Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Image-based correction of gantry motion nonidealities

被引:102
|
作者
Fahrig, R
Holdsworth, DW
机构
[1] Univ Western Ontario, Dept Med Biophys & Diagnost Radiol, London, ON N6A 5K8, Canada
[2] John P Robarts Res Inst, London, ON N6A 5K8, Canada
关键词
x-ray image intensifier; calibration of geometric parameters; conebeam volume imaging;
D O I
10.1118/1.598854
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The image quality of 3D reconstructions produced using a C-arm mounted XRII depends on precise determination of the geometric parameters that describe the detector system in the laboratory frame of reference. We have designed a simplified calibration system that depends on images of a metal sphere, acquired during rotation of the gantry through 200 degrees. Angle-dependent shift corrections ore obtained, accounting for nonideal motion in two directions: perpendicular to the axis of rotation and tangential to the circular trajectory (tau), and parallel to the axis of rotation (xi). projection images are corrected prior to reconstruction using a simple shift-interpolation algorithm. We show that the motion of the gantry is highly reproducible during acquisitions within one day (mean standard deviation in tau and xi is 0.11 mm and 0.08 mml respectively), and over 21 months (mean standard deviation in tau and xi is 0.10 mm and 0.06 mm, respectively). Reconstruction of a small-bead phantom demonstrates uniformity of the correction algorithm over the full volume of the reconstruction [standard deviation of full-width-half-maximum of the beads is similar to 0.25 pixels (0.13 nm) over the volume of reconstruction]. Our approach provides a simple correction technique that can be applied when trajectory deviations are significant relative to the pixel size of the detector but small relative to the detector field of view, and when the fan angle of the acquisition geometry is small (<20 degrees). A comparison with other calibration techniques in the literature is provided. (C) 2000 American Institute of Physics.
引用
收藏
页码:30 / 38
页数:9
相关论文
共 50 条
  • [21] Evaluation of interpolation methods for surface-based motion compensated tomographic reconstruction for cardiac angiographic C-arm data
    Mueller, Kerstin
    Schwemmer, Chris
    Hornegger, Joachim
    Zheng, Yefeng
    Wang, Yang
    Lauritsch, Guenter
    Rohkohl, Christopher
    Maier, Andreas K.
    Schultz, Carl
    Fahrig, Rebecca
    MEDICAL PHYSICS, 2013, 40 (03)
  • [22] Preliminary outcomes of the surgical navigation system combined with intraoperative three-dimensional C-arm computed tomography for zygomatico-orbital fracture reconstruction
    Chu, Yu-Ying
    Yang, Jia-Ruei
    Lai, Bo-Ru
    Liao, Han-Tsung
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [23] Three-Dimensional Left Atrial and Oesophagus Reconstruction Using Cardiac C-Arm Computed Tomography with Image Integration into Fluoroscopic Views for Ablation of Atrial Fibrillation: Accuracy of a Novel Modality in Comparison to Multislice Computed Tomography.
    Noelker, Georg
    Sinha, Anil
    Gutleben, Klaus Juergen
    Ritscher, Guido
    Marschang, Harald
    Schmidt, Martin
    Rittger, Harald
    Marrouche, Nassir
    Brachmann, Johannes
    CIRCULATION, 2008, 118 (18) : S1006 - S1006
  • [24] Preliminary outcomes of the surgical navigation system combined with intraoperative three-dimensional C-arm computed tomography for zygomatico-orbital fracture reconstruction
    Yu-Ying Chu
    Jia-Ruei Yang
    Bo-Ru Lai
    Han-Tsung Liao
    Scientific Reports, 12
  • [25] Three-Dimensional Cholangiography Applying C-arm Computed Tomography in Bile Duct Carcinoma: A New Radiological Technique
    Nanashima, Atsushi
    Abo, Takafumi
    Sakamoto, Ichirou
    Makino, Kenji
    Sumida, Yorihisa
    Sawai, Terumitsu
    Nagayasu, Takeshi
    HEPATO-GASTROENTEROLOGY, 2009, 56 (91-92) : 615 - 618
  • [26] Three-dimensional C-arm computed tomography reformation combined with fluoroscopic-guided sacroplasty for sacral metastases
    Gang Sun
    Peng Jin
    Min Li
    Xun-wei Liu
    Fan-dong Li
    Supportive Care in Cancer, 2012, 20 : 2083 - 2088
  • [27] Three-dimensional C-arm computed tomography reformation combined with fluoroscopic-guided sacroplasty for sacral metastases
    Sun, Gang
    Jin, Peng
    Li, Min
    Liu, Xun-wei
    Li, Fan-dong
    SUPPORTIVE CARE IN CANCER, 2012, 20 (09) : 2083 - 2088
  • [28] Optimal C-arm angulation during transcatheter aortic valve replacement: Accuracy of a rotational C-arm computed tomography based three dimensional heart model
    Veulemans, Verena
    Mollus, Sabine
    Saalbach, Axel
    Pietsch, Max
    Hellhammer, Katharina
    Zeus, Tobias
    Westenfeld, Ralf
    Weese, Juergen
    Kelm, Malte
    Balzer, Jan
    WORLD JOURNAL OF CARDIOLOGY, 2016, 8 (10): : 606 - 614
  • [29] Three-Dimensional Angiography Using Mobile C-Arm with IMU Sensor Attached: Initial Study
    Moataz, Amr
    Soliman, Ahmed
    Ghanem, Ahmed M.
    al-Shatouri, Mohammad
    Atia, Ayman
    Rashed, Essam A.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [30] Three-dimensional image-based numerical homogenisation using octree meshes
    Saputra, Albert A.
    Eisentraeger, Sascha
    Gravenkamp, Hauke
    Song, Chongmin
    COMPUTERS & STRUCTURES, 2020, 237