Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Image-based correction of gantry motion nonidealities

被引:102
|
作者
Fahrig, R
Holdsworth, DW
机构
[1] Univ Western Ontario, Dept Med Biophys & Diagnost Radiol, London, ON N6A 5K8, Canada
[2] John P Robarts Res Inst, London, ON N6A 5K8, Canada
关键词
x-ray image intensifier; calibration of geometric parameters; conebeam volume imaging;
D O I
10.1118/1.598854
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The image quality of 3D reconstructions produced using a C-arm mounted XRII depends on precise determination of the geometric parameters that describe the detector system in the laboratory frame of reference. We have designed a simplified calibration system that depends on images of a metal sphere, acquired during rotation of the gantry through 200 degrees. Angle-dependent shift corrections ore obtained, accounting for nonideal motion in two directions: perpendicular to the axis of rotation and tangential to the circular trajectory (tau), and parallel to the axis of rotation (xi). projection images are corrected prior to reconstruction using a simple shift-interpolation algorithm. We show that the motion of the gantry is highly reproducible during acquisitions within one day (mean standard deviation in tau and xi is 0.11 mm and 0.08 mml respectively), and over 21 months (mean standard deviation in tau and xi is 0.10 mm and 0.06 mm, respectively). Reconstruction of a small-bead phantom demonstrates uniformity of the correction algorithm over the full volume of the reconstruction [standard deviation of full-width-half-maximum of the beads is similar to 0.25 pixels (0.13 nm) over the volume of reconstruction]. Our approach provides a simple correction technique that can be applied when trajectory deviations are significant relative to the pixel size of the detector but small relative to the detector field of view, and when the fan angle of the acquisition geometry is small (<20 degrees). A comparison with other calibration techniques in the literature is provided. (C) 2000 American Institute of Physics.
引用
收藏
页码:30 / 38
页数:9
相关论文
共 50 条
  • [1] Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Correction of image intensifier distortion
    Fahrig, R
    Moreau, M
    Holdsworth, DW
    MEDICAL PHYSICS, 1997, 24 (07) : 1097 - 1106
  • [2] Three-dimensional CT angiography from a clinical C-arm mounted XRII
    Fahrig, R
    Fox, AJ
    Holdsworth, DW
    RADIOLOGY, 1996, 201 : 879 - 879
  • [3] Characterization of a C-arm mounted XRII for 3D image reconstruction during interventional neuroradiology
    Fahrig, R
    Fox, AJ
    Holdsworth, DW
    PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 351 - 360
  • [4] Sparsity-constrained three-dimensional image reconstruction for C-arm angiography
    Rashed, Essam A.
    al-Shatouri, Mohammad
    Kudo, Hiroyuki
    COMPUTERS IN BIOLOGY AND MEDICINE, 2015, 62 : 141 - 153
  • [5] Three-dimensional reconstruction of high contrast objects using C-arm image intensifier projection data
    Grass, M
    Koppe, R
    Klotz, E
    Proksa, R
    Kuhn, MH
    Aerts, H
    Op de Beek, J
    Kemkers, R
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1999, 23 (06) : 311 - 321
  • [6] Compressed-sensing-based three-dimensional image reconstruction algorithm for C-arm vascular imaging
    Selim, Mona
    al-Shatouri, Mohammad
    Kudo, Hiroyuki
    Rashed, Essam A.
    2014 CAIRO INTERNATIONAL BIOMEDICAL ENGINEERING CONFERENCE (CIBEC), 2014, : 111 - 114
  • [7] Three-dimensional CT with a modified C-arm image intensifier: Feasibility
    Linsenmaier, U
    Rock, C
    Euler, E
    Wirth, S
    Brandl, R
    Kotsianos, D
    Mutschler, W
    Pfeifer, KJ
    RADIOLOGY, 2002, 224 (01) : 286 - 292
  • [8] Three-dimensional left atrial and oesophagus reconstruction using cardiac C-arm computed tomography for ablation of atrial fibrillation: Preliminary experience
    Noelker, Georg
    Marschang, Harald
    Gutleben, Klaus
    Ritscher, Guido
    Schmidt, Martin
    Sinha, Anil M.
    Rittger, Harald
    Marrouche, Nassir F.
    Brachmann, Johannes
    CIRCULATION, 2007, 116 (16) : 365 - 365
  • [9] Image reconstruction method based on backprojection filtration algorithm in C-arm computed tomography
    Wang, Xianchao
    Wu, Qilin
    Xu, Pan
    Lu, Zheng
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [10] Analysis of equine cervical spine using three-dimensional computed tomographic reconstruction
    Zafra, Rafael
    Carrascosa, Conrado
    Rivero, Miguel
    Pena, Sara
    Fernandez, Teresa
    Suarez-Bonnet, Alejandro
    Raduan Jaber, J.
    JOURNAL OF APPLIED ANIMAL RESEARCH, 2012, 40 (02) : 108 - 111