Accelerated Cardiac T2 Mapping using Breath-hold Multiecho Fast Spin-Echo Pulse Sequence with k-t FOCUSS

被引:70
|
作者
Feng, Li [2 ]
Otazo, Ricardo [1 ]
Jung, Hong [3 ]
Jensen, Jens H. [1 ]
Ye, Jong C. [3 ]
Sodickson, Daniel K. [1 ]
Kim, Daniel [1 ]
机构
[1] NYU, Dept Radiol, Sch Med, Ctr Biomed Imaging, New York, NY 10012 USA
[2] NYU, Sch Med, Sackler Inst Grad Biomed Sci, New York, NY USA
[3] Korea Adv Inst Sci & Technol, Dept Bio & Brain Engn, Bioimaging & Signal Proc Lab, Taejon 305701, South Korea
基金
美国国家卫生研究院;
关键词
MRI; heart; multiecho FSE; T-2; compressed sensing; parallel imaging; k-t FOCUSS; CARDIOVASCULAR MAGNETIC-RESONANCE; MYOCARDIAL-INFARCTION; MRI; HEART; EDEMA; SENSE;
D O I
10.1002/mrm.22756
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cardiac T-2 mapping is a promising method for quantitative assessment of myocardial edema and iron overload. We have developed a new multiecho fast spin echo (ME-FSE) pulse sequence for breath-hold T-2 mapping with acceptable spatial resolution. We propose to further accelerate this new ME-FSE pulse sequence using k-t focal underdetermined system solver adapted with a framework that uses both compressed sensing and parallel imaging (e. g., sensitivity encoding) to achieve higher spatial resolution. We imaged 12 control subjects in midventricular short-axis planes and compared the accuracy of T-2 measurements obtained using ME-FSE with generalized autocalibrating partially parallel acquisitions and ME-FSE with k-t focal underdetermined system solver. For image reconstruction, we used a bootstrapping two-step approach, where in the first step fast Fourier transform was used as the sparsifying transform and in the final step principal component analysis was used as the sparsifying transform. When compared with T-2 measurements obtained using generalized autocalibrating partially parallel acquisitions, T-2 measurements obtained using k-t focal underdetermined system solver were in excellent agreement (mean difference = 0.04 msec; upper/lower 95% limits of agreement were 2.26/-22.19 msec, respectively). The proposed accelerated ME-FSE pulse sequence with k-t focal underdetermined system solver is a promising investigational method for rapid T-2 measurement of the heart with relatively high spatial resolution (1.7 x 1.7 mm(2)). Magn Reson Med 65:1661-1669, 2011. (C) 2011 Wiley-Liss, Inc.
引用
收藏
页码:1661 / 1669
页数:9
相关论文
共 50 条
  • [41] T2-weighted breath-hold MRI of the liver at 1.0 T: Comparison of turbo spin-echo and HASTE sequences with and without fat suppression
    Kim, TK
    Lee, HJ
    Jang, HJ
    Kim, AY
    Han, JK
    Choi, BI
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (06): : 1213 - 1218
  • [42] T2 mapping of the heart with a double-inversion radial fast spin-echo method with indirect echo compensation
    Hagio, Tomoe
    Huang, Chuan
    Abidov, Aiden
    Singh, Jaspreet
    Ainapurapu, Bujji
    Squire, Scott
    Bruck, Denise
    Altbach, Maria I.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
  • [43] T2 mapping of the heart with a double-inversion radial fast spin-echo method with indirect echo compensation
    Tomoe Hagio
    Chuan Huang
    Aiden Abidov
    Jaspreet Singh
    Bujji Ainapurapu
    Scott Squire
    Denise Bruck
    Maria I Altbach
    Journal of Cardiovascular Magnetic Resonance, 17
  • [44] Liver T2-weighted MR imaging: Comparison of fast and conventional half-Fourier single-shot turbo spin-echo, breath-hold turbo spin-echo, and respiratory-triggered turbo spin-echo sequences
    Tang, Y
    Yamashita, Y
    Namimoto, T
    Abe, Y
    Takahashi, M
    RADIOLOGY, 1997, 203 (03) : 766 - 772
  • [45] Analysis of artefacts and detail resolution of lung MRI with breath-hold T1-weighted gradient-echo and T2-weighted fast spin-echo sequences with respiratory triggering
    Biederer, J
    Reuter, M
    Both, M
    Muhle, C
    Grimm, J
    Graessner, J
    Heller, M
    EUROPEAN RADIOLOGY, 2002, 12 (02) : 378 - 384
  • [46] Analysis of artefacts and detail resolution of lung MRI with breath-hold T1-weighted gradient-echo and T2-weighted fast spin-echo sequences with respiratory triggering
    J. Biederer
    M. Reuter
    M. Both
    C. Muhle
    J. Grimm
    J. Graessner
    M. Heller
    European Radiology, 2002, 12 : 378 - 384
  • [47] Magnetic resonance fingerprinting for simultaneous renal T1 and T2*mapping in a single breath-hold
    Hermann, Ingo
    Chacon-Caldera, Jorge
    Brumer, Irene
    Rieger, Benedikt
    Weingartner, Sebastian
    Schad, Lothar R.
    Zoellner, Frank G.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (06) : 1940 - 1948
  • [48] COOPERATIVE T1 AND T2 EFFECTS ON CONTRAST USING A NEW DRIVEN INVERSION SPIN-ECHO (DISE) MRI PULSE SEQUENCE
    CONTURO, TE
    KESSLER, RM
    BETH, AH
    MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (03) : 397 - 419
  • [49] T2 shuffling: Sharp, multicontrast, volumetric fast spin-echo imaging
    Tamir, Jonathan I.
    Uecker, Martin
    Chen, Weitian
    Lai, Peng
    Alley, Marcus T.
    Vasanawala, Shreyas S.
    Lustig, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (01) : 180 - 195
  • [50] LIVER-BUDA-SAGE: SIMULTANEOUS WHOLE LIVER T2 AND T*2 MAPPING IN ONE BREATH-HOLD
    Zhang, Zijing
    Ye, Huihui
    Li, Maosen
    Liu, Huafeng
    Bilgic, Berkin
    2022 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (IEEE ISBI 2022), 2022,