepared balanced gradient echo for rapid 3D t1ρ MRI
    Witschey, Walter R. T.
    Borthakur, Arijitt
    Elliott, Mark A.
    Fenty, Matthew
    Sochor, Matthew A.
    Wang, Chenyang
    Reddy, Ravinder
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (03) : 744 - 754
  • [2] Comparison between gadolinium-enhanced 2D T1-weighted gradient-echo and spin-echo sequences in the detection of active multiple sclerosis lesions on 3.0T MRI
    Aymerich, F. X.
    Auger, C.
    Alcaide-Leon, P.
    Pareto, D.
    Huerga, E.
    Corral, J. F.
    Mitjana, R.
    Sastre-Garriga, J.
    Montalban, X.
    Rovira, A.
    EUROPEAN RADIOLOGY, 2017, 27 (04) : 1361 - 1368
  • [3] Comparison between gadolinium-enhanced 2D T1-weighted gradient-echo and spin-echo sequences in the detection of active multiple sclerosis lesions on 3.0T MRI
    F. X. Aymerich
    C. Auger
    P. Alcaide-Leon
    D. Pareto
    E. Huerga
    J. F. Corral
    R. Mitjana
    J. Sastre-Garriga
    X. Montalban
    A. Rovira
    European Radiology, 2017, 27 : 1361 - 1368
  • [4] Diagnostic Utility of 3D Gradient-Echo MR Imaging Sequences through the Filum Compared with Spin-Echo T1 in Children with Concern for Tethered Cord
    Rafiee, F.
    Mehan, W. A.
    Rincon, S.
    Rohatgi, S.
    Rapalino, O.
    Buch, K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2023, 44 (03) : 323 - 327
  • [5] Magnetic resonance T1 gradient-echo imaging in hepatolithiasis
    F. Safar
    T. Kamura
    K. Okamuto
    K. Sasai
    F. Gejyo
    Abdominal Imaging, 2005, 30 : 297 - 302
  • [6] Magnetic resonance T1 gradient-echo imaging in hepatolithiasis
    Safar, F
    Kamura, T
    Okamuto, K
    Sasai, K
    Gejyo, F
    ABDOMINAL IMAGING, 2005, 30 (03): : 297 - 302
  • [7] Comparison of Spin-Echo and Gradient-Echo T1-Weighted and Spin-Echo T2-Weighted Images at 3T in Evaluating Term-Neonatal Myelination
    Tyan, A. E.
    McKinney, A. M.
    Hanson, T. J.
    Truwit, C. L.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (02) : 411 - 416
  • [8] MRI detection of hypointense brain lesions in patients with multiple sclerosis: T1 spin-echo vs. gradient-echo
    Dupuy, Sheena L.
    Tauhid, Shahamat
    Kim, Gloria
    Chu, Renxin
    Tummala, Subhash
    Hurwitz, Shelley
    Bakshi, Rohit
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (08) : 1564 - 1568
  • [9] Comparison of High Resolution Gradient Echo, XBONE T1, XBONE T2, Spin Echo T1 and 3D SST1 magnetic resonance imaging sequences for imagining the canine elbow
    Zhalniarovich, Y.
    Adamiak, Z.
    Glodek, J.
    Przyborowska, P.
    Holak, P.
    POLISH JOURNAL OF VETERINARY SCIENCES, 2014, 17 (04): : 587 - 591
  • [10] MRI OF THE PITUITARY-GLAND - SPIN-ECHO 2D OR GRADIENT-ECHO 3D
    REUTHER, G
    BONGARTZ, G
    FAHRENDORF, G
    PETERS, PE
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 154 (03): : 281 - 285