Accelerated Cardiac T2 Mapping using Breath-hold Multiecho Fast Spin-Echo Pulse Sequence with k-t FOCUSS

被引:70
|
作者
Feng, Li [2 ]
Otazo, Ricardo [1 ]
Jung, Hong [3 ]
Jensen, Jens H. [1 ]
Ye, Jong C. [3 ]
Sodickson, Daniel K. [1 ]
Kim, Daniel [1 ]
机构
[1] NYU, Dept Radiol, Sch Med, Ctr Biomed Imaging, New York, NY 10012 USA
[2] NYU, Sch Med, Sackler Inst Grad Biomed Sci, New York, NY USA
[3] Korea Adv Inst Sci & Technol, Dept Bio & Brain Engn, Bioimaging & Signal Proc Lab, Taejon 305701, South Korea
基金
美国国家卫生研究院;
关键词
MRI; heart; multiecho FSE; T-2; compressed sensing; parallel imaging; k-t FOCUSS; CARDIOVASCULAR MAGNETIC-RESONANCE; MYOCARDIAL-INFARCTION; MRI; HEART; EDEMA; SENSE;
D O I
10.1002/mrm.22756
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cardiac T-2 mapping is a promising method for quantitative assessment of myocardial edema and iron overload. We have developed a new multiecho fast spin echo (ME-FSE) pulse sequence for breath-hold T-2 mapping with acceptable spatial resolution. We propose to further accelerate this new ME-FSE pulse sequence using k-t focal underdetermined system solver adapted with a framework that uses both compressed sensing and parallel imaging (e. g., sensitivity encoding) to achieve higher spatial resolution. We imaged 12 control subjects in midventricular short-axis planes and compared the accuracy of T-2 measurements obtained using ME-FSE with generalized autocalibrating partially parallel acquisitions and ME-FSE with k-t focal underdetermined system solver. For image reconstruction, we used a bootstrapping two-step approach, where in the first step fast Fourier transform was used as the sparsifying transform and in the final step principal component analysis was used as the sparsifying transform. When compared with T-2 measurements obtained using generalized autocalibrating partially parallel acquisitions, T-2 measurements obtained using k-t focal underdetermined system solver were in excellent agreement (mean difference = 0.04 msec; upper/lower 95% limits of agreement were 2.26/-22.19 msec, respectively). The proposed accelerated ME-FSE pulse sequence with k-t focal underdetermined system solver is a promising investigational method for rapid T-2 measurement of the heart with relatively high spatial resolution (1.7 x 1.7 mm(2)). Magn Reson Med 65:1661-1669, 2011. (C) 2011 Wiley-Liss, Inc.
引用
收藏
页码:1661 / 1669
页数:9
相关论文
共 50 条
  • [1] Utility of breath-hold fast-recovery fast spin-echo T2 versus respiratory-triggered fast spin-echo T2 in clinical hepatic imaging
    Huang, J
    Raman, SS
    Vuong, N
    Sayre, JW
    Lu, DSK
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (03) : 842 - 846
  • [2] Breath-hold T2-weighted imaging of hepatic lesions by using fast recovery, fast spin-echo sequence
    Kim, T
    Murakami, T
    Takahashi, S
    Hori, M
    Takamura, M
    Nakamura, H
    RADIOLOGY, 2001, 221 : 304 - 305
  • [3] Quantitative assessment of myocardial edema using a breath-hold T2 mapping pulse sequence
    Mansi Shah
    Monvadi B Srichai
    Daniel Kim
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [4] Fast T2 Relaxometry with an Accelerated Multi-echo Spin-echo Sequence
    Senegas, Julien
    Liu, Wei
    Dahnke, Hannes
    Song, Hotaek
    Jordan, E. Kay
    Frank, Joseph A.
    NMR IN BIOMEDICINE, 2010, 23 (08) : 958 - 967
  • [5] T2-weighted spin-echo MR imaging of the liver: Breath-hold fast spin-echo versus non-breath-hold fast spin-echo images with and without fat suppression
    Soyer, P
    LeNormand, S
    deGivry, SC
    Gueye, C
    Somveille, E
    Scherrer, A
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (03) : 593 - 597
  • [6] Liver: T2-weighted MR imaging with breath-hold fast-recovery optimized fast spin-echo compared with breath-hold half-Fourier and non-breath-hold respiratory-triggered fast spin-echo pulse sequences
    Augui, J
    Vignaux, O
    Argaud, C
    Coste, J
    Gouya, H
    Legmann, P
    RADIOLOGY, 2002, 223 (03) : 853 - 859
  • [7] A short-TR single-echo spin-echo breath-hold method for assessing liver T2
    Sussman, Marshall S.
    Jhaveri, Kartik S.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2024, 37 (01) : 101 - 113
  • [8] A short-TR single-echo spin-echo breath-hold method for assessing liver T2
    Marshall S. Sussman
    Kartik S. Jhaveri
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2024, 37 : 101 - 113
  • [9] Fat-suppressed T2-weighted MRI of the liver: Comparison of respiratory-triggered fast spin-echo, breath-hold single-shot fast spin-echo, and breath-hold fast-recovery fast spin-echo sequences
    Katayama, M
    Masui, T
    Kobayashi, S
    Ito, T
    Takahashi, M
    Sakahara, H
    Nozaki, A
    Kabasawa, H
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (04) : 439 - 449
  • [10] Fat-suppressed T2-weighted MR imaging of the liver: Comparison of respiratory triggered fast spin-echo, breath-hold single-shot fast spin-echo and breath-hold fast-recovery fast spin-echo sequences
    Katayama, M
    Masui, T
    Kobayashi, S
    Ito, T
    Sakahara, H
    Nozaki, A
    RADIOLOGY, 2000, 217 : 587 - 587