Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Image-based correction of gantry motion nonidealities

被引:102
|
作者
Fahrig, R
Holdsworth, DW
机构
[1] Univ Western Ontario, Dept Med Biophys & Diagnost Radiol, London, ON N6A 5K8, Canada
[2] John P Robarts Res Inst, London, ON N6A 5K8, Canada
关键词
x-ray image intensifier; calibration of geometric parameters; conebeam volume imaging;
D O I
10.1118/1.598854
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The image quality of 3D reconstructions produced using a C-arm mounted XRII depends on precise determination of the geometric parameters that describe the detector system in the laboratory frame of reference. We have designed a simplified calibration system that depends on images of a metal sphere, acquired during rotation of the gantry through 200 degrees. Angle-dependent shift corrections ore obtained, accounting for nonideal motion in two directions: perpendicular to the axis of rotation and tangential to the circular trajectory (tau), and parallel to the axis of rotation (xi). projection images are corrected prior to reconstruction using a simple shift-interpolation algorithm. We show that the motion of the gantry is highly reproducible during acquisitions within one day (mean standard deviation in tau and xi is 0.11 mm and 0.08 mml respectively), and over 21 months (mean standard deviation in tau and xi is 0.10 mm and 0.06 mm, respectively). Reconstruction of a small-bead phantom demonstrates uniformity of the correction algorithm over the full volume of the reconstruction [standard deviation of full-width-half-maximum of the beads is similar to 0.25 pixels (0.13 nm) over the volume of reconstruction]. Our approach provides a simple correction technique that can be applied when trajectory deviations are significant relative to the pixel size of the detector but small relative to the detector field of view, and when the fan angle of the acquisition geometry is small (<20 degrees). A comparison with other calibration techniques in the literature is provided. (C) 2000 American Institute of Physics.
引用
收藏
页码:30 / 38
页数:9
相关论文
共 50 条
  • [41] Three-dimensional human motion modeling by back-projection based on image-based camera calibration
    Satoru Masaoka
    Joo Kooi Tan
    Hyoungseop Kim
    Takashi Shinomiya
    Seiji Ishikawa
    Artificial Life and Robotics, 2009, 14 (4) : 515 - 518
  • [42] Texture-Mapping Error Removal Based on the BRIEF Operator in Image-Based Three-Dimensional Reconstruction
    Yang, Junxing
    Lu, Lu
    Peng, Ge
    Huang, He
    Wang, Jian
    Deng, Fei
    REMOTE SENSING, 2023, 15 (02)
  • [43] Three-dimensional human motion modeling by back-projection based on image-based camera calibration
    Masaoka, Satoru
    Tan, Joo
    Kim, Hyoungseop
    Shinomiya, Takashi
    Ishikawa, Seiji
    ARTIFICIAL LIFE AND ROBOTICS, 2009, 14 (04) : 515 - 518
  • [44] Quantitative Analysis of the Cochlea using Three-Dimensional Reconstruction based on Microcomputed Tomographic Images
    Shin, Kang-Jae
    Lee, Ju-Young
    Kim, Jeong-Nam
    Yoo, Ja-Young
    Shin, Chuog
    Song, Wu-Chul
    Koh, Ki-Seok
    ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2013, 296 (07): : 1083 - 1088
  • [45] Three-dimensional quantification of soil hydraulic properties using X-ray Computed Tomography and image-based modeling
    Tracy, Saoirse R.
    Daly, Keith R.
    Sturrock, Craig J.
    Crout, Neil M. J.
    Mooney, Sacha J.
    Roose, Tiina
    WATER RESOURCES RESEARCH, 2015, 51 (02) : 1006 - 1022
  • [46] Image-based three-dimensional model reconstruction for Chinese treasure-Jadeite Cabbage with Insects
    Cheng, Chia-Ming
    Wang, Shu-Fan
    Teng, Chin-Hung
    Lai, Shang-Hong
    COMPUTERS & GRAPHICS-UK, 2008, 32 (06): : 682 - 694
  • [47] Three-dimensional reconstruction imaging by C-arm computed tomography accurately visualizes in-stent neointimal formation in patients with stent-assisted coil embolization
    Kotsugi, Masashi
    Nakagawa, Ichiro
    Konishi, Kengo
    Tanaka, Haku
    Sasaki, Hiromitsu
    Furuta, Takanori
    Okamoto, Ai
    Nakase, Kenta
    Maeoka, Ryosuke
    Yokoyama, Shohei
    Yamada, Shuichi
    Nakase, Hiroyuki
    FRONTIERS IN NEUROLOGY, 2023, 14
  • [48] Three-dimensional motion correction using speckle and phase for in vivo computed optical interferometric tomography
    Shemonski, Nathan D.
    Ahn, Shawn S.
    Liu, Yuan-Zhi
    South, Fredrick A.
    Carney, P. Scott
    Boppart, Stephen A.
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (12): : 4131 - 4143
  • [49] Image-based Compensation for Involuntary Motion in Weight-bearing C-arm Cone-beam CT Scanning of Knees
    Unberath, Mathias
    Choi, Jang-Hwan
    Berger, Martin
    Maier, Andreas
    Fahrig, Rebecca
    MEDICAL IMAGING 2015: IMAGE PROCESSING, 2015, 9413
  • [50] Feasibility of a new C-arm angiography (DYNA-CT) based three-dimensional coronary reconstruction algorithm in combination with myocardial perfusion assessment
    Rittger, H.
    Rohkohl, C.
    Lauritsch, G.
    Sinha, A.
    Rieber, J.
    Brachmann, J.
    EUROPEAN HEART JOURNAL, 2011, 32 : 349 - 349